{"product_id":"bently-nevada-330881-28-10-060-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-10-060-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330881-28-10-060-03-02\u003c\/strong\u003e is a metric-configured \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly featuring a 3300 XL 8 mm proximity probe with Multiple Approvals, a 100 mm standoff adapter length, and a 60 mm probe penetration sleeve length. Unlike typical configuration variants that require separate external extension cables and standalone Proximitor sensors, this self-contained design integrates its own 3300 XL Proximitor sensor directly into the polyphenylene sulfide (PPS) cover of the housing. This integration saves valuable cabinet space and eliminates the risks associated with coaxial connector exposure on the factory floor.\u003c\/p\u003e\n\n\u003cp\u003eThis specialized machinery protection system provides reliable shaft vibration, position, and speed monitoring in highly demanding industrial settings. The structural body is manufactured from advanced thermoplastic molded with glass and conductive fibers to dissipate electrostatic charges. Engineered with a Type 4X and IP66 ingress protection rating, the housing ensures the internal electronics are sealed against moisture, dust, and corrosive vapors common in chemical plants, refineries, and cooling towers.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Cover\u003c\/strong\u003e: Internal 3300 XL Proximitor sensor eliminates the need for an external extension cable and dedicated sensor enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified (Option 28)\u003c\/strong\u003e: Pre-installed 3300 XL 8 mm probe meets strict Multiple Approvals requirements (including ATEX, IECEx, and CSA) for Zone 0, Zone 1, and Zone 2 installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetric Standoff and Penetration (Option 10 and 060)\u003c\/strong\u003e: Configured with a 100 mm standoff adapter and a 60 mm probe sleeve to allow external dial-in probe gap adjustment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Housing\u003c\/strong\u003e: Advanced PPS thermoplastic casing with conductive fibers offers chemical resistance and high structural impact durability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eM20 Conduit Integration (Option 03)\u003c\/strong\u003e: Supplied with a kit containing one M20 conduit fitting and two plugs for clean, watertight routing of field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThreaded Mount (Option 02)\u003c\/strong\u003e: Includes standard 3\/4-14 NPT mounting thread options for robust mechanical casing integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial thrust position measurements on high-speed industrial compressors.\u003c\/li\u003e\n  \u003cli\u003eCorrosive or high-humidity environments, including cooling tower fans and marine propulsion systems.\u003c\/li\u003e\n  \u003cli\u003eSteam turbine casing and industrial gearbox mechanical protection chains.\u003c\/li\u003e\n  \u003cli\u003eRemote machinery setups where minimizing cable run junctions and external hardware footprint is critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-10-060-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals (ATEX, IECEx, CSA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm Standoff Adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm Probe Penetration sleeve length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 conduit fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (tested with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Locknut Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 and 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeals and O-Rings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene sleeve O-ring, Viton internal probe seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when sealed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eConnection Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVoltage Supply\u003c\/td\u003e\n      \u003ctd\u003eConnects to -24 Vdc monitor power supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003eConnects to monitor dynamic signal input (-200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon\u003c\/td\u003e\n      \u003ctd\u003eConnects to system common return reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSleeve Gap Adjustment\u003c\/strong\u003e: Adjust the physical probe gap by loosening the outer sleeve locknut (recommended torque 39.3 N-m \/ 350 in-lb) and sliding the sleeve. Tighten once the gap voltage measures -10 Vdc (approx. 1.27 mm \/ 50 mils) on the target surface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Cable Specifications\u003c\/strong\u003e: Use 3-conductor, twisted shielded field wire (typically 18 AWG \/ 1.0 mm2) to connect the cover terminal block to the rack monitors. Connect the shield at the monitor common terminal only.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Prevention\u003c\/strong\u003e: Provide a drip loop in the flexible conduit immediately prior to the M20 conduit entries (Option 03) to prevent condensation or washdown water from flowing into the plastic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC\u003c\/strong\u003e: EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: Compliant with European Union Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: IP66 rated under BASEEFA report T07\/0709 and Type 4X verified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Areas (Option 28)\u003c\/strong\u003e: Certified for ATEX\/IECEx Zone 0 (Ex ia IIC T4\/T5 Ga) and CSA Class I, Div 1\/Zone 0 with safety barriers; certified for Zone 2 (Ex nA\/Ex ec IIC T4\/T5 Gc) without barriers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666762035563,"sku":"330881-28-10-060-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-10-060-03-02-proxpac-xl-proximity-transducer-h3zt5io1rd5_065b1c45-5937-4e9b-9008-11195380c09e.jpg?v=1765447132","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330881-28-10-060-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}