{"product_id":"bently-nevada-330901-00-15-05-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-15-05-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eUnarmored 1\/4-28 UNF threaded probe body (Option 00) with 1.5 in overall case (Option 15) and 0.5 m lead length (Option 05) — \u003cstrong\u003e330901-00-15-05-02-05\u003c\/strong\u003e. This eddy-current non-contacting transducer is a part of the \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e system, used in confined spaces with tight clearances, small-bore machinery, and aeroderivative turbines where standard 5 mm or 8 mm systems do not fit because of sideview, counterbore, or rearview constraints.\u003c\/p\u003e\n\u003cp\u003eUnlike the armored 330902 variants, this configuration features a lightweight unarmored 1\/4-28 UNF threaded case. Its ClickLoc miniature coaxial connector connects directly to a 330930 extension cable and a 330980 Proximitor sensor. Option 02 specifies standard cabling without an integrated connector protector, and Option 05 grants multiple international hazardous area certifications (CSA, ATEX, IECEx) for installations in explosive atmospheres.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnarmored 1\/4-28 UNF threaded case configuration for direct standard-mount installations\u003c\/li\u003e\n\u003cli\u003eClickLoc miniature coaxial connector provides a stable electrical connection\u003c\/li\u003e\n\u003cli\u003e0.5 meter total probe length calibrated for compact routing\u003c\/li\u003e\n\u003cli\u003eFully threaded 1.5-inch case with 0.0-inch unthreaded length for maximum mounting flexibility\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) probe tip and AISI 304 stainless steel case resist corrosive industrial fluids\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals (Option 05) supporting global safety compliances\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and axial position measurements on high-speed shafts smaller than 51 mm\u003c\/li\u003e\n\u003cli\u003eTachometer, zero-speed, and Keyphasor phase reference signal acquisition\u003c\/li\u003e\n\u003cli\u003eCentrifugal, refrigeration, and process gas air compressor vibration monitoring\u003c\/li\u003e\n\u003cli\u003eAeroderivative gas turbine installations with severe physical clearance restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330901-00-15-05-02-05\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, standard mount, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in (38 mm) case length (ordered in increments of 0.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (20 in) total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Connector and Cable Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330901-00-15-05-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer System Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Armor\u003c\/td\u003e\n\u003ctd\u003eNone (unarmored cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 meters (19.7 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Sealing\u003c\/td\u003e\n\u003ctd\u003eViton O-ring pressure seal (sustained temperatures below -34 degC can affect seal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Torque\u003c\/td\u003e\n\u003ctd\u003e7.3 Nm (65 in-lb); Recommended torque: 5.1 Nm (45 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Strength\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) max rating (probe case to lead)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMaintain correct thread engagement. For 1\/4-28 UNF threads, the maximum length of thread engagement should not exceed 0.375 inches to avoid binding during installation. Ensure the minimum bend radius of 25.4 mm (1.0 in) is respected during cable routing. Secure the ClickLoc connection by hand-tightening, then applying the specified finger-tight torque. Exposing the probe to temperatures below -34 degC for sustained periods may degrade the Viton O-ring seal; verify your operating environment matches this limit.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx: Intrinsically Safe (ia) Ex ia IIC T5...T1 Ga; Non-sparking\/Increased Safety (nA, ec) Ex nA\/ec IIC T5...T1 Gc\u003c\/li\u003e\n\u003cli\u003eCNRTLUs: Class I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eFunctional Safety: SIL 2 capable (HFT=0), SIL 3 capable (HFT=1)\u003c\/li\u003e\n\u003cli\u003eRoHS: Compliant with European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eEMC: European Directive 2014\/30\/EU, EN 61000-6-2 and EN 61000-6-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666644955499,"sku":"330901-00-15-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-15-05-02-05-3300-nsv-proximity-probes-fqys0fw0xbp_e31c6a93-1138-413e-b891-a3fe224753f4.jpg?v=1765444601","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330901-00-15-05-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}