{"product_id":"ge-fanuc-ic693bem341-series-90-30-fip-bus-controller","title":"Controlador de Barramento FIP Série 90-30 GE Fanuc IC693BEM341","description":"\u003ch3\u003eVisão Geral\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e é um Controlador de Barramento FIP (Factory Instrumentation Protocol) de alto desempenho, projetado para o ecossistema PLC GE Fanuc Série 90-30. Atuando como uma ponte crítica de comunicação, esta versão de 2,5 MHz facilita a troca determinística de dados em alta velocidade em ambientes industriais exigentes, como geração de energia, tratamento de água e manufatura em grande escala. Ao atualizar a velocidade da rede do padrão anterior de 1,0 MHz, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimiza a latência da rede e garante a sincronização em tempo real entre os conjuntos distribuídos de E\/S e dispositivos escravos. Sua integração é vital para reduzir o tempo de inatividade do sistema e manter a integridade dos dados em arquiteturas automatizadas complexas.\u003c\/p\u003e\n\u003ch3\u003eCapacidades Funcionais \u0026amp; Arquitetura\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintroduz a configuração Modo 30, uma evolução significativa em relação ao legado Modo 11. Este modo operacional transforma o controlador em um centro robusto de gerenciamento capaz de lidar com redundância e serviços complexos de mensagens.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuporte à Redundância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaior disponibilidade do sistema por meio de configurações redundantes do controlador, essencial para processos críticos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento de Escravos:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupervisão completa dos conjuntos de E\/S, acionamentos e estações de controle, permitindo monitoramento e diagnóstico centralizados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegistro de Tempo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegistro preciso de eventos para até 1024 valores booleanos, utilizando o formato POSIX COMV para rastreamento cronológico padronizado.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTroca Síncrona:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA implementação dos serviços MPS (Mensagem Periódica\/Esparsa) garante que os dados produzidos e consumidos permaneçam perfeitamente alinhados com o ciclo de varredura do PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrincipais Especificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC693BEM341\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSérie 90-30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocolo de Comunicação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFIP (WorldFIP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVelocidade do Barramento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,5 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibilidade de CPU\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCPU PLC IC693 Release 8.10 ou superior\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFerramentas de Configuração\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUtilitário FBCLOAD, HHP ou IC641CTLxxx Rel 2.0+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEUA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes de Engenharia\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo o IC693BEM341 difere do IC693BEM340?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA principal diferença é a velocidade de transmissão da rede. O BEM341 opera a 2,5 MHz, enquanto o BEM340 é limitado a 1,0 MHz. Embora sejam funcionalmente idênticos em termos de lógica, o BEM341 requer um firmware de CPU mais recente (Release 8.10 ou superior) para funcionar corretamente.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso usar o software padrão IC641SWPxxx para configurar este módulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. Esta versão do Controlador de Barramento FIP não é compatível com o software de programação IC641SWPxxx. Você deve usar o Programador Portátil (HHP), o IC641CTLxxx para Windows Release 2.0 ou posterior, ou o utilitário de configuração FBCLOAD.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a importância da nova funcionalidade Modo 30?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO Modo 30 é uma extensão do Modo 11 que adiciona recursos industriais críticos, incluindo redundância de hardware, gerenciamento de dispositivos escravos (conjuntos e acionamentos) e a capacidade de receber configurações externas diretamente pela rede FIP.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia \u0026amp; Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSincronização de Firmware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAntes de instalar o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e, verifique se sua CPU Série 90-30 está atualizada para pelo menos o Release 8.10. Não atender a este requisito mínimo de firmware resultará em erros de configuração ou falha \"Perda do Módulo\" no hardware\/software do PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminação da Rede:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEm 2,5 MHz, a integridade do sinal é altamente sensível a incompatibilidades de impedância. Certifique-se de que os terminadores padrão FIP estejam instalados corretamente em ambas as extremidades físicas do barramento para evitar reflexões de sinal e corrupção de dados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguração de Redundância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAo utilizar o Modo 30 para aplicações redundantes, assegure-se de que o carregador de configuração externo FBCLOAD seja da Versão 2.0 ou superior. Versões anteriores do carregador são incompatíveis com as atualizações específicas de registro de tempo e tipo de assinante exigidas pelas especificações modernas do Gerenciador de Dispositivos FIP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695413555563,"sku":"IC693BEM341","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic693bem341-fip-bus-controller-3e5roshshhw_9fb4745b-2105-4dc2-9333-5233c6194595.jpg?v=1766135153","url":"https:\/\/www.plcprotech.com\/pt\/products\/ge-fanuc-ic693bem341-series-90-30-fip-bus-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}