{"product_id":"bently-nevada-3500-22-01-02-cn-3500-series-transient-data-interface","title":"Bently Nevada 3500\/22-01-02-CN 3500 Series Transient Data Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating continuous machinery protection with diagnostic data acquisition, the Bently Nevada 3500\/22-01-02-CN serves as the primary communication interface between 3500 Series racks and System 1 software. This Transient Data Interface (TDI) acts as a highly specialized bridge, processing static and dynamic configuration parameters and collecting transient waveform data across all slotted monitor modules. Configured with a \u003cstrong\u003e100Base-FX Fiber Optic\u003c\/strong\u003e interface, this module is built for long-distance, high-noise industrial communication loops where standard copper-based Ethernet is susceptible to electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransient Data Capture:\u003c\/strong\u003e Automatically collects waveform data during startup, coast-down, and alarm-triggered events for advanced machinery diagnostics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100Base-FX Fiber Optic I\/O:\u003c\/strong\u003e Ensures robust, noise-immune high-speed Ethernet communications across long industrial distances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Monitoring Support:\u003c\/strong\u003e Programmed for standard turbine and rotating machinery monitoring architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem 1 Integration:\u003c\/strong\u003e Direct, high-bandwidth telemetry output compatible with Bently Nevada software suites for predictive maintenance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCN Certification:\u003c\/strong\u003e Verified with country-specific compliance standards for direct deployment in restricted industrial zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSteam and gas turbine supervisory instrumentation (TSI) setups.\u003c\/li\u003e\n  \u003cli\u003eHigh-voltage electrical substation machinery integration with severe EMI profiles.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and offshore oil platform machinery monitoring networks.\u003c\/li\u003e\n  \u003cli\u003eLarge-scale compressor train and cooling tower fan vibration telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eProduct Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003e3500\/22-01-02-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eTDI Module Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003eStandard Transient Data Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eI\/O Module Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003e100Base-FX (Fiber Optic) Ethernet I\/O\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eAgency Approval Option\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003eCN (Country Specific Approvals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003e24.13 cm x 2.44 cm x 24.18 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003e2.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 12px; text-align: left; font-weight: bold;\"\u003eInterface Connection\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 12px; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eTX\/RX Fiber Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003e100Base-FX multi-mode fiber connection for primary control room communications.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px; font-weight: bold;\"\u003eFront Panel Port\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 12px;\"\u003eSerial\/USB-compatible service port for local laptop engineering connection.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 3500\/22M TDI directly replaces older legacy 3500\/20 Rack Interface Modules (RIM). However, upgrading from a 3500\/20 to a 3500\/22 requires updating the 3500 Rack Configuration Software and ensuring that the firmware matches your running version of System 1 diagnostic software.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing the 100Base-FX fiber optic I\/O option, always adhere strictly to the minimum bend radius specifications of the multi-mode fiber cabling. Tight bends inside high-density enclosure channels can lead to packet drop errors, which disrupts System 1 live waveform rendering and delays transient event capture.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure that fiber optic connector tips are thoroughly inspected with an optical scope and cleaned with lint-free wipes prior to insertion. Even microscopic dust particles on the 100Base-FX ports can significantly degrade light transmission levels, triggering communication timeout alarms.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDo not hot-swap the 3500\/22M TDI module while the machinery is active and relying on relay outputs or safety interlocking logic. Inserting or removing the TDI can momentarily interrupt rack communication loops and cause state faults. Ensure all bypass interlocks are active if servicing a live system.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the main 3500\/22M TDI module into the designated slot of the 3500 rack (typically the slot adjacent to the power supplies).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign and secure the 100Base-FX Fiber Optic I\/O module into the corresponding rear slot position, hand-tightening the retaining screws.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the fiber cables to the TX\/RX ports and verify that the front panel Link LED illuminates, indicating valid hardware negotiation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668297576811,"sku":"3500\/22-01-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-22-01-02-CN-3znaqsbffdd_5e6d60b0-2caf-48d9-8cce-f335281390c2.jpg?v=1765520447","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3500-22-01-02-cn-3500-series-transient-data-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}