{"product_id":"hima-h41q-h51q-f-3331-8-channel-safety-output-module","title":"Módulo de Saída de Segurança 8 Canais HIMA H41q\/H51q F 3331","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF 3331 (F3331)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um módulo de saída relacionado à segurança, de alta confiabilidade e com 8 canais, desenvolvido pela HIMA para uso em sistemas de controle críticos que exigem a Classe de Requisito AK 1 a 6. Este módulo é fundamental em Sistemas Instrumentados de Segurança (SIS) nas indústrias de processamento químico, submarino e farmacêutico, onde o isolamento seguro e as capacidades integradas de desligamento são essenciais. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF 3331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuporta cargas resistivas e indutivas de até 500 mA (12 W) e foi projetado especificamente para evitar sinais de saída não intencionais em caso de interrupção da alimentação L-. Ao fornecer testes automatizados contínuos e monitoramento da linha, garante que seus circuitos de segurança permaneçam funcionais, reduzindo significativamente o Número de Prioridade de Risco (RPN) dos seus ativos automatizados.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF 3331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetado com uma arquitetura \"testável\", o que significa que realiza autodiagnósticos sem interromper a lógica do processo. Seu DNA de segurança é construído em torno de três pilares principais:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesligamento de Segurança Integrado:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCircuitos em nível de hardware garantem que o módulo possa atingir um estado desenergizado sob demanda ou detecção de falha interna.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRotinas Abrangentes de Teste:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo executa um \"teste de bit em movimento\" para verificar interferências cruzadas e capacidade de comutação, além de um recurso de leitura que monitora os sinais de saída (limite de sinal 0 ≤ 6,5 V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoramento da Linha:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo supervisiona ativamente a conexão com o dispositivo de campo, detectando curtos-circuitos (acionamento entre 0,75 e 1,5 A) e interrupções na linha (monitorando corrente entre 0,5 e 9,5 mA).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF 3331\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCanais de Saída\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Canais, Testável\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClasse de Requisito de Segurança\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAK 1 a 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacidade de Carga (Resistiva\/Indutiva)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAté 500 mA (12 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacidade de Carga para Lâmpadas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAté 4 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eQueda de Tensão Interna\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMáx. 2 V a 500 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProteção contra Curto-Circuito\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrada (0,75 a 1,5 A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDuração do Sinal de Teste\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMáx. 200 microssegundos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRequisito de Espaço\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 TE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia (5V DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia (24V DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180 mA (mais corrente da carga)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo o módulo lida com uma falha de \"sinal 0\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO ponto de operação de leitura para um sinal 0 é ≤ 6,5 V. É importante notar que, se uma falha causar aumento da tensão, mas permanecer abaixo desse limite de 6,5 V, o sistema não a detectará como uma falha de nível alto.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO que acontece se houver uma interrupção na alimentação L-?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF 3331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetado para que nenhum sinal de saída seja possível se a alimentação L- estiver interrompida, garantindo uma condição à prova de falhas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExiste um limite para o comprimento da fiação de campo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim, a resistência máxima admissível da linha (combinada de ida e volta) é de 11 Ohm. Ultrapassar essa resistência pode interferir na capacidade do módulo de monitorar com precisão interrupções e curtos-circuitos na linha.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBalanceamento de Carga e Gestão de Calor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmbora o módulo seja classificado para 500 mA por canal, a dissipação total de energia a 24 VDC pode atingir 180 mA mais a carga combinada. Garanta que o gabinete tenha ventilação adequada por convecção, pois calor ambiente excessivo (acima de 60 °C) pode alterar as tolerâncias dos componentes e afetar o ponto de disparo por subtensão (normalmente ≤ 16 V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção para Carga Indutiva:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara cargas indutivas, embora o módulo seja classificado para 12 W, recomendamos a instalação de diodos flyback externos no lado da carga para aplicações de alta frequência, a fim de proteger ainda mais o circuito integrado de desligamento de segurança contra picos de força contraeletromotriz (back-EMF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransparência do Sinal de Teste:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA duração do sinal de teste é extremamente curta (máx. 200 microssegundos). Embora isso seja transparente para a maioria dos atuadores industriais e lâmpadas, certifique-se de que quaisquer interfaces eletrônicas de alta velocidade a jusante sejam compatíveis com esse pulso diagnóstico transitório para evitar \"flicker\" ou acionamentos falsos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695403069803,"sku":"F3331","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-f3331-safety-related-output-module-g5gexcxd0sq_49ef2f0c-eded-449d-9b9a-b54cab21c05b.jpg?v=1766133869","url":"https:\/\/www.plcprotech.com\/pt\/products\/hima-h41q-h51q-f-3331-8-channel-safety-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}