{"product_id":"bently-nevada-330881-28-00-214-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-00-214-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330881-28-00-214-00-02\u003c\/strong\u003e is a metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly featuring an integrated 3300 XL 8 mm proximity probe configured with Multiple Approvals, a 214 mm probe penetration length, and a 3\/4-14 NPT mounting thread. Unlike configuration options with standard unapproved probes, this specialized version integrates both the transducer probe and the Proximitor sensor into a single, self-contained plastic housing. This cohesive design eliminates the need for an intermediate extension cable, as well as a separate Proximitor sensor housing, allowing field wiring to connect directly from your monitoring system to the assembly cover.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for high durability in severe environments, the housing is molded from glass-reinforced, ultraviolet-resistant polyphenylene sulfide (PPS) thermoplastic. This advanced material incorporates conductive fibers to maximize mechanical strength while effectively dissipating electrostatic charges. Rated for Type 4X and IP66 conditions, this self-contained transducer system provides excellent resistance against moisture, dust, and corrosive industrial atmospheres, making it ideal for critical rotating machinery protection.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect Monitor Wiring: Self-contained assembly routes field connections directly to monitors, eliminating intermediate extension cables.\u003c\/li\u003e\n  \u003cli\u003eAdvanced PPS Thermoplastic: Glass-reinforced housing material offers high mechanical strength and effective electrostatic dissipation.\u003c\/li\u003e\n  \u003cli\u003eCustom 214 mm Penetration: Precise C-dimension metric sleeve length of 214 mm accommodates deep-set mounting configurations.\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Protection: Certified for Type 4X and IP66 environments, ensuring seal integrity against hose-directed water.\u003c\/li\u003e\n  \u003cli\u003eFlexible Adjustment: Threaded sleeve design allows plus-or-minus 12.7 mm of physical probe gap adjustment from the mid-setting point.\u003c\/li\u003e\n  \u003cli\u003eMultiple Agency Approvals: Pre-certified under option 28 for cNRTLus, ATEX, and IECEx hazardous area applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous radial vibration and axial position tracking on steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n  \u003cli\u003eIndustrial installations requiring simplified field wiring and reduced remote junction boxes.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection applications in highly corrosive, wet, or severe chemical process environments.\u003c\/li\u003e\n  \u003cli\u003eHigh-density machinery arrays where space limitations prevent mounting separate Proximitor housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e214\u003c\/td\u003e\n      \u003ctd\u003e214 mm probe penetration length (C dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; supplied with two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-00-214-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eO-Ring Material (Sleeve)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing and Sensor Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66 (BASEEFA and CSA verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrounding Protocol: Verify the integrated stainless steel grounding liner and retaining plate are connected properly to structural earth.\u003c\/li\u003e\n  \u003cli\u003eAdjustment Range: Leverage the outer sleeve thread to perform final adjustments of up to plus-or-minus 12.7 mm from your target surface.\u003c\/li\u003e\n  \u003cli\u003eWiring Precautions: Seal conduit pathways carefully during commissioning to prevent moisture from traveling down field cables into the housing.\u003c\/li\u003e\n  \u003cli\u003eTorque Requirements: Secure the retaining nut to a maximum of 29.5 N-m (260 in-lb), and the probe sleeve locknut to a maximum of 39.3 N-m (350 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx Certifications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ecNRTLus Certifications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEuropean Directives\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEMC Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4); RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUi = -28 V, Ii = 140 mA, Pi = 0.91 W, Ci = 1.5 nF, Li = 610 uH\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746732907,"sku":"330881-28-00-214-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-00-214-00-02-proxpac-xl-proximity-transducer-u21cormwsff_ef7dd5d5-4f76-4417-b5d9-8b74d2e5dcff.jpg?v=1765446960","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330881-28-00-214-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}