{"product_id":"bently-nevada-3500-62-03-00-137110-01-process-variable-monitor","title":"Monitor de Variável de Processo Bently Nevada 3500\/62-03-00 137110-01","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/62-03-00 (137110-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um Monitor de Variáveis de Processo de alta confiabilidade com 6 canais, projetado para o Sistema de Proteção de Máquinas Bently Nevada 3500. Este módulo é especificamente desenvolvido para processar parâmetros críticos da máquina que requerem vigilância contínua, como pressão, fluxo, temperatura e níveis de tanque. A variante\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/62-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé configurada com um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMódulo I\/O Isolado de 4 a 20 mA\u003c\/strong\u003e, garantindo a integridade do sinal em ambientes eletricamente ruidosos comuns em refinarias de petróleo, plantas químicas e usinas de energia. Ao comparar sinais de entrada condicionados com pontos de alarme programáveis pelo usuário, o monitor fornece proteção instantânea da máquina e dados essenciais para as operações da planta. Sua implantação é vital para reduzir paradas não programadas, identificando desvios de processo antes que causem falhas nos ativos mecânicos.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eA arquitetura\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/62\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetada para máxima flexibilidade e monitoramento de alta disponibilidade dentro de um rack 3500.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessamento de Seis Canais:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCondiciona e monitora independentemente até seis entradas de processo separadas, proporcionando alta densidade de proteção em um único slot do rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface I\/O Isolada:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA opção\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epossui um módulo I\/O isolado de 4-20 mA com terminações internas, oferecendo 500 Vdc de isolamento para proteger a eletrônica do rack contra surtos elétricos do lado do campo e loops de terra.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibilidade TMR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuando usado em configuração Triple Modular Redundant (TMR), os monitores são instalados em grupos de três com módulos I\/O adjacentes para garantir proteção sem perda mesmo no caso de falha de um único módulo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramabilidade via Software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTotalmente configurável pelo Software de Configuração do Rack 3500, permitindo que os operadores definam fatores de escala personalizados, lógica de supressão de alarmes e unidades de sinal (ex.: psi, bar, Celsius, litros\/min).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/62-03-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolado +4 a +20 mA com Terminações Internas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eQuantidade de Canais\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Canais\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,0 Watts típico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedância de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kOhm (Tensão) \/ 250 Ohm (Corrente)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolução\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,3662 microamperes por bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrecisão\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0,33 por cento da escala total típico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 a +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensões (Monitor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 241,8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso (Monitor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Aplicações Industriais\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual a diferença entre o 3500\/62 e os monitores de vibração padrão?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnquanto os monitores de vibração focam em sinais dinâmicos de alta frequência (corrente parasita\/sísmicos), o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/62\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetado para variáveis de processo \"estáticas\". Ele aceita sinais de 4-20 mA ou +\/- 10 Vdc, permitindo que o rack 3500 atue como um sistema unificado de proteção tanto para vibração mecânica quanto para segurança de processo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEste módulo pode ser usado em aplicações Intrinsecamente Seguras (I.S.)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/62-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutiliza um módulo I\/O isolado, mas não inclui barreiras Zener internas. Para instalações em áreas perigosas que exigem proteção I.S., deve-se selecionar a variante\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMódulo I\/O com Barreira Interna\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(como o 136499-01), que inclui fusíveis de 250 mA integrados e circuitos de barreira.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO que indica uma falha no loop 4-20 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLED OK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eno painel frontal apagará ou piscará se o monitor detectar falha no transdutor ou sinal de corrente \"fora de faixa\" (tipicamente \u0026lt; 3,6 mA ou \u0026gt; 21 mA). Isso garante que um fio de campo rompido nunca seja confundido com uma leitura válida do processo.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia de Campo e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminação e Cabeamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara o I\/O Isolado\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e137110-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, certifique-se de que os fios de campo 4-20 mA estejam conectados firmemente aos blocos de terminais internos. Use cabo blindado de par trançado para todas as entradas e termine a blindagem apenas no terra do sistema 3500 para evitar loops de terra que possam corromper a medição.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformidade Isolada:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO I\/O isolado fornece 500 Vdc de isolamento canal a canal e canal a rack. Isso é crítico ao conectar múltiplas fontes de energia externas diferentes, pois previne vazamento de corrente entre loops que poderia causar erros de offset no DCS ou PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguração da Lógica de Alarme:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAo configurar via software 3500, assegure que os pontos de ajuste \"Alerta\" e \"Perigo\" estejam dentro da faixa linear do transdutor. Para sistemas TMR, verifique se a lógica de votação (ex.: 2 de 3) está corretamente atribuída no Módulo de Interface do Rack (RIM) para evitar disparos indevidos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento Térmico:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSe operar próximo ao limite superior de 65 °C, garanta que o rack tenha refrigeração suficiente. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/62\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egera aproximadamente 7 watts de calor; em um rack totalmente carregado, recomenda-se refrigeração forçada para manter a precisão de medição especificada de +\/- 0,33%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855063915,"sku":"3500\/62-03-00 137110-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-62-03-00-137110-01-i-o-module-with-internal-terminations-b2vsimphega_d53dd6a8-11a5-4fea-8af1-3968f76df941.jpg?v=1765449159","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3500-62-03-00-137110-01-process-variable-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}