{"product_id":"bently-nevada-3500-22-01-01-01-288055-01-146031-01-transient-data-interface","title":"Interface de Dados Transitórios Bently Nevada 3500\/22-01-01-01 | 288055-01 +146031-01","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003e3500\/22M\u003c\/strong\u003e Interface de Dados Transitórios (TDI), especificamente solicitado sob o número de peça de configuração \u003cstrong\u003e3500\/22-01-01-01\u003c\/strong\u003e (composto pelo módulo principal \u003cstrong\u003e288055-01\u003c\/strong\u003e e módulo de E\/S \u003cstrong\u003e146031-01\u003c\/strong\u003e), fornece uma interface dedicada entre o sistema de monitoramento 3500 e softwares compatíveis de configuração ou monitoramento de condição. Este módulo combina as funções básicas de interface de rack de um Módulo de Interface de Rack 3500\/20 (RIM) padrão com as capacidades de coleta de dados de alta capacidade de um processador de comunicação avançado. Ele se conecta diretamente com os monitores da série M dentro do rack para coletar continuamente dados de formas de onda dinâmicas em estado estacionário e transitório, transferindo essas informações via link Ethernet para plataformas de software host. Enquanto o \u003cstrong\u003e3500\/22M\u003c\/strong\u003e fornece processamento vital de dados do sistema, operando fora do caminho crítico de monitoramento, garantindo que as funções de proteção da máquina permaneçam totalmente disponíveis e completamente inalteradas pelas operações do módulo.\u003c\/p\u003e\n\u003ch3\u003eCaracterísticas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegra as funções de um Módulo de Interface de Rack padrão e um processador de comunicação em um único slot.\u003c\/li\u003e\n\u003cli\u003eSuporta coleta contínua tanto de valores em estado estacionário quanto de formas de onda dinâmicas transitórias de alta resolução.\u003c\/li\u003e\n\u003cli\u003eInclui captura padrão de dados estáticos com habilitação opcional de canal dinâmico via disco de validação especializado.\u003c\/li\u003e\n\u003cli\u003eFornece caminhos de comunicação duplos via USB no painel frontal e configurações Ethernet no painel traseiro.\u003c\/li\u003e\n\u003cli\u003eOpera como um componente não interferente em relação aos caminhos de segurança e proteção automática do rack de monitoramento.\u003c\/li\u003e\n\u003cli\u003eApresenta quatro valores estáticos nX configuráveis por ponto de canal, completos com rastreamento de amplitude e fase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoramento de vibração de máquinas e análises de manutenção preditiva.\u003c\/li\u003e\n\u003cli\u003eRegistro de dados de partida e desaceleração de turbomáquinas.\u003c\/li\u003e\n\u003cli\u003eCaptura contínua de eventos transitórios e formas de onda na geração industrial de energia.\u003c\/li\u003e\n\u003cli\u003eGerenciamento de configuração e diagnóstico remoto para racks industriais de motores e bombas em grande escala.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformações para Pedido\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCódigo do Componente \/ Sufixo\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrição\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/22-01-01-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNúmero de Pedido do Conjunto Completo do Módulo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTipo de Interface de Dados Transitórios: Padrão (uso para aplicações padrão de monitoramento)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTipo de Módulo I\/O: Módulo I\/O Ethernet 10Base-T\/100Base-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAprovação de Agência: CSA\/NRTL\/C (Classe 1, Divisão 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e288055-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMódulo de Interface de Dados Transitórios padrão com cabo USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMódulo I\/O 10Base-T\/100Base-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e123M4610\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabo USB de 1 pé A para B (Incluído com 288055-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategoria do Parâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePaís de Origem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEUA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,5 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConexão Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ-45 para 10Base-T\/100Base-TX, detecção automática, 100 metros máximo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface USB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta USB-B no painel frontal, 115,2 kbaud máximo, cabo com comprimento máximo de 5 metros\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelé OK Padrão\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClassificado até 5A @ 24 Vcc \/ 120 Vca, 120 Watts \/ 600 VA potência máxima comutada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasors Suportados\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 sinais Keyphasor do sistema até 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFaixas de Velocidade Keyphasor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 a 16 canais: 1 a 100.000 rpm; 17 a 24 canais: 1 a 60.000 rpm; 25 a 48 canais: 1 a 30.000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCanais de Forma de Onda\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eColeta simultânea para 48 canais, acoplados em DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso do Módulo Principal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,91 kg (2,0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões do Módulo Principal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 pol x 0,96 pol x 9,52 pol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso do Módulo I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,20 kg (0,44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões do Módulo I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 pol x 0,96 pol x 3,90 pol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso Total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOcupação do Slot do Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot frontal de altura total (Módulo Principal), 1 slot traseiro de altura total (Módulo I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 °C a +65 °C (-22 °F a +149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura de Armazenamento\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C (-40 °F a +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidade Relativa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% sem condensação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVida Útil da Bateria (Com Energia)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 anos a 50 °C (122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVida Útil da Bateria (Sem Energia)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 anos a 50 °C (122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface do Sistema\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção \/ Descrição\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta USB-B Frontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConexão direta ao computador utilizando Protocolo BN Host para configuração local e extração de dados.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta RJ-45 (I\/O de Cobre)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterface principal para conexões de rede usando Ethernet TCP\/IP suportando protocolos BN Host e TDI.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConector de Terra de 2 Pinos\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBloco terminal específico no módulo I\/O para conectar Sinal Comum ao Terra do Instrumento.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal de Contatos do Sistema\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePinos dedicados para entradas cabeadas para Trip Multiply, Inibição de Alarme e Reset do Rack.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequisitos de Slot:\u003c\/strong\u003e O módulo principal deve sempre ser instalado no Slot 1, diretamente adjacente aos conjuntos de fonte de alimentação do rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecaução na Atualização:\u003c\/strong\u003e Ao substituir um RIM 3500\/20 antigo, você deve extrair completamente tanto o módulo RIM antigo quanto o cartão I\/O RIM antigo antes de inserir qualquer hardware novo. Não remover o cartão I\/O RIM legado antes de instalar o novo módulo causará danos graves ao hardware do TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequência de Atualização:\u003c\/strong\u003e Siga esta ordem exatamente: 1) Remova o RIM existente, 2) Remova o cartão I\/O do RIM existente, 3) Instale o novo cartão I\/O TDI, 4) Instale o novo módulo principal TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguração de Aterramento:\u003c\/strong\u003e Ao usar o conector comum de sinal de 2 pinos para ligar ao terra do instrumento, deslize o interruptor seletor localizado no Módulo de Entrada de Energia (PIM) em direção à marca \"HP\" para isolar corretamente o comum de sinal do terra do chassi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConectividade USB:\u003c\/strong\u003e Sempre utilize o cabo USB dedicado (Número da Peça 123M4610) para preservar o isolamento elétrico entre o chassi e o terra. Além disso, certifique-se de que o computador conectado esteja operando exclusivamente com sua bateria interna (completamente desconectado da rede\/terra) para evitar a geração de loops de terra perigosos.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformidade e Certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Conforme a Parte 15 das Regras FCC para interferência.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiretivas EMC:\u003c\/strong\u003e Diretiva da Comunidade Europeia 2014\/30\/EU; Normas EN 61000-6-2 (Imunidade) e EN 61000-6-4 (Emissões).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegurança Elétrica:\u003c\/strong\u003e Diretiva da Comunidade Europeia 2014\/35\/EU; Norma EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Diretiva da Comunidade Europeia 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormas Marítimas:\u003c\/strong\u003e Regras DNV GL para classificação (Navios, unidades offshore); Regras ABS para Condição de Classificação Parte 1, Regras para Embarcações de Aço, Unidades e Estruturas Offshore.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAprovações para Áreas Perigosas:\u003c\/strong\u003e Classe I, Divisão 2, Grupos A, B, C e D (cNRTLus) certificadas para faixa de temperatura específica de -20 °C a +65 °C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321661291,"sku":"288055-01 +146031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022-01-01-01288055-01-146031-01-nwwli4ezpyt_52447ece-9c82-498c-b49d-ca113d00625d.jpg?v=1765521166","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3500-22-01-01-01-288055-01-146031-01-transient-data-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}