{"product_id":"bently-nevada-3500-15-01-00-00-3500-series-power-supply-module","title":"Bently Nevada 3500\/15-01-00-00 3500 Series Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding reliable power conversion and conditioning for the 3500 Machinery Protection System, the \u003cstrong\u003eBently Nevada 3500\/15-01-00-00\u003c\/strong\u003e is a half-height power supply module designed for high-availability industrial monitoring environments. This specific configuration is engineered to accept \u003cstrong\u003elow-voltage AC input\u003c\/strong\u003e, converting mains power into the regulated DC voltages required by the backplane and installed monitoring cards. Designed for deployment in critical rotating machinery applications, it ensures continuous operation and signal integrity for critical protective racks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Voltage AC Capability:\u003c\/strong\u003e Specifically designed for utility supplies within the 85 to 132 Vac rms range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e Half-height physical design allows for efficient slot usage within the standard 3500 rack frame.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Isolation:\u003c\/strong\u003e Features high electromagnetic immunity to protect downstream rack components from line surges and transients.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Configuration:\u003c\/strong\u003e Configured as a single (non-redundant) supply option, ideal for non-critical or standardized plant architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eVibration monitoring systems in oil and gas refineries and petrochemical processing units.\u003c\/li\u003e\n  \u003cli\u003ePower generation facilities running steam or gas turbine monitoring assemblies.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater plants utilizing centralized rotating machinery protection systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500 Series Machinery Protection System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Supply Type (01)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLow Voltage AC (85 to 132 Vac rms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFrequency Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e47 to 63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSecondary Supply Option (00)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNo supply (for single-supply configuration setups)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAgency Approvals (00)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e25.0 cm x 15.0 cm x 10.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe legacy Bently Nevada 3500\/15-01-00-00 low-voltage AC module has been officially succeeded by the upgraded \u003cstrong\u003e3500\/15-05-00-00\u003c\/strong\u003e power supply. The newer model features optimized internal regulation circuitry designed for higher thermal efficiency. When upgrading or replacing older units, ensure that any companion redundant power supplies share the identical input voltage classification to avoid potential backplane loading issues.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis unit is configured for \u003cstrong\u003esingle-supply operation\u003c\/strong\u003e (-00 secondary option). In critical protection architectures where rack downtime is unacceptable, dual-redundant configurations should be specified instead. Operating a single-supply rack exposes the system to complete monitoring loss if the incoming utility line experiences a power dip or localized component failure. Always ensure there is sufficient ventilation space above and below the 3500 rack to dissipate heat, as over-temperature conditions can prematurely degrade the module's internal filtering capacitors.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eIncoming power lines must be routed through a dedicated, external double-pole circuit breaker located near the rack for safe maintenance isolation. Use high-quality shielded cables for AC input power to prevent electromagnetic interference from coupling into adjacent low-voltage sensor cables. The chassis ground stud on the 3500 rack backplane must be connected directly to a low-impedance instrument earth ground system to ensure stable operation and correct surge protection performance.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDisconnect all primary AC electrical sources and lock out\/tag out raw power links before removing, inserting, or wiring this module. Hazardous voltages are present on the terminal block and backplane during system operation. Failure to completely de-energize the unit can result in severe personal injury or equipment destruction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the main feed circuit breaker for the 3500 rack is completely switched off and tagged out.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the 3500\/15-01-00-00 module carefully into the designated slot on the left-hand side of the 3500 rack until it fully seats into the backplane connectors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTighten the chassis retaining screws securely to ground the front panel and prevent mechanical vibrations from backing the module out of place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTerminate the AC power supply wiring to the input terminals, double-checking all polarities and earth ground connections prior to energization.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302721387,"sku":"3500\/15-01-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-01-00-00-psg3244fce0_fba6248e-9d2e-44d2-beb3-f7358ce374e7.jpg?v=1765520592","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3500-15-01-00-00-3500-series-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}