{"product_id":"bently-nevada-3500-15-03-03-00-3500-series-power-supply-module","title":"Bently Nevada 3500\/15-03-03-00 3500 Series Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered to deliver backplane power for the 3500 Machinery Protection System, the Bently Nevada 3500\/15-03-03-00 is a half-height module designed for high-availability industrial monitoring environments. This specific configuration operates with high-voltage DC inputs across both the top and bottom slots, establishing a robust power foundation. By providing consistent regulated voltages to all modules in the rack, it maintains system integrity and ensures uninterrupted monitoring of critical rotating assets.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDual-redundancy support when two modules are installed in a redundant backplane.\u003c\/li\u003e\n  \u003cli\u003eDedicated high-voltage DC input capabilities for both slot positions.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in electromagnetic interference (EMI) filtering to prevent electrical noise propagation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated overvoltage, overcurrent, and short-circuit protection circuits.\u003c\/li\u003e\n  \u003cli\u003eFront panel LED indicators for immediate monitoring of power supply health status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSteam and gas turbine protection systems.\u003c\/li\u003e\n  \u003cli\u003eLarge industrial compressor and pump monitoring setups.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric and thermal power generation facilities.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical plants and oil refinery rotating machinery assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/15-03-03-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500 Machinery Protection System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Supply Type (Top Slot)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eHigh Voltage DC (88 to 140 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Supply Type (Bottom Slot)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eHigh Voltage DC (88 to 140 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNone (00 Option)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e88 to 140 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eForm Factor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eHalf-height slot module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.39 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The 3500\/15 power supply module must be installed in a 3500 series chassis containing a compatible power supply backplane. If migrating from older legacy single-supply systems to a redundant power layout, ensure the physical backplane is upgraded to the redundant version. High-voltage DC modules are functionally interchangeable with other voltage configurations (such as low-voltage DC or high-voltage AC) provided the underlying backplane and source wiring align with the correct voltage ratings.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When sizing the upstream DC source feeding the 88 to 140 Vdc inputs, verify that transient current capability is sufficient to handle initial rack power-up rushes or transient loads during module hot-swapping. Operating this power supply in high-temperature, unventilated enclosures (exceeding 50 degC) will reduce the service life of internal filtering capacitors. Maintain a clear airflow path around the rack chassis to prevent thermal hotspots.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  For true physical redundancy, route the input power feeds for the top and bottom slots from independent electrical sources (e.g., separate DC distribution panels). Always employ dedicated external circuit breakers to isolate individual faults. Ground the chassis directly to the plant's low-impedance safety ground bus using minimum 2.5 mm2 (14 AWG) copper wire to mitigate high-frequency electrical noise that could degrade adjacent proximity probe measurements.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003e\n    Disconnect and lock out all upstream electrical power sources before attempting to install, remove, or wire this module. High-voltage DC sources (88 to 140 Vdc) pose severe electrical shock hazards. Verify the complete absence of voltage with a calibrated instrument before contacting any terminals.\n  \u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the 3500\/15 power supply module firmly into the dedicated power slot on the left side of the 3500 rack chassis until it seats completely into the backplane connectors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTighten the front panel thumbscrews securely using a flat-head screwdriver to ensure stable mechanical grounding and prevent vibration-induced loosening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the DC power lines to the corresponding terminals on the rear backplane terminal block, applying the recommended torque specifications and verifying polarity.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302295403,"sku":"3500\/15-03-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-03-03-00-53l1cltjmof_a990bd21-54d5-49a1-a37f-3cb4d597e70b.jpg?v=1765520578","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3500-15-03-03-00-3500-series-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}