{"product_id":"ge-fanuc-field-control-ic670chs003-terminal-block-connector-base-barrier-style","title":"Base Conector de Bloco Terminal (Estilo Barreira) GE Fanuc Field Control IC670CHS003","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-192\"\u003eO \u003c\/span\u003e\u003cstrong\u003eIC670CHS003 (IC670-CHS-003)\u003c\/strong\u003e\u003cspan class=\"citation-192\"\u003e é uma base de conector de bloco terminal de alta densidade, \u003c\/span\u003e\u003cstrong\u003eestilo barreira\u003c\/strong\u003e\u003cspan class=\"citation-192 citation-end-192\"\u003e projetada para o sistema GE Fanuc Field Control I\/O.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-191 citation-end-191\"\u003eEsta base atua como a plataforma física de montagem e interface elétrica para os módulos Field Control I\/O.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Diferente do estilo \"caixa\" (CHS002), o \u003cstrong\u003eestilo barreira\u003c\/strong\u003e CHS003 possui terminais de parafuso abertos com divisórias físicas, tornando-o ideal para aplicações que exigem bitolas de fio maiores ou terminações com olhais\/espátulas. Facilita a \"Fiação Permanente\", permitindo a substituição dos módulos I\/O sem desconectar os cabos do lado do campo, o que reduz significativamente o tempo de inatividade durante a manutenção em ambientes críticos como usinas, estações de tratamento de água e linhas de montagem automatizadas.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eO IC670CHS003 oferece \u003cstrong\u003e36 terminais\u003c\/strong\u003e dispostos em configuração de barreira. Ele é facilmente montado em um trilho DIN padrão de 35mm ou pode ser fixado diretamente em um subpainel. A base contém o barramento local interno que conecta o módulo I\/O à Unidade de Interface de Barramento (BIU). O design em barreira é especificamente projetado para evitar curtos-circuitos acidentais entre terminais adjacentes ao usar fiação pesada. Suporta módulos digitais e analógicos, desde que o pinout do módulo seja compatível com um esquema de terminação de 36 pontos.\u003c\/p\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModelo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC670CHS003\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarca\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSérie\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Control I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTipo de Base\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConector de Bloco Terminal (Estilo Barreira)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNúmero de Terminais\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTipo de Montagem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrilho DIN 35mm ou Montagem em Painel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBitola do Fio\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAté 12 AWG (dependendo do tipo de terminal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensão Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC \/ VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrente Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amperes por terminal (Máximo)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensões\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13,5 x 4,5 x 5,2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeso\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual a principal diferença entre o CHS003 e o CHS002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO \u003cstrong\u003eIC670CHS003\u003c\/strong\u003e é uma base de \u003cstrong\u003eestilo barreira\u003c\/strong\u003e (terminals abertos com divisórias), enquanto o CHS002 é uma base de \u003cstrong\u003eestilo caixa\u003c\/strong\u003e (fios inseridos em uma gaiola). O CHS003 é mais adequado para fios maiores e uso com terminais de crimpagem, enquanto o CHS002 é mais compacto para fiação de bitola fina.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso misturar diferentes tipos de módulos nesta base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmbora a base seja fisicamente compatível com a maioria dos módulos Field Control, cada base é dedicada a um módulo específico por vez. Você deve garantir que a chave mecânica na base corresponda ao módulo que pretende inserir para evitar danos ao hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEsta base é compatível com o mais recente Emerson\/PACSystems Field Control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. A linha Field Control foi originalmente da GE Fanuc e agora é suportada pela Emerson. O IC670CHS003 continua sendo a base padrão estilo barreira durante todo o ciclo de vida desta família de I\/O.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMétodo de Terminação:\u003c\/strong\u003e Use terminais de olhal ou espátula sempre que possível com a base barreira CHS003. Isso garante máximo contato de superfície e evita que fios se soltem, causando curto-circuito entre os terminais de alta densidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChaveamento Mecânico:\u003c\/strong\u003e Antes de encaixar o módulo I\/O na base, verifique os dois discos de chaveamento plásticos no CHS003. Eles devem estar ajustados para o código específico do seu módulo (ex.: Entrada de 16 pontos, Saída de Relé, etc.). Se as chaves não estiverem alinhadas, o módulo não encaixará corretamente—\u003cstrong\u003enão force.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção do Barramento:\u003c\/strong\u003e Quando a base estiver montada, mas sem módulo instalado, os conectores internos do barramento ficam expostos. Mantenha a tampa plástica protetora para evitar poeira, umidade ou detritos metálicos que possam contaminar os pinos banhados a ouro.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695409164651,"sku":"IC670CHS003","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic670chs003-terminal-block-ezwbsrhjbyh_72425880-867c-43d2-9655-1266d9931570.jpg?v=1766134996","url":"https:\/\/www.plcprotech.com\/pt\/products\/ge-fanuc-field-control-ic670chs003-terminal-block-connector-base-barrier-style","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}