{"product_id":"general-electric-is220ppdah1a-mark-vie-power-distribution-feedback-system-pack","title":"General Electric IS220PPDAH1A Mark VIe Power Distribution Feedback System Pack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PPDAH1A\u003c\/strong\u003e is a power distribution system feedback pack manufactured by GE Energy as part of the Mark VIe Series for turbine control and industrial power distribution systems. This specialised I\/O pack is engineered to condition board feedback signals, accepting up to six inputs from distinct power distribution boards simultaneously. It incorporates automated identification routines, utilizing built-in electronic IDs to scan and determine exactly which power distribution boards are physically wired into the unit. This acquired hardware profiling data is dynamically transmitted over the network to the IONet output to ensure highly accurate status feedback from all connected boards. To secure stable integration with the control architecture, the unit delivers a dual redundant Ethernet interface linking the underlying boards directly to the primary system controllers.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts up to six discrete feedback inputs from different power distribution boards\u003c\/li\u003e\n\u003cli\u003eFunctions as a signal conditioner to stabilize and standardize board feedback indicators\u003c\/li\u003e\n\u003cli\u003eProvides a dual redundant Ethernet interface to establish secure lines to system controllers\u003c\/li\u003e\n\u003cli\u003eIntegrates an electronic ID reader to automatically discover and identify connected boards\u003c\/li\u003e\n\u003cli\u003eSynchronizes scanned board identities with IONet output strings to maintain precise tracking\u003c\/li\u003e\n\u003cli\u003eContains eight active operational and network status LEDs on the front face\u003c\/li\u003e\n\u003cli\u003eUtilizes a conformal circuit coating to maximize protection across harsh industrial sites\u003c\/li\u003e\n\u003cli\u003eEquipped with built-in self-diagnostic routines to ensure uninterrupted internal monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed power distribution status tracking\u003c\/li\u003e\n\u003cli\u003eMain control line power monitoring\u003c\/li\u003e\n\u003cli\u003eHeavy-duty gas or steam turbine control infrastructure\u003c\/li\u003e\n\u003cli\u003ePower generation system loop diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIS220PPDAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003ePPDA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Distribution Feedback System Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eIS220 Standard Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003ePower Distribution Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Circuit Coating\u003c\/td\u003e\n\u003ctd\u003eConformal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Quantity\u003c\/td\u003e\n\u003ctd\u003eEight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003eFive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Type\u003c\/td\u003e\n\u003ctd\u003eSystem Feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Protective Actions\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Reference\u003c\/td\u003e\n\u003ctd\u003eGEH-6721L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e10.0 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e16 x 16 x 16 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBoard Interface Compatibility\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRated Voltage \/ Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eJPDS Control Power Terminal Board\u003c\/td\u003e\n\u003ctd\u003e28 V dc Rating (Mounting Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJPDM Control Power Terminal Board\u003c\/td\u003e\n\u003ctd\u003e28 V dc Rating (Mounting Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJPDB Power Distribution Board\u003c\/td\u003e\n\u003ctd\u003eFeedback Signal Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJPDE Power Distribution Board\u003c\/td\u003e\n\u003ctd\u003eFeedback Signal Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJPDF Power Distribution Board\u003c\/td\u003e\n\u003ctd\u003eFeedback Signal Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Integration:\u003c\/strong\u003e The I\/O pack is built to be mounted directly onto either a JPDS or a JPDM control power terminal board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e Verify that the underlying terminal board supply maintains a nominal 28 V dc rating prior to securing the pack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Alignment:\u003c\/strong\u003e Connect up to six compatible power distribution boards (such as JPDB, JPDE, or JPDF); the module will automatically read their electronic IDs upon system initialization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Networking:\u003c\/strong\u003e Utilise both onboard network interfaces to hook up the dual redundant Ethernet paths, ensuring fault-tolerant communication back to the main system controllers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695419191659,"sku":"IS220PPDAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220ppdah1a-feedback-i-o-pack-sr2fp1ncqfv_0dbb6733-ad4c-4eb5-9c0c-34d5afaedadf.jpg?v=1766135342","url":"https:\/\/www.plcprotech.com\/pt\/products\/general-electric-is220ppdah1a-mark-vie-power-distribution-feedback-system-pack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}