{"product_id":"bently-nevada-330851-06-000-070-10-00-05-3300-xl-25-mm-proximity-probe","title":"Sonda de Proximidade Bently Nevada 330851-06-000-070-10-00-05 3300 XL 25 mm","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 06 (M39x1.5 metric thread), Option 000 (0 mm unthreaded length), and Option 070 (70 mm case length) specify the physical build of the \u003cstrong\u003e330851-06-000-070-10-00-05\u003c\/strong\u003e, a \u003cstrong\u003e3300 XL 25 mm proximity probe\u003c\/strong\u003e engineered for large-target differential expansion and axial displacement measurements.\u003c\/p\u003e\n\u003cp\u003eUnlike standard-profile probe variants utilizing smaller English threads (such as the 1-1\/2-12 thread under Option 01) or standard metric threads (like the M30x2 thread under Option 02), this configuration employs a robust M39x1.5 metric thread with a 45 mm lock nut and 36 mm wrench flats. Furthermore, this probe is supplied with a 1.0-meter non-armored FluidLoc triaxial cable (Option 10 and Option 00) and carries multiple hazardous area agency approvals (Option 05) for compatibility with critical machinery protection systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 06 case style provides a metric M39x1.5 thread, supplied with a 45 mm lock nut and 36 mm wrench flats.\u003c\/li\u003e\n  \u003cli\u003eOption 000 indicates a fully threaded case length with 0 mm of unthreaded length.\u003c\/li\u003e\n  \u003cli\u003eOption 070 provides a 70 mm overall case length for precise positioning in machinery housings.\u003c\/li\u003e\n  \u003cli\u003eOption 10 supplies a 1.0-meter (3.3 feet) FluidLoc triaxial probe cable with PFA insulation.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies a non-armored cable configuration for standard conduit routing.\u003c\/li\u003e\n  \u003cli\u003eOption 05 offers multiple international hazardous area certifications including CSA, ATEX, and IECEx.\u003c\/li\u003e\n  \u003cli\u003ePEEK (polyetheretherketone) probe tip provides robust chemical resistance and electrical isolation.\u003c\/li\u003e\n  \u003cli\u003eAISI 304 stainless steel case material delivers long-term corrosion resistance.\u003c\/li\u003e\n  \u003cli\u003eMiniature male coaxial connector provides secure, low-loss connections to the extension cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine differential expansion (DE) monitoring on mid-size to large power generation units.\u003c\/li\u003e\n  \u003cli\u003eNon-contact axial shaft displacement and shaft position monitoring.\u003c\/li\u003e\n  \u003cli\u003eRotor position and thrust bearing wear measurement on heavy industrial machinery.\u003c\/li\u003e\n  \u003cli\u003eLarge-target displacement measurements requiring extended linear range (12.7 mm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330851-06-000-070-10-00-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Probe, M39x1.5 thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe Case Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eM39x1.5 thread (Metric case, standard mount with 45 mm lock nut and 36 mm wrench flats)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e070\u003c\/td\u003e\n      \u003ctd\u003e70 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 metre (3.3 feet) total cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo armor (standard PFA insulated FluidLoc cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eF - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330851-06-000-070-10-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Thread Type\u003c\/td\u003e\n      \u003ctd\u003eMetric M39x1.5 thread (Option 06)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLock Nut and Flats\u003c\/td\u003e\n      \u003ctd\u003eSupplied with 45 mm lock nut and 36 mm wrench flats\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Case Length\u003c\/td\u003e\n      \u003ctd\u003e0 mm (Option 000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e70 mm (Option 070)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Probe Cable Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 metre (3.3 feet) (Option 10)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Armor Option\u003c\/td\u003e\n      \u003ctd\u003eNo armor (standard PFA jacket FluidLoc cable) (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e12.7 mm (500 mils) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range Boundaries\u003c\/td\u003e\n      \u003ctd\u003eStarts at approximately 0.63 mm (25 mils) to 13.33 mm (525 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n      \u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDSL Deviation (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Minimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e61 mm (2.4 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Frequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical with up to 305 m \/ 1000 ft field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe DC Resistance\u003c\/td\u003e\n      \u003ctd\u003e6.2 +\/- 0.5 Ohms (Center conductor to outer conductor R_PROBE)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyetheretherketone (PEEK)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 Stainless Steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Construction\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, perfluoroalkoxyethylene (PFA) insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range (Probe\/Cable)\u003c\/td\u003e\n      \u003ctd\u003e-55 to +177 degC (-67 to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Probe Case to Lead)\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Lead to Extension Cable)\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 lb) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Torque (M39x1.5 Thread)\u003c\/td\u003e\n      \u003ctd\u003eRecommended: 68 N-m (50 ft-lb); Maximum: 163 N-m (120 ft-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector-to-Connector Torque\u003c\/td\u003e\n      \u003ctd\u003eFinger tight recommended; 0.565 N-m (5 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Cable Length Compatibility\u003c\/td\u003e\n      \u003ctd\u003eMust equal total system length of 5.0 m or 9.0 m when paired with 330854 extension cable and 330850 Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCoaxial Connection\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eRF Signal path\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Conductor\u003c\/td\u003e\n      \u003ctd\u003eShield and Ground Return\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish safe and proper transducer operation, observe these mounting guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Size:\u003c\/strong\u003e Ensure the target flat surface is at least 61 mm (2.4 in) in diameter. Smaller target dimensions can restrict the linear range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Tighten the probe case to a recommended torque of 68 N-m (50 ft-lb). Do not exceed the maximum rated limit of 163 N-m (120 ft-lb). Always utilize the supplied 45 mm lock nut.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Seal all connector joints using silicone self-fusing tape to protect connections from moisture and oil contamination.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Avoid tight routing of the FluidLoc coaxial cable; preserve a minimum bend radius of 25.4 mm (1.0 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length Match:\u003c\/strong\u003e Pair the 1.0-meter probe cable with a complementary extension cable to reach exactly 5.0 m or 9.0 m, matching the Proximitor Sensor's designed system length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis transducer is approved under multiple hazardous area certification packages (Option 05), including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with all relevant European Union electromagnetic and safety directives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Intrinsically Safe):\u003c\/strong\u003e Ex ia IIC T5...T1 Ga for hazardous explosive environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Non-Sparking\/Increased Safety):\u003c\/strong\u003e Ex nA IIC T5...T1 Gc and Ex ec IIC T5...T1 Gc for Zone 2 applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American Classifications (CSA):\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American Class I Zone 2:\u003c\/strong\u003e AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851328363,"sku":"330851-06-000-070-10-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330851-06-000-070-10-00-05-proximity-probe-kj4eaild0pl_0c4638d0-8bfd-44a2-8bea-8de2a8f1316f.jpg?v=1765449052","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330851-06-000-070-10-00-05-3300-xl-25-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}