{"product_id":"general-electric-is200vturh1baa-mark-vi-primary-turbine-protection-card","title":"General Electric IS200VTURH1BAA Mark VI Primary Turbine Protection Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis printed circuit board assembly acts as the core core hardware-level processing interface for critical safety parameters within turbine control architectures. The \u003cstrong\u003eGE IS200VTURH1BAA\u003c\/strong\u003e, serving as a \u003cstrong\u003ePrimary Turbine Protection Card\u003c\/strong\u003e within the \u003cstrong\u003eMark VI\u003c\/strong\u003e Speedtronic series, is engineered to prevent destructive machinery states by continually executing emergency subsystem routines. This board processes passive pulse rate outputs to evaluate machinery speed profiles, interfaces directly with flame safety devices for gas combustion monitoring, and controls high-speed overspeed trip relays to isolate fuel paths if setpoint limits are crossed. The card communicates across a standardized VME rack frame to exchange protective data matrices with system control processors, offering hardware-enforced protection loops for utility power generators and industrial turbine systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt with a specialized conformal coating to protect circuit traces from high-vibration and industrial cabinet airborne particles\u003c\/li\u003e\n\u003cli\u003eSupports simultaneous speed monitoring from up to four passive pulse rate sensor arrays\u003c\/li\u003e\n\u003cli\u003eInterfaces with up to eight Geiger-Mueller flame detectors for gas turbine applications\u003c\/li\u003e\n\u003cli\u003eControls three independent overspeed trip relays situated on corresponding TRPx terminal boards\u003c\/li\u003e\n\u003cli\u003eFeatures integrated logic channels for induced shaft current monitoring and auto-synchronization loops\u003c\/li\u003e\n\u003cli\u003eOutfitted with front-panel diagnostic LEDs providing clear visual tracking of hardware health and process integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtility-scale steam and gas turbine emergency overspeed trip protection loops\u003c\/li\u003e\n\u003cli\u003eAutomation control, grid synchronization, and main circuit breaker closure sequencing\u003c\/li\u003e\n\u003cli\u003eGas turbine flame monitoring networks using specialized pulse radiation sensors\u003c\/li\u003e\n\u003cli\u003eDynamic industrial power plant asset protection and shaft current mitigation diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS200VTURH1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary Turbine Protection Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Revisions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Revisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackwards-Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFirst two revisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB (Functional), A (Functional), A (Artwork)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Rate Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Passive pulse rate devices (Simplex applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Detector Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Geiger-Mueller flame detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverspeed Trip Relay Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Relay channels (Interfacing with TRPx board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD-Shell Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated front panel electrical connection for specialized interface loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVME Backplane Edge Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-density communication bus interface for power intake and data matrix transport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus LED Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplays localized hardware diagnostic initialization health states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFail LED Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvaluates and indicates critical internal board failures or logic execution blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun LED Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIlluminates continuously when the protective card actively performs firmware sequences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eVME Rack Integration\u003c\/h3\u003e\n\u003cp\u003eThe board is designed to slide directly into a standard VME processor rack. This hardware installation must strictly take place only when the target rack system is fully powered down to avoid diagnostic communication failures or electrical shorting across the backplane traces.\u003c\/p\u003e\n\u003ch3\u003eMechanical Retention\u003c\/h3\u003e\n\u003cp\u003eInsert the module evenly along the card guides. Use the top and bottom integrated extraction levers to firmly press the card inward and completely seat the edge connectors into the backplane plug. Hand-tighten the upper and lower captive panel screws into the frame threads to fully lock the front faceplate in place.\u003c\/p\u003e\n\u003ch3\u003eRelay Topology Adjustment\u003c\/h3\u003e\n\u003cp\u003eWhen deploying within TMR (Triple Modular Redundant) systems, verify that all nine interconnected magnetic relays on the external TRPx terminal board are correctly referenced in software routing. In standard Simplex configurations, ensure only the three primary active relays are assigned to follow the safety trip commands.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695415423339,"sku":"IS200VTURH1BAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is200vturh1baa-mk6-gas-tmr-pk-turbine-card-v4d5xlpak3g_13b8c7d7-6a04-43a3-aa4f-dfccb5b87f12.jpg?v=1766135229","url":"https:\/\/www.plcprotech.com\/pt\/products\/general-electric-is200vturh1baa-mark-vi-primary-turbine-protection-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}