{"product_id":"bently-nevada-3500-65-01-cn-3500-65-16-channel-temperature-monitor","title":"Bently Nevada 3500\/65-01-CN 3500\/65 16-Channel Temperature Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/65-01-CN\u003c\/strong\u003e provides 16 channels of continuous temperature monitoring , accepting resistance temperature detector (RTD) and isolated tip thermocouple (TC) inputs. This temperature monitor conditions all field signals and evaluates them against user-programmable Alert and Danger alarm setpoints. Configured via the 3500 Rack Configuration Software, it handles isolated tip thermocouples, 3-wire RTDs, 4-wire RTDs, or combined TC\/RTD arrangements. In Triple Modular Redundant (TMR) setups, monitors operate in adjacent groups of three, utilizing dual voting methodologies to maintain high operational integrity and eliminate single-point failures. The \u003cstrong\u003e3500\/65-01-CN\u003c\/strong\u003e configuration specifically designates an I\/O module type featuring internal terminations along with country-specific agency approvals.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcesses up to 16 channels of RTD or isolated tip TC inputs per module.\u003c\/li\u003e\n\u003cli\u003eSupports multiple sensor configurations, including 3-wire and 4-wire platinum, nickel, and copper RTDs alongside diverse TC options.\u003c\/li\u003e\n\u003cli\u003eIntegrates software-programmable Alert and Danger alarm delays to optimize system event responses.\u003c\/li\u003e\n\u003cli\u003eEmploys Front Panel LEDs (OK, TX\/RX, Bypass) for rapid, direct verification of module, communication, and operational status.\u003c\/li\u003e\n\u003cli\u003eEnables Triple Modular Redundant (TMR) voting across adjacent hardware groups to enforce high fault tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and continuous thermal tracking on industrial rotating assets.\u003c\/li\u003e\n\u003cli\u003eBearing temperature supervision across large motors, pumps, and compressors.\u003c\/li\u003e\n\u003cli\u003eExhaust gas temperature monitoring on industrial gas turbines.\u003c\/li\u003e\n\u003cli\u003eWinding temperature analysis for high-voltage generators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/65\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Channel Temperature Monitor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD\/Isolated Tip TC with Internal Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprovals country specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMade in\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 watts nominal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 MOhm for each lead input \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e913 +\/- 7 uA @ 25 degC per transducer \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space - Main Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space - I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting\u003c\/strong\u003e: Install the main module into a full-height front chassis slot and place the corresponding internal termination I\/O module into the matching full-height rear chassis slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTMR Configuration\u003c\/strong\u003e: When arranging a Triple Modular Redundant layout, you must place three temperature monitors in adjacent rack slots to support correct voting routines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Verification\u003c\/strong\u003e: Ensure that the 3500\/22 transient data interface module firmware stands at Revision 1.50 or later, and matching configuration software is updated appropriately to support module additions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation\u003c\/strong\u003e: Do not attempt to hook up external termination blocks if an internal termination I\/O module architecture is used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards\u003c\/strong\u003e: European Community Directive 2014\/30\/EU, EN 61000-6-2 (Industrial Immunity), and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e: European Community Directive 2014\/35\/EU compliant via EN 61010-1 standard validation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\/China RoHS\u003c\/strong\u003e: Compliant with European Directive 2011\/65\/EU and marked with a 15-year Environment-Friendly Use Period (EFUP) under SJ\/T 11364-2024 for associated cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals\u003c\/strong\u003e: Verified under ABS rules for Marine and Offshore Applications along with DNV GL Rules for Classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e: North American Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC). Also meets ATEX\/IECEx certifications for Ex nA nC ic IIC T4 Gc and Ex ec nC ic IIC T4 Gc zones.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668311798123,"sku":"3500\/65-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350065-01-CN-gchr5tdlhag_1a9363ce-977c-47d6-baac-40f5874ee1b6.jpg?v=1765520872","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3500-65-01-cn-3500-65-16-channel-temperature-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}