{"product_id":"bently-nevada-330908-00-18-10-02-05-3300-nsv-proximity-probes","title":"Bently Nevada 330908-00-18-10-02-05 3300 NSv Proximity Probes","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length) and Option 18 (1.8 in case length) specify this 3300 NSv proximity probe configuration — \u003cstrong\u003e330908-00-18-10-02-05\u003c\/strong\u003e. This configuration features a 1.0 m total cable length (Option 10) terminating in a miniature coaxial ClickLoc connector without a connector protector (Option 02), backed by multiple international hazardous area approvals (Option 05).\u003c\/p\u003e\n\u003cp\u003eUnlike armored options like the 330909 series or variants with integrated connector protectors (Option 01), the \u003cstrong\u003e330908-00-18-10-02-05\u003c\/strong\u003e utilizes an unarmored standard FEP-insulated coaxial cable, making it suitable for compact installations where conduit or external routing provides physical protection. Its 3\/8-24 UNF threaded case is ideal for tight-clearance applications where a larger 8 mm probe tip cannot be accommodated, yet a standard threaded mount is required. It integrates directly into a complete 3300 XL NSv transducer system, pairing with the 330930 extension cable and the 330980 Proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a fully threaded probe body with 0.0 in of unthreaded length.\u003c\/li\u003e\n  \u003cli\u003eOption 18 provides an overall case length of 1.8 in with standard 3\/8-24 UNF-2A threading.\u003c\/li\u003e\n  \u003cli\u003eOption 10 delivers a 1.0 m (39 in) FEP-insulated coaxial cable.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a gold-plated miniature coaxial ClickLoc connector for secure probe-to-cable termination without a pre-installed connector protector.\u003c\/li\u003e\n  \u003cli\u003eOption 05 includes multiple hazardous area agency approvals, including ATEX, IECEx, and CSA certificates.\u003c\/li\u003e\n  \u003cli\u003eTipLoc molding process creates a strong chemical and physical bond between the polyphenylene sulfide (PPS) probe tip and the AISI 304 stainless steel case.\u003c\/li\u003e\n  \u003cli\u003eCableLoc design offers up to 220 N (50 lb) of pull strength to prevent cable detachment from the probe body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial position and radial vibration measurements in small-bore machinery.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors and high-speed pumps with restricted target area geometries.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and auxiliary turbo-machinery with tight clearances.\u003c\/li\u003e\n  \u003cli\u003eFluid-film bearing monitoring on small shafts under 50 mm (2.0 in) where traditional 8 mm probes suffer from side-view sensitivity or cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18\u003c\/td\u003e\n      \u003ctd\u003e1.8 in (46 mm) case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet \/ 39 inches) probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (no connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, NEPSI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908-00-18-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Transducer System (pairs with 330930 extension cable and 330980 Proximitor sensor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (39 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.8 in (46 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.26 mm (0.207 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass miniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), typically from 0.25 mm to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) average scale factor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring, designed to seal differential pressure between tip and case (exposing to temperatures below -34 degC \/ -30 degF may degrade pressure seal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead, and probe lead to extension cable connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Recommended Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11.3 N m (100 in-lb) for 3\/8-24 case; maximum rated torque is 33.9 N m (300 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure proper operation and prolong system life, observe these installation guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Torque:\u003c\/strong\u003e Tighten the 3\/8-24 UNF probe case to a recommended installation torque of 11.3 N m (100 in-lb) to prevent thread or casing damage. Do not exceed the maximum rated torque of 33.9 N m (300 in-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) along the unarmored coaxial cable during routing to avoid signal attenuation or physical damage to the conductors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Clearance:\u003c\/strong\u003e Ensure the target shaft or surface meets the minimum flat target diameter of 8.9 mm (0.35 in). A target diameter of 13 mm (0.5 in) or larger is recommended to avoid shifts in scale factor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-talk Prevention:\u003c\/strong\u003e Maintain a center-to-center probe separation of at least 25 mm (1.0 in) for parallel axial probes, or 23 mm (0.9 in) for radial vibration configurations to eliminate electromagnetic cross-talk.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Maintenance:\u003c\/strong\u003e Prior to mating, ensure the ClickLoc connectors are free of oil, moisture, and debris. Use silicone self-fusing tape to protect connections in humid or wet environments (not recommended inside machine casings exposed to turbine oil).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean CE Mark:\u003c\/strong\u003e Complies with EMC Directive 2014\/30\/EU (Standards EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Directive 2011\/65\/EU and China RoHS regulations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e Approved under ABS and other maritime classification society standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0) or SIL 3 (HFT = 1) when integrated into an appropriately designed safety loop\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e Ex ia IIC T5...T1 Ga, Ex ia IIIC T90degC...T280degC Dc, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc, Class I Div 1 Groups A, B, C, D; Class II Groups E, F, G; Class III (intrinsically safe and non-incendive installations).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666556481899,"sku":"330908-00-18-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330908-00-18-10-02-05-3300-xl-25-mm-proximitor-sensor-hxzw2trapzi_f9f2f11e-987a-4ad7-ac59-5003380ca676.jpg?v=1765440619","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330908-00-18-10-02-05-3300-nsv-proximity-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}