{"product_id":"honeywell-51109693-100b-universal-control-network-ucn-4-port-drop-cable-tap-ground-module","title":"Honeywell 51109693-100B Módulo de Aterramento para Cabo Drop de 4 Portas da Rede de Controle Universal (UCN)","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003eHoneywell 51109693-100B\u003c\/strong\u003e é um componente especializado de interface de rede projetado para a Rede de Controle Universal (UCN) dentro dos Sistemas de Controle Distribuído (DCS) legados TotalPlant Solution (TPS) e TDC 3000. Este módulo serve como um robusto \u003cstrong\u003ebloco de aterramento para tap de cabo de queda de 4 portas\u003c\/strong\u003e, facilitando o acoplamento seguro da interface coaxial e infraestrutura de aterramento precisa para linhas críticas de dados de controle de alta velocidade.\u003c\/p\u003e\n\u003cp\u003eProjetado estritamente para ambientes rigorosos de controle industrial, o \u003cstrong\u003e51109693-100B\u003c\/strong\u003e Estabelece conexões robustas de ramificação da linha tronco principal da UCN para nós individuais, como Gerenciadores de Processo de Alto Desempenho (HPM), Módulos de Interface de Rede (NIM) ou Gerenciadores de Processo Avançados (APM). Ao fornecer terminações de blindagem de alta integridade e caminhos para descarga estática, o módulo previne ativamente a propagação de ruído modo comum, interrupções por loop de terra e atenuação de sinal ao longo do segmento da rede. Sua arquitetura passiva de grau industrial assegura operações ininterruptas da camada física e correspondência uniforme de impedância necessária para sincronização contínua de processos industriais multinós.\u003c\/p\u003e\n\u003ch3\u003eCaracterísticas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eApresenta uma infraestrutura integrada de \u003cstrong\u003econexão de cabo de queda de 4 portas\u003c\/strong\u003e que permite quedas de transceptores duplas ou multinós a partir de um ponto localizado.\u003c\/li\u003e\n\u003cli\u003eIncorpora uma interface dedicada de barra de aterramento de baixa resistência para drenar interferências EMI\/RFI induzidas longe dos núcleos coaxiais.\u003c\/li\u003e\n\u003cli\u003eMantém parâmetros rigorosos de atenuação da camada física para garantir a integridade do sinal em topologias estendidas da rede TDC 3000.\u003c\/li\u003e\n\u003cli\u003eProjetado com alumínio fundido resistente ou material de blindagem especializado para proteger as junções internas de alta frequência contra ruído industrial ambiente.\u003c\/li\u003e\n\u003cli\u003eEmprega mecanismos de terminação BNC de alta precisão ou coaxiais especializados que minimizam perdas de inserção e coeficientes de reflexão.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalação da camada física do Sistema de Controle Distribuído (DCS) em plantas petroquímicas e refinarias de petróleo que utilizam as plataformas Honeywell TDC 3000 \/ TPS.\u003c\/li\u003e\n\u003cli\u003eAterramento especializado e distribuição de queda para comunicações de alta confiabilidade entre subsistemas HPM e Módulos de Interface de Rede (NIM).\u003c\/li\u003e\n\u003cli\u003eRedes de utilidade para geração de energia que requerem topologias de barramento de campo isoladas e imunes a ruídos em longas distâncias físicas.\u003c\/li\u003e\n\u003cli\u003eLinhas de processamento de celulose, papel e manufatura pesada que utilizam infraestruturas legadas de controle de processo corporativo baseadas em coaxial.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificações\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNúmero do Modelo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51109693-100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentificador Alternativo da Peça\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReferência do Kit 51201395-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo de Dispositivo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBloco de Aterramento para Tap de Cabo de Queda da Rede de Controle Universal (UCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguração da Porta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacidade de Distribuição \/ Queda de 4 Portas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface de Rede\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTap de Linha Drop do Cabo Coaxial Tronco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePaís de Origem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEUA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões Físicas (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,0 cm x 9,8 cm x 4,0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso Líquido\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstrução do Invólucro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInvólucro industrial blindado de alta densidade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePino do Conector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTronco Entrada\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSegmento de Entrada do Cabo Coaxial Primário UCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTronco Saída\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuação da Saída do Cabo Coaxial Primário UCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta Drop 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConexão da Linha Drop do Ramo do Nó 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta Drop 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConexão da Linha Drop do Ramo do Nó 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta Drop 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConexão da Linha Drop do Ramo do Nó 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta Drop 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConexão da Linha Drop do Ramo do Nó 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParafuso GND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConexão de Aterramento de Baixa Impedância como Referência Principal de Terra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequisitos de Aterramento\u003c\/strong\u003e: Fixe o terminal principal de aterramento externo diretamente à barra de terra limpa local de instrumentação por meio de uma fita trançada de cobre de baixa impedância. Evite encadear caminhos de terra através de múltiplas estruturas mecânicas separadas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlindagem e Isolamento EMI\u003c\/strong\u003e: Garanta a continuidade completa da blindagem externa coaxial através das braçadeiras dos terminais para evitar vazamento de RF e entrada de ruído industrial de modo comum em alta frequência.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecauções no Roteamento do Cabo\u003c\/strong\u003e: Passe os cabos tronco de entrada e saída por dutos dedicados de baixa tensão para dados, mantendo uma distância mínima de 300mm de linhas de alimentação AC de alta tensão ou saídas de inversores de frequência variável.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaio de Curvatura do Cabo Drop\u003c\/strong\u003e: Siga rigorosamente as especificações OEM do cabo coaxial quanto aos raios mínimos de curvatura durante a instalação dentro dos painéis locais de marshaling para evitar deformação dielétrica estrutural.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerguntas Frequentes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a função principal do 51109693-100B dentro de uma rede DCS da Honeywell?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO módulo atua como uma junção drop localizada de 4 portas e bloco de aterramento de sinal na Rede de Controle Universal, conectando troncos coaxiais primários a transceptores de nó sem degradar as características de impedância.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEsta unidade requer circuitos de alimentação ativos externos para funcionar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão, esta é uma unidade totalmente passiva, mecânica e elétrica, projetada para divisão de sinal, manutenção de impedância e mitigação de aterramento em linhas coaxiais.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOs ports drop não utilizados podem ficar abertos durante a operação ativa do sistema?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão, todos os terminais drop não utilizados em linhas de rede ativas devem ser equipados com terminadores de impedância de alta frequência compatíveis para evitar reflexões de sinal e possíveis erros de corrupção de quadros.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQual orientação de montagem é ideal para maximizar a resistência ambiental?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO módulo deve ser montado dentro de um invólucro de controle à prova de poeira com classificação NEMA\/IP, preferencialmente com os conectores drop voltados para baixo para evitar a entrada de umidade ou acúmulo de detritos dentro dos barris fêmea.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667749532011,"sku":"51109693-100B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51109693-100b-bracket-un3vk2whkyz_3aa2fb77-65e2-41d3-9b7d-adeb1d10bc9a.jpg?v=1765501531","url":"https:\/\/www.plcprotech.com\/pt\/products\/honeywell-51109693-100b-universal-control-network-ucn-4-port-drop-cable-tap-ground-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}