{"product_id":"bently-nevada-330881-28-11-214-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-11-214-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-11-214-00-02\u003c\/strong\u003e specifies a metric PROXPAC XL integrated transducer configured with a 3300 XL 8 mm proximity probe with multiple hazardous area approvals (Option 28), a 110 mm standoff adapter (Option 11), a 214 mm probe penetration length (Option 214), no conduit fittings (Option 00), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\u003cp\u003eThe PROXPAC XL Proximity Transducer Assembly integrates a 3300 XL 8 mm proximity probe and a 1-meter Proximitor sensor into a single, self-contained, protective housing. This design eliminates the need for an extension cable between the probe and Proximitor, as well as a separate external Proximitor enclosure, allowing field wiring to connect directly from the monitor to the PROXPAC XL terminal blocks.\u003c\/p\u003e\n\u003cp\u003eUnlike other configurations in the 330881 metric series which may use non-approved probes (Option 16) or contain no probe at all (Option 00 or 01), this variant comes standard with the multiple-approval certified 3300 XL 8 mm probe. While alternative designs may omit the standoff adapter (Option 00) or feature customized conduit fittings such as PG21 or M25 options, this assembly is configured with a 110 mm standoff length, standard 3\/4-14 NPT thread, and blanking plugs to seal the housing when external fittings are not required. The housing cover of the PROXPAC XL is made of glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers to strengthen the assembly and dissipate electrostatic charge, offering Type 4X and IP66 environmental protection.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 28: Integrated 3300 XL 8 mm proximity probe with multiple international hazardous area certifications (ATEX, IECEx, and North American approvals).\u003c\/li\u003e\n\u003cli\u003eOption 11: 110 mm standoff adapter provides precise offset positioning from the machine casing.\u003c\/li\u003e\n\u003cli\u003eOption 214: 214 mm probe penetration length accommodates deep installation requirements in large-diameter shafts or thick casings.\u003c\/li\u003e\n\u003cli\u003eOption 00: Fittings kit with no active conduit fittings, supplied with two washers and two blanking plugs to protect open ports.\u003c\/li\u003e\n\u003cli\u003eOption 02: 3\/4-14 NPT mounting thread ensures robust mechanical connection for the standoff adapter.\u003c\/li\u003e\n\u003cli\u003eGlass-reinforced polyphenylene sulfide (PPS) thermoplastic housing containing conductive fibers to withstand mechanical impact and dissipate electrostatic charge.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design combines both the probe and Proximitor sensor to eliminate extension cables and separate enclosures.\u003c\/li\u003e\n\u003cli\u003eType 4X and IP66 environmental ratings provide robust protection in harsh, wet, or corrosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHydroelectric, steam, and gas turbine shaft vibration and position monitoring.\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps, compressors, and fans in petrochemical and oil and gas installations.\u003c\/li\u003e\n\u003cli\u003eMachinery protection systems requiring simplified wiring setups without auxiliary junction boxes.\u003c\/li\u003e\n\u003cli\u003eWet or corrosive industrial applications requiring Type 4X and IP66 environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330881-28-11-214-00-02\u003c\/td\u003e\n\u003ctd\u003eMetric PROXPAC XL Proximity Transducer Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA: Probe and Approvals Option\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB: Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e110 mm standoff adapter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC: Probe Penetration Option (C Dimension)\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003ctd\u003e214 mm probe penetration length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD: Fittings Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE: Mounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (Required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330881-28-11-214-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Type\u003c\/td\u003e\n\u003ctd\u003eMetric PROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, 1-meter cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e7.59 +\/- 0.50 ohms (center to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Compatibility\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG), 3-conductor shielded triax recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between Proximitor sensor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), from approximately 0.25 mm (10 mils) to 2.3 mm (90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% (0 degC to +45 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) at 0 degC to +45 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (+0, -3 dB) with up to 305 meters of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers (UV resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated, 1-meter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Material\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (exposing below -34 degC may affect pressure seal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Housing\/Sensor)\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible (when properly sealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n\u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n\u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrounding: Ensure the internal grounding liner and retaining plate are properly connected to prevent ground loop interference.\u003c\/li\u003e\n\u003cli\u003eMoisture Prevention: Use proper conduit seals and routing loops to prevent moisture from traveling through the conduit and accumulating in the PPS housing.\u003c\/li\u003e\n\u003cli\u003eProbe Gap: Use the recommended gap setting of 1.27 mm (50 mils) corresponding to approximately -9 Vdc terminal output when configuring the system.\u003c\/li\u003e\n\u003cli\u003eStandoff Stiffening: Assemblies with a combined standoff adapter and probe penetration length (B + C dimensions) exceeding 305 mm require additional sleeve support near the probe tip to prevent mechanical resonance.\u003c\/li\u003e\n\u003cli\u003eTorque Limits: Tighten the probe sleeve locknut to 39.3 N-m (350 in-lb) and the outer housing retaining nut to 29.5 N-m (260 in-lb). Do not over-torque to prevent thread damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga, Ex ia IIIC T90C...T280C Dc (for hazardous dust atmospheres), Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003cli\u003eCSA\/North America: Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Zone 2: AEx\/Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003cli\u003eCE Mark: Complies with applicable European Union directives.\u003c\/li\u003e\n\u003cli\u003eIngress Protection: IP66 housing rating (verified by BASEEFA report T07\/0709) and Type 4X environment rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666760135019,"sku":"330881-28-11-214-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-11-214-00-02-proxpac-xl-proximity-transducer-qs1cgjiicyo_449dfe2c-7fd1-4ba4-8bcc-5438e13a45e9.jpg?v=1765447121","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330881-28-11-214-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}