{"product_id":"ge-multilin-750-p5-g5-d5-hi-a20-r-e-h-feeder-management-relay","title":"GE Multilin 750-P5-G5-D5-HI-A20-R-E-H Feeder Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 750-P5-G5-D5-HI-A20-R-E-H\u003c\/strong\u003e is a digital feeder protection system engineered for the primary protection, management, and control of distribution feeders. This comprehensive relay offers reliable backup protection for buses, transformers, and transmission lines utilizing a convenient draw-out construction that simplifies maintenance and reduces product lifecycle costs. Equipped with precise built-in metering functions, the device eliminates the requirement for separate auxiliary metering components. It features 5 A phase current inputs, 5 A ground current inputs, and 5 A zero sequence current inputs to accommodate specific electrical system configurations. For automated system monitoring and interfacing, the unit incorporates eight 4 to 20 mA analog outputs. The relay supports standard industrial protocols such as Modbus RTU and DNP 3.0 to facilitate seamless integration into distributed control systems (DCS) and SCADA environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete protection, control, and management functions for distribution feeders in a single integrated unit.\u003c\/li\u003e\n\u003cli\u003eDraw-out construction design allowing for rapid replacement and minimized system downtime.\u003c\/li\u003e\n\u003cli\u003eHighly accurate built-in metering functions that eliminate the need for extra auxiliary metering infrastructure.\u003c\/li\u003e\n\u003cli\u003eEnhanced event recording capabilities including IRIG-B time synchronization, event reports, waveform capture, and data logging.\u003c\/li\u003e\n\u003cli\u003eEight fully programmable, isolated 4 to 20 mA analog outputs for mapping critical system parameters.\u003c\/li\u003e\n\u003cli\u003eBuilt-in simulation and playback features to simplify testing and verification procedures.\u003c\/li\u003e\n\u003cli\u003eFlash memory support for easy product field upgrades and long-term functional adaptability.\u003c\/li\u003e\n\u003cli\u003eHarsh chemical environment protection option providing conformal coating for chemically corrosive and humid applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary protection and control for various distribution feeders.\u003c\/li\u003e\n\u003cli\u003eBackup protection applications for buses, transformers, and transmission lines.\u003c\/li\u003e\n\u003cli\u003eIntegrated asset and I\/O monitoring in utility and industrial electrical networks.\u003c\/li\u003e\n\u003cli\u003eAdvanced automation and control architectures requiring Modbus or DNP 3.0 network communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Code\u003c\/th\u003e\n\u003cth\u003eTechnical Specification Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e750\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model for Feeder Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A Phase Current Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A Ground Current Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A Zero Sequence Current Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEight 4 – 20 mA Analog Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed Breaker Closed LED Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnhanced Display, Larger LCD, and Improved Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarsh Chemical Environment Option (Conformal Coating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin (GE Vernova)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Inputs (P5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Current Inputs (G5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Sequence Current Inputs (D5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Options (HI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs Configuration (A20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEight 4 – 20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Status LED (R)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed breaker closed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnhancements (E)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnhanced display, larger LCD, improved keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection (H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarsh Chemical Environment Option (Conformal Coating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Setup:\u003c\/strong\u003e Ensure the relay is securely panel-mounted utilizing standard cutout parameters intended for the draw-out unit frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection:\u003c\/strong\u003e Establish a clean, low-impedance ground connection to the dedicated chassis grounding terminal to prevent electrical noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e Keep high-current CT inputs and high-voltage VT wiring separated from low-voltage signal cables and communication links to mitigate EMI\/RFI issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e For units with option H, ensure external terminals and seals are securely positioned after mounting to preserve the integrity of the harsh chemical environment conformal coating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695414538603,"sku":"750-P5-G5-D5-HI-A20-R-E-H","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-multilin-750-p5-g5-d5-hi-a20-r-e-h-feeder-management-relay-ds1pt53pb5y_f2f181b7-1d29-4b75-9098-0a2c06457a40.jpg?v=1766135194","url":"https:\/\/www.plcprotech.com\/pt\/products\/ge-multilin-750-p5-g5-d5-hi-a20-r-e-h-feeder-management-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}