{"product_id":"bently-nevada-330730-040-01-05-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-040-01-05 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330730-040-01-05\u003c\/strong\u003e specifies this 3300 XL 11 mm extension cable configuration, featuring a 4.0 meter cable length, protective stainless steel armor, and a multiple agency approvals package. This cable is used within the 3300 XL 11 mm Proximity Transducer System, connecting the 3300 XL 11 mm proximity probe to the 3300 XL 11 mm Proximitor sensor for non-contact shaft vibration, axial position, and differential expansion monitoring.\u003c\/p\u003e\n\u003cp\u003eCompared to standard non-armored models like the 330730-040-00-05, this configuration incorporates flexible AISI 302 stainless steel armor with an outer FEP jacket to withstand mechanical abrasion, physical impact, and harsh industrial environments. While unarmored configurations are lighter and more flexible for clean environments, the armored jacket is essential in open industrial installations where cables are routed near sharp edges or high-traffic areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4.0 meter cable length (Option 040) designed to combine with a 1.0 meter probe to achieve a 5.0 meter total system length.\u003c\/li\u003e\n  \u003cli\u003eAISI 302 stainless steel armor (Option 01) with an outer FEP jacket for mechanical protection against abrasion and physical impacts.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass coaxial connectors providing secure, low-loss electrical contact.\u003c\/li\u003e\n  \u003cli\u003eMultiple agency approvals (Option 05) supporting cNRTLus, ATEX, and IECEx certifications for hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003eTriaxial 75 ohm cable construction with fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n  \u003cli\u003e25.4 mm (1.0 in) minimum bend radius allowing flexible routing in tight conduits and enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical application environments include rotating machinery protection in heavy industries such as oil and gas, power generation, petrochemicals, and water treatment:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial thrust position monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor rotor position and casing differential expansion measurements.\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod drop and rod position tracking.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft runout and zero-speed monitoring.\u003c\/li\u003e\n  \u003cli\u003eBalance of plant rotating machinery protection in hazardous area environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Manufacturer Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330730-040-01-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eArmored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (cNRTLus, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330730-040-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 SST with FEP outer jacket (armored cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Material\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCore dc Resistance\u003c\/td\u003e\n      \u003ctd\u003e0.3 +\/- 0.1 ohms (center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eJacket dc Resistance\u003c\/td\u003e\n      \u003ctd\u003e1.0 +\/- 0.25 ohms (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Torque\u003c\/td\u003e\n      \u003ctd\u003eRecommended: finger tight; Maximum: 0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnit Weight\u003c\/td\u003e\n      \u003ctd\u003e140 g\/m (1.5 oz\/ft) for armored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eMates with 3300 XL 11 mm proximity probe coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eMates with 3300 XL 11 mm Proximitor sensor coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eKeep the minimum bend radius of the armored cable to 25.4 mm (1.0 in) or greater during routing to prevent core damage.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten coaxial connectors to ensure proper electrical mating; do not exceed the maximum torque limit of 0.565 N-m (5 in-lb).\u003c\/li\u003e\n  \u003cli\u003eProtect the connector junction using connector protectors or self-fusing silicone tape to prevent oil, moisture, and dust ingress.\u003c\/li\u003e\n  \u003cli\u003eDo not use silicone tape in environments where the cable connection will be directly exposed to turbine oil.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the sum of the extension cable length and the probe length matches the total length rated on the Proximitor sensor (e.g., 4.0 m cable + 1.0 m probe equals a 5.0 m system).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU, Standards EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU with China RoHS EFUP designation of 15 years\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT=0), SIL 3 (HFT=1) certified when used in a complete safety-instrumented system\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals (Option 05):\n    \u003cul\u003e\n      \u003cli\u003ecNRTLus (Intrinsically Safe): Class I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n      \u003cli\u003ecNRTLus (Non-incendive): Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n      \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga (EPL Ga), Ex ia IIIC T90C...T280C Dc (EPL Dc), Ex nA\/ec IIC T5...T1 Gc (EPL Gc)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528399723,"sku":"330730-040-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-040-01-05-extension-cable-5ycpb2ud2io_f89520df-dbca-4e81-8b28-ab3a929576a8.jpg?v=1765440313","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330730-040-01-05-3300-xl-11-mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}