{"product_id":"bently-nevada-330881-28-05-070-00-02-proxpac-xl-proximity-transducer","title":"Transdutor de Proximidade PROXPAC XL Bently Nevada 330881-28-05-070-00-02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-05-070-00-02\u003c\/strong\u003e: PROXPAC XL Proximity Transducer assembly featuring a metric housing equipped with a 3300 XL 8 mm proximity probe (Multiple Approvals), a 50 mm standoff adapter, 70 mm probe penetration, standard plugs and washers, and 3\/4-14 NPT mounting thread.\u003c\/p\u003e\n\u003cp\u003eThis integrated configuration consolidates a 3300 XL 8 mm probe and a 3300 XL Proximitor sensor directly within a single glass-reinforced polyphenylene sulfide (PPS) thermoplastic housing. By eliminating the necessity for a separate extension cable and isolated Proximitor housing, this setup facilitates direct connection between the machinery monitors and the transducer assembly, simplifying the electrical wiring topology.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric housing design constructed of molded glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers for electrostatic dissipation.\u003c\/li\u003e\n  \u003cli\u003eOption 28 integration featuring a 3300 XL 8 mm proximity probe with multiple hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 05 providing a 50 mm standoff adapter (B dimension) for local standoff installation.\u003c\/li\u003e\n  \u003cli\u003eOption 070 specifying a 70 mm probe penetration length (C dimension) into the machine housing.\u003c\/li\u003e\n  \u003cli\u003eOption 00 fittings option supplying a kit of two conduit port plugs and two washers without extra fittings.\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting thread option supplying a 3\/4-14 NPT outer sleeve assembly thread.\u003c\/li\u003e\n  \u003cli\u003eDirect proximity probe and sensor integration to eliminate intermediate extension cables.\u003c\/li\u003e\n  \u003cli\u003eEnvironmental protection rating of IP66 and NEMA Type 4X for high-exposure environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration monitoring on rotating machines such as utility turbines, compressors, and large industrial pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial shaft position measurement for steam and gas turbine packages.\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery protection where a self-contained local transducer housing is required to reduce external cabling.\u003c\/li\u003e\n  \u003cli\u003eSevere industrial environments requiring protection against corrosive chemical contact, hot water, or steam.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-28-05-070-00-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals (ATEX\/IECEx\/CSA\/TR CU)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e50 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e070\u003c\/td\u003e\n      \u003ctd\u003e70 mm probe penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required for standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter Category\u003c\/th\u003e\n      \u003cth\u003eSpecification Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-05-070-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 Ohm +\/- 0.50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at 0.25 mm (10 mils) from target to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over the 80 mil linear range (0 degC to +45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) with components at 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1-metre length, 75 Ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) between probe cable and case, maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material \u0026amp; Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing\/Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Ingress Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and NEMA Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Retaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Probe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Tighten the retaining nut to 29.5 N-m (260 in-lb) and the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain secure position and sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Setting:\u003c\/strong\u003e Calibrate the probe to the midpoint of the linear range at 1.27 mm (50 mils) using a digital voltmeter measuring the DC voltage output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Connection:\u003c\/strong\u003e When using flexible conduit, order with integral fittings; seal any unused conduit holes using the supplied blanking plugs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Check the Neoprene sleeve O-ring and Viton internal probe O-ring during assembly to prevent ingress of oil or moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc for explosive gas and dust atmospheres (Option 28).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (CSA):\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP66 housing rating verified by BASEEFA and NEMA Type 4X enclosure rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with applicable European Union directives for electromagnetic compatibility and hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666743685483,"sku":"330881-28-05-070-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-05-070-00-02-proxpac-xl-proximity-transducer-ai3imwqz2xk_533ffac8-e298-4d3c-ab5b-e23b94282085.jpg?v=1765446930","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330881-28-05-070-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}