{"product_id":"ge-multilin-745-w2-p5-g5-hi-transformer-protection-relay","title":"Relé de Proteção de Transformador GE Multilin 745-W2-P5-G5-HI","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e745-W2-P5-G5-HI (745W2P5G5HI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um Relé de Proteção de Transformador baseado em microprocessador de alta velocidade e crítico para segurança, projetado pela General Electric dentro da linha legada do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSistema de Proteção de Transformadores 745\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Construído sob medida para otimizar a vida útil dos ativos de utilidade e controlar parâmetros elétricos severos, esta unidade de hardware gerencia a coordenação diferencial completa em configurações de transformadores com dois enrolamentos. Infraestruturas industriais de processo contínuo de alta capacidade — incluindo grandes usinas de manufatura, usinas termodinâmicas e subestações primárias da rede — dependem do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e745-W2-P5-G5-HI (745W2P5G5HI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara monitorar falhas elétricas voláteis, cenários de sobreexcitação e sobrecargas térmicas. Incorporando laços de proteção especializados como isolamento restrito de falha à terra e bloqueio adaptativo por subtensão, o relé elimina correntes de falha a jusante em milissegundos. Esse isolamento rápido protege transformadores elevadores massivos contra danos dielétricos permanentes, mantém a sincronização do sistema de rede e mitiga paradas não programadas dispendiosas na planta.\u003c\/p\u003e\n\u003ch3\u003eDesdobramento do Sufixo do Modelo\u003c\/h3\u003e\n\u003cp\u003eAs envelopes operacionais precisos, capacidades de entrada e restrições de potência da unidade de proteção\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e745-W2-P5-G5-HI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esão classificadas através de sua matriz alfanumérica de pedidos.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEstrutura Base 745:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifica a arquitetura fundamental de gerenciamento e diagnóstico de transformadores Multilin de alta velocidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeleção de Opção W2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEspecifica um design nativo do sistema configurado para uma topologia de transformador com 2 enrolamentos por fase.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClassificação de Entrada de Fase P5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetermina que as entradas de corrente de fase primária são calibradas de fábrica para um transformador de corrente (TC) secundário padrão de 5 A (Enrolamento 1 = 5 A, Enrolamento 2 = 5 A, Enrolamento 3 = 5 A quando aplicável).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClassificação de Entrada de Terra G5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefine os limiares especializados do canal de entrada do relé de corrente de terra para Enrolamento 1\/2 = 5 A e Enrolamento 2\/3 = 5 A para rastreamento dedicado de falhas de sequência zero.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguração HI Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresenta a variante de alta potência de controle, aceitando amplas janelas operacionais de entrada de 90 a 300 VCC ou 70 a 265 VAC para manter a integridade do circuito durante quedas severas na linha da bateria da subestação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDesempenho Técnico e Índice de Ativos\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMétrica de Proteção\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePadrão Certificado de Especificação de Engenharia\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDesignação do Modelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e745-W2-P5-G5-HI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFabricante da Marca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin \/ GE Grid Solutions (GE Vernova)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinha de Sistema de Controle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSistema de Proteção de Transformador 745\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClassificação do Módulo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelé de Transformador com Microprocessador de Alta Velocidade\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfigurações de Transformador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTopologias de 2 Enrolamentos por Fase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClassificação de Corrente de Fase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePerfil de Entrada Secundária de 5 A (Seleção P5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClassificação de Corrente de Terra\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePerfil de Entrada Secundária de 5 A (Seleção G5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFaixa de Entrada de Tensão\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIngestão Nominal do Relé de 60 a 120 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlimentação de Controle Alta (HI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 a 300 VDC \/ 70 a 265 VAC (Faixa de 48 a 62 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSuporte a Corrente de Sobrecarga\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 segundo a 80 vezes a corrente nominal \/ Contínuo a 3 vezes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Visual Localizada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTela LCD Retroiluminada de 40 Caracteres com Teclado Frontal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTamanho Físico da Placa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23 cm A x 18,1 cm P x 17,8 cm L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso para Envio do Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,8 kg (aprox. 10,58 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJanela de Operação Ambiente\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 a +60 °C (-40 a +140 °F) Faixa Térmica\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLimites de Temperatura de Armazenamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 a +80 °C (-40 a +176 °F) Limites Máximos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTolerâncias de Umidade\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAté 90 por cento de ambiente não condensante\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Proteção de Rede de Subestação e Software\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuais vantagens funcionais a seleção de alimentação de controle HI oferece em relação à opção alternativa LO?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA estrutura de alimentação de controle HI permite que o 745-W2-P5-G5-HI se conecte diretamente com os principais bancos de baterias de alta tensão da concessionária, operando de forma estável em qualquer entrada entre 90 a 300 VDC ou 70 a 265 VAC. Por outro lado, a opção de alimentação de controle LO é restrita a nós de infraestrutura de baixa tensão, operando apenas dentro de faixas mais estreitas de 20 a 60 VDC ou 20 a 48 VAC, tornando o modelo HI muito mais resistente contra quedas de tensão na rede da subestação.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo as equipes de proteção da subestação conectam o hardware do PC para baixar arquivos ou modificar pontos de ajuste ativos?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO relé oferece interfaces físicas separadas dependendo dos seus requisitos de rede. Para programação ponto a ponto imediata, os técnicos se conectam via a porta RS232 no painel frontal diretamente a um laptop executando o conjunto de softwares EnerVista 745. Para redes com múltiplos relés dentro de um gabinete de controle, os links seriais RS485 ou RS422 no painel traseiro devem ser usados para conectar em cadeia a telemetria de volta ao terminal mestre SCADA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEsta configuração específica do modelo pode executar protocolos Ethernet nativos diretamente sobre uma rede óptica?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. Na matriz GE Multilin 745, a capacidade nativa de Ethernet requer uma placa de comunicação opcional indicada por um caractere \"T\" no sufixo final da string. Como esta unidade é uma configuração serial padrão não mapeada (745-W2-P5-G5-HI), a comunicação em rede via Ethernet exige um conversor de protocolo serial-para-Ethernet externo ou uma atualização de hardware para uma variante T-spec.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia \u0026 Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento do Transformador de Corrente (TC) e Conexões nos Terminais:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAo conectar condutores pesados do transformador de corrente secundário nos blocos de terminais P5 e G5 na parte traseira do invólucro 745, verifique se todos os comuns do circuito TC estão interligados e ligados à malha de terra da estação em um único ponto. Certifique-se de que todos os terminais de parafuso estejam apertados com torque máximo de 1,4 N-m (12,4 polegadas-libras). Abrir o circuito primário ativo de um TC durante operações ao vivo do transformador gerará picos de tensão letais, destruindo os transformadores analógicos internos de correspondência do relé.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolamento de Ruído Serial e Diretrizes para Fios Blindados:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAo configurar os links de comunicação traseiros RS485 ou RS422 entre múltiplos relés, utilize cabo blindado de par trançado de alta qualidade com impedância característica de 120 ohms. Faça o aterramento do fio dreno da blindagem de comunicação apenas no painel receptor mestre SCADA. Não aterre a blindagem em múltiplos relés ao longo do barramento serial, evitando que diferenças locais de potencial de terra injetem ruído de comunicação nos registradores seriais.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento Térmico e Restrições de Fluxo de Ar no Painel:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO relé 745 é totalmente certificado para operar dentro de uma faixa térmica ambiente estendida de -40 a +60 °C. Ao montar embutido o invólucro de 9 polegadas de altura em painéis padrão de equipamentos de comutação, certifique-se de que os componentes adjacentes que geram calor — como transdutores de potência ou relés de disparo intermediários — mantenham uma folga física mínima de 10 cm. Verifique se as venezianas de ventilação no chassi permanecem desobstruídas para permitir a convecção passiva do ar e evitar pontos quentes localizados que acelerem o desgaste dos componentes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695407722859,"sku":"745-W2-P5-G5-HI-T","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-multilin-745-w2-p5-g5-hi-t-high-speed-transformer-protection-relay-d5qwpj5qou0_13c963c6-3a53-4b22-818a-db627f216696.jpg?v=1766134947","url":"https:\/\/www.plcprotech.com\/pt\/products\/ge-multilin-745-w2-p5-g5-hi-transformer-protection-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}