{"product_id":"ge-mark-v-ds200tccag1baa-tc2000-common-analog-i-o-board","title":"Placa Analógica Comum I\/O TC2000 GE Mark V DS200TCCAG1BAA","description":"\u003ch3\u003eVisão Técnica \u0026amp; Implantação Industrial\u003c\/h3\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCAG1BAA (DS200TCCAG1BAA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um instrumento de processamento analógico de sinais em nível central desenvolvido pela General Electric para o sistema legado de controle de turbinas a gás e vapor Mark V Speedtronic. Operando a partir do núcleo central de controle R5, esta placa de interface multicamadas atua como o nó principal de agregação de dados para telemetria de alta precisão, escalando e condicionando entradas brutas do campo antes de transferi-las para os solucionadores lógicos do sistema. Concessionárias de energia, refinarias petroquímicas e plantas de acionamento mecânico pesado utilizam a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCAG1BAA (DS200TCCAG1BAA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara supervisionar perfis térmicos delicados, circuitos de corrente multicanal e indicadores de estabilidade mecânica rotacional. Ao unificar sinais de campo de múltiplas fontes em uma única estrutura de barramento padronizada, a placa garante comportamento previsível do governador, protege turbinas pesadas rotativas contra oscilações súbitas ou fadiga térmica e minimiza paradas operacionais não planejadas em instalações industriais pesadas.\u003c\/p\u003e\n\u003ch3\u003eCircuitaria Arquitetural \u0026amp; Mapeamento de Sinais\u003c\/h3\u003e\n\u003cp\u003eA engenharia estrutural da\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCAG1BAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegra lógica microprocessada discreta com subcircuitos multifuncionais de aquisição.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLógica de Microcontrolador Integrada:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConta com um processador Intel 80196 embarcado que executa algoritmos independentes de condicionamento de sinal, escalando localmente os dados brutos do campo usando instruções armazenadas em blocos de Memória Programável Somente de Leitura (PROM) apagáveis e encaixáveis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInfraestrutura de Monitoramento Térmico:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncorpora circuitos dedicados de excitação RTD e cálculos de compensação de junção fria. Monitora as variações de resistência do RTD através dos conectores JCC e JDD enquanto traduz sinais de termopar via a interface da placa terminal TBQA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento Dinâmico do Laço de Corrente:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtiliza resistores de carga onboard no caminho do conector JBB para converter correntes de transdutores 4-20 mA em passos de tensão legíveis, enquanto simultaneamente fornece saídas de corrente regulada 4-20 mA pelo conector JAA para alimentar instrumentos remotos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTelemetria do Eixo da Turbina:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHospeda subsistemas especializados de monitoramento do eixo que acompanham continuamente o potencial elétrico e vazamento de corrente ao longo do eixo da turbina, fornecendo telemetria vital de degradação do isolamento para o motor central de E\/S através do barramento 3PL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParâmetros de Hardware \u0026 Índices Operacionais\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cstrong\u003eParâmetro do Sistema\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cstrong\u003eÍndice de Engenharia de Fábrica\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eDesignação do Modelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eDS200TCCAG1BAA (Placa Principal: DS200TCCAG1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eIdentificador da Marca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eGeneral Electric (Placas GE \u0026 Controle de Turbina)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eSérie do Sistema de Controle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eSpeedtronic Mark V (Sub-série TC2000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eAcrônimo Funcional\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003ePlaca TCCA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eLocal de Montagem do Núcleo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eSlot do Chassi de Controle R5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCPU Lógica Onboard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eMicroprocessador Intel 80196 de 16 bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eArquitetura de Armazenamento de Firmware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eMódulos PROM Socketados e Removíveis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 39.1875px;\"\u003e\u003cspan\u003e\u003cstrong\u003eLink de Comunicação Mestre Primário\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 39.1875px;\"\u003e\u003cspan\u003eConector de Barramento de Dados 3PL (Para STCA \/ Motor de E\/S)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 39.1875px;\"\u003e\u003cspan\u003e\u003cstrong\u003eFonte de Entrada Analógica de Campo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 39.1875px;\"\u003e\u003cspan\u003eLaços 4-20 mA, Termopares, RTDs, Monitores de Eixo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eDimensões Físicas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e28.0 x 18.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003ePeso Líquido do Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e0,45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eProteção do Circuito Impresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eRevestimento Industrial Normal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eHierarquia de Revisão de Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eRevisões Funcionais B e A, Revisão de Arte A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eLimites Térmicos Operacionais\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e0 a 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 39.1875px;\"\u003e\u003cspan\u003e\u003cstrong\u003eEntrada de Alimentação Lógica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 39.1875px;\"\u003e\u003cspan\u003ePlugue de Distribuição de Energia 2PL (Fornecido via Placa TCPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0714%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003ePaís de Origem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.0714%; height: 19.5938px;\"\u003e\u003cspan\u003eEstados Unidos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Diagnóstico Técnico\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuais são as funções principais dos jumpers de hardware onboard J1, JP2 e JP3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO jumper J1 controla o status operacional da porta de programação serial RS232 local. O jumper JP2 desativa o oscilador de clock integrado da placa, necessário durante rotinas de benchmark e testes em bancada no nível do cartão. O jumper JP3 é um link dedicado para testes de fábrica e deve permanecer em sua posição padrão de fábrica durante operações normais da turbina.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo a interface do espaço de trabalho do operador está fisicamente conectada aos circuitos de processamento desta placa?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA interface do operador (designada como ) conecta-se à placa DS200TCCAG1BAA usando a placa terminal intermediária CTBA. A placa CTBA ancora os sinais de 4-20 mA, conectando-se à placa TCCA via os conectores de saída JAA e entrada JBB para permitir o fluxo contínuo de dados de exibição para a tela HMI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo a placa TCCA concilia diferentes curvas de resposta térmica para configurações variadas de termopar ou RTD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA placa depende de constantes de configuração de E\/S dirigidas por software em vez de ajustes fixos de componentes. Os engenheiros de campo inserem coeficientes específicos de sensores e tipos de curva no Editor de Configuração de E\/S no terminal HMI. O microcontrolador interno 80196 lê esses registradores constantes para ajustar seus algoritmos de processamento para cada canal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProtocolo de Engenharia de Campo e Manutenção\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransferência do PROM de firmware e precauções contra eletricidade estática:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePara manter a compatibilidade correta do software ao implantar uma placa substituta, você deve mover os módulos PROM originais da placa defeituosa para a unidade substituta. Use uma chave de fenda de lâmina plana para levantar cada extremidade do chip uniformemente do soquete e coloque-o dentro de uma bolsa antiestática. O pessoal deve usar uma pulseira ESD devidamente aterrada durante todo esse procedimento para evitar falhas estáticas latentes na lógica do semicondutor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento da blindagem analógica e separação de sinais:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTodas as conexões analógicas que entram nos conectores JAA, JBB, JCC e JDD devem utilizar condutores blindados de par trançado de alta densidade. A blindagem de cobre deve ser aterrada exclusivamente na barra de aterramento designada na placa terminal. Aterramento flutuante ou em ambas as extremidades introduz loops de potencial de terra, criando ondulações elétricas que podem corromper avaliações delicadas de temperatura por termopar e RTD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegras para desligamento e restrições do conector vestigial:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIsole o plugue de distribuição de energia 2PL antes de deslizar a placa TCCA para dentro ou fora do quadro central R5. Manusear o módulo enquanto o backplane está energizado causa picos de tensão no barramento de dados 3PL, arriscando a corrupção da memória. Além disso, o conector JEE é um layout estrutural vestigial; não conecte fiação externa ou ferramentas de depuração a este terminal durante operações normais.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695408312683,"sku":"DS200TCCAG1BAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ds200tccag1baa-tc2000-common-analog-i-o-board-1rgj3eq3xld_18ef5e77-4d52-4e78-8624-d948bb0ce270.jpg?v=1766134965","url":"https:\/\/www.plcprotech.com\/pt\/products\/ge-mark-v-ds200tccag1baa-tc2000-common-analog-i-o-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}