{"product_id":"honeywell-8c-tpoxa1-51307153-175-experion-series-8-profibus-gateway-iota-coated","title":"Gateway PROFIBUS IOTA Honeywell 8C-TPOXA1 51307153-175 da Série Experion 8, revestido","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eHoneywell 8C-TPOXA1\u003c\/strong\u003e (Número de peça \u003cstrong\u003e51307153-175\u003c\/strong\u003e) é um conjunto de terminação de entrada\/saída (IOTA) com revestimento conformal, projetado especificamente para a plataforma do sistema de controle distribuído (DCS) \u003cstrong\u003eHoneywell Experion LX Série 8\u003c\/strong\u003e. Ele serve como interface física de montagem e cabeamento para o \u003cstrong\u003emódulo gateway PROFIBUS 8C-IP0102 da Honeywell (PGM)\u003c\/strong\u003e, habilitando links de comunicação fieldbus entre a instrumentação de campo e o sistema controlador.\u003c\/p\u003e\n\u003cp\u003eEsta IOTA funciona como o ponto de conexão essencial para cabos externos de comunicação de campo, distribuição de energia e roteamento de interfaces em nível de sistema. Construída com revestimento conformal de fábrica, a \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e foi projetada para suportar ambientes industriais de processamento severos, evitando contaminação e corrosão no nível da placa.\u003c\/p\u003e\n\u003ch3\u003eRecursos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface gateway dedicada:\u003c\/strong\u003e Projetada especificamente para hospedar o \u003cstrong\u003emódulo gateway PROFIBUS 8C-IP0102\u003c\/strong\u003e na arquitetura Experion Série 8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção por revestimento conformal:\u003c\/strong\u003e A construção com placa de circuito revestida oferece maior resistência contra poluentes industriais transportados pelo ar e umidade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConectividade integrada:\u003c\/strong\u003e Possui portas Ethernet RJ-45 de enlace duplo FTE-A e FTE-B, além de terminais de interface de rede PBLink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacidade de endereçamento:\u003c\/strong\u003e Incorpora três interruptores rotativos de índice de dispositivo FTE diretamente no conjunto para identificação do nó de hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolamento do barramento do sistema:\u003c\/strong\u003e Possui hardware de interface de montagem aterrado conectado à barra de barramento COM do sistema para garantir a integridade adequada do aterramento.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegração de fieldbus para controle de processos:\u003c\/strong\u003e Hospeda módulos gateway PROFIBUS que conectam instrumentação inteligente aos controladores DCS Experion Série 8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbientes de processamento corrosivos:\u003c\/strong\u003e Ideal para instalação em instalações químicas, de petróleo e gás ou de manufatura que exigem hardware de controle com revestimento conformal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubsistemas de rede industrial:\u003c\/strong\u003e Interfaceia dispositivos de campo com topologias de rede de controle de alta disponibilidade.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFabricante\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003e8C-TPOXA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de peça\u003c\/td\u003e\n\u003ctd\u003e51307153-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de produto\u003c\/td\u003e\n\u003ctd\u003eIOTA gateway PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSérie\u003c\/td\u003e\n\u003ctd\u003eSérie Experion LX 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevestimento\u003c\/td\u003e\n\u003ctd\u003eCom revestimento isolante\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão de operação\u003c\/td\u003e\n\u003ctd\u003e24 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente máxima nominal\u003c\/td\u003e\n\u003ctd\u003e20 A (subsistema da placa de conexão)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura ambiente de operação\u003c\/td\u003e\n\u003ctd\u003e0 °C a +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de armazenamento\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidade operacional\u003c\/td\u003e\n\u003ctd\u003e5% a 95% de UR (sem condensação)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibração\u003c\/td\u003e\n\u003ctd\u003e10–57 Hz (deslocamento de 0,075 mm), 57–150 Hz (carga de 1 G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChoque mecânico\u003c\/td\u003e\n\u003ctd\u003e15 G em 3 eixos (duração de 11 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Conector\u003c\/th\u003e\n\u003cth\u003eFunção\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTE-A (RJ-45)\u003c\/td\u003e\n\u003ctd\u003eConexão do enlace primário da rede Ethernet tolerante a falhas FTE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTE-B (RJ-45)\u003c\/td\u003e\n\u003ctd\u003eConexão do enlace secundário da rede Ethernet tolerante a falhas FTE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePortas PBLink\u003c\/td\u003e\n\u003ctd\u003eConexões dos terminais do cabo da rede PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChaves de índice do dispositivo\u003c\/td\u003e\n\u003ctd\u003eTrês chaves rotativas para definir o endereço do nó de rede do hardware FTE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAterramento COM do sistema\u003c\/td\u003e\n\u003ctd\u003eInterface de conexão de aterramento à barra de barramento COM do gabinete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de instalação\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerifique se a fonte de alimentação do sistema está isolada ou se o sistema está fora de operação antes da montagem.\u003c\/li\u003e\n\u003cli\u003eConfirme o número de peça do hardware da IOTA e certifique-se de que o revestimento isolante esteja de acordo com os requisitos de instalação.\u003c\/li\u003e\n\u003cli\u003eMonte a IOTA no trilho de canal do gabinete usando os parafusos, arruelas e espaçadores específicos.\u003c\/li\u003e\n\u003cli\u003eAperte o parafuso de aterramento no lado direito da IOTA para garantir a conexão à barra de barramento COM do gabinete.\u003c\/li\u003e\n\u003cli\u003eCertifique-se de que os quatro parafusos principais de montagem estejam apertados uniformemente, sem causar deformação na placa.\u003c\/li\u003e\n\u003cli\u003eConecte o cabo Cat5 amarelo ao conector FTE-A e o cabo Cat5 verde ao conector FTE-B.\u003c\/li\u003e\n\u003cli\u003eConecte os cabos do fieldbus PBLink aos respectivos pontos de conexão.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eRecomendações de configuração e substituição\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação do endereço:\u003c\/strong\u003e Antes de ligar o equipamento, ajuste as três chaves rotativas de índice do dispositivo FTE para corresponder exatamente ao endereço do nó da unidade original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncaixe do módulo:\u003c\/strong\u003e Ao instalar o módulo gateway 8C-IP0102 na IOTA, certifique-se de que os conectores da borda da placa se encaixem corretamente antes de apertar os parafusos de retenção.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarga do sistema:\u003c\/strong\u003e Após substituir o hardware, execute a operação \"Carregar com conteúdo\" no Control Builder para atualizar os parâmetros operacionais.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformidade e certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiretiva de Baixa Tensão (LVD):\u003c\/strong\u003e EN 61010-1:2010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiretiva EMC:\u003c\/strong\u003e EN 61326-1:2006, IEC 61326-1:2005\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668000207211,"sku":"8C-TPOXA1 51307153-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tpoxa1-51307153-175-profibus-gateway-module-kevuqr2u2as_08b6b731-76d7-4c30-90e9-28bb1fb2fa1c.jpg?v=1765504993","url":"https:\/\/www.plcprotech.com\/pt\/products\/honeywell-8c-tpoxa1-51307153-175-experion-series-8-profibus-gateway-iota-coated","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}