{"product_id":"honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module","title":"Módulo de entrada analógica de alto nível Honeywell CC-PAIX01 51405038-275 da série C do Experion PKS","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003eHoneywell CC-PAIX01\u003c\/strong\u003e (Número da peça \u003cstrong\u003e51405038-275\u003c\/strong\u003e) é um módulo de Entrada Analógica de Alto Nível (HLAI) de 16 canais, projetado para a família de E\/S Series C do Honeywell Experion PKS. Desenvolvido para fazer a interface direta com um controlador Honeywell C300 por meio da rede I\/O Link dedicada, o módulo fornece condicionamento de sinais de alta densidade e conversão A\/D para transmissores de campo industriais padrão de corrente e tensão analógicas.\u003c\/p\u003e\n\u003cp\u003eOperando sob o controle do controlador C300 com o bloco de função IOM AI-HL no Control Builder, o \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e processa os sinais de campo recebidos independentemente do ciclo de execução do controlador principal. O módulo oferece suporte a configurações de entrada diferencial nos canais 13 a 16, além de entradas de alto nível de terminação simples, proporcionando flexibilidade de sinal e supressão de ruído para loops de processo críticos.\u003c\/p\u003e\n\u003cp\u003eProjetado para ambientes exigentes de controle de processos, o módulo \u003cstrong\u003e51405038-275\u003c\/strong\u003e é instalado diretamente em Conjuntos de Terminação de Entradas e Saídas (IOTAs) Series C. Oferece redundância de hardware quando instalado em placas IOTA redundantes compatíveis, permitindo a comutação automática e o monitoramento contínuo do processo sem interrupções. Observe que o modelo \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e foi oficialmente substituído pelo modelo \u003ca href=\"\/pt\/products\/honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart\"\u003e\u003cstrong\u003eCC-PAIX02\u003c\/strong\u003e\u003c\/a\u003e, que amplia o suporte a entradas diferenciais para todos os 16 canais.\u003c\/p\u003e\n\u003ch3\u003eRecursos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Canais de Alto Nível:\u003c\/strong\u003e Fornece 16 canais de entrada projetados para aceitar sinais analógicos de alto nível de transmissores de campo de 2 fios e autoalimentados.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntradas Diferenciais Selecionáveis:\u003c\/strong\u003e Oferece suporte a conexões de sinais de entrada diferenciais nos canais 13 a 16 para maior rejeição de ruído em modo comum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegração com C300 e I\/O Link:\u003c\/strong\u003e Comunica-se nativamente com controladores C300 pela rede I\/O Link por meio do bloco de função AI-HL no Control Builder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuporte à Redundância:\u003c\/strong\u003e Oferece suporte completo a configurações de hardware redundantes em IOTAs Series C designadas, mantendo a disponibilidade do processo durante a manutenção de um único módulo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign com Troca a Quente:\u003c\/strong\u003e É instalado em IOTAs Series C com um design de inserção angulada, permitindo a remoção e substituição online sob alimentação, sem interferir na fiação de campo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnóstico Integrado:\u003c\/strong\u003e Integra recursos de autodiagnóstico ao monitoramento do software CTools para informar, em tempo real, a integridade do hardware e o status do firmware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoramento Contínuo de Processos:\u003c\/strong\u003e Faz a interface entre transmissores de campo padrão de corrente e tensão de alto nível e sistemas de controle Experion PKS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAquisição de Sinais Diferenciais:\u003c\/strong\u003e Conecta loops analógicos ruidosos ou não isolados nos canais 13 a 16 para eliminar interferências de loop de terra.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRealimentação da malha de controle:\u003c\/strong\u003e Fornecimento de variáveis de processo analógicas de alta densidade (PV) para malhas de vazão, pressão, temperatura e nível gerenciadas por controladores C300.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações técnicas\u003c\/h3\u003e\n\u003ch4\u003eGeral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFabricante\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo exato\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero da peça\u003c\/td\u003e\n\u003ctd\u003e51405038-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSérie\u003c\/td\u003e\n\u003ctd\u003eE\/S Series C do Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de produto\u003c\/td\u003e\n\u003ctd\u003eMódulo de entrada analógica de alto nível (não HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibilidade do controlador\u003c\/td\u003e\n\u003ctd\u003eControlador Honeywell C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNome do bloco IOM\u003c\/td\u003e\n\u003ctd\u003eAI-HL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo sucessor\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEntrada \/ Saída\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de canais\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de sinal de entrada\u003c\/td\u003e\n\u003ctd\u003eCorrente \/ tensão de alto nível (não HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanais de entrada diferencial\u003c\/td\u003e\n\u003ctd\u003eCanais 13 a 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface de rede\u003c\/td\u003e\n\u003ctd\u003eI\/O Link Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMétodo de configuração\u003c\/td\u003e\n\u003ctd\u003eHoneywell Control Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eRecursos operacionais\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundância\u003c\/td\u003e\n\u003ctd\u003eCompatível com placas IOTA redundantes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo de inicialização (perda de alimentação do módulo)\u003c\/td\u003e\n\u003ctd\u003e10 segundos (+\/- 25%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesempenho de comutação do módulo\u003c\/td\u003e\n\u003ctd\u003eEquivalente ao tempo de comutação de E\/S do PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConector de borda da placa traseira\u003c\/td\u003e\n\u003ctd\u003eConecta-se diretamente ao conjunto de terminação de entrada e saída (IOTA) Series C para alimentação, barramento do backplane e sinais de campo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Link Series C\u003c\/td\u003e\n\u003ctd\u003eLink de comunicação serial gerenciado pelo controlador C300 para transferência de dados e programação do módulo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de instalação\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspeção pré-instalação:\u003c\/strong\u003e Confirme o número exato da peça \u003cstrong\u003e51405038-275\u003c\/strong\u003e na etiqueta lateral do módulo e inspecione os pinos do conector físico quanto a danos antes da instalação.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontagem da IOTA:\u003c\/strong\u003e Certifique-se de que o carrier IOTA Series C de destino esteja fixado com segurança dentro do gabinete e devidamente conectado ao terra de proteção.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInserção do módulo:\u003c\/strong\u003e Alinhe o gabinete do módulo com os trilhos-guia do slot IOTA de destino. Deslize o módulo no ângulo padrão de inclinação de 18 graus até que as travas de retenção se encaixem firmemente.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação da fiação de campo:\u003c\/strong\u003e Encaminhe os fios do sinal de entrada de corrente ou tensão analógica de alto nível aos terminais correspondentes na IOTA. Certifique-se de que as fontes de sinal diferencial estejam corretamente atribuídas aos canais 13 a 16.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação do I\/O Link:\u003c\/strong\u003e Verifique se os conectores do cabo do I\/O Link no carrier IOTA estão firmes e se o jumper de endereço físico correto está atribuído, correspondendo à configuração do software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguração \/ Comissionamento \/ Substituição\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguração do Control Builder:\u003c\/strong\u003e Atribua um bloco de módulo AI-HL sob o bloco mestre IOLINK correspondente no Honeywell Control Builder, correspondendo ao endereço de hardware atribuído na IOTA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstituição de módulo redundante:\u003c\/strong\u003e Ao substituir um módulo \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e de revisão mais antiga em um par redundante, verifique os níveis de revisão do hardware. Para sistemas que executam o Experion PKS R310 ou posterior, certifique-se de que o nível do patch do controlador esteja atualizado antes de emparelhar revisões de hardware mais antigas (rev \u0026lt;=K) com revisões mais novas (rev \u0026gt;=M).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação da comutação online:\u003c\/strong\u003e Após inserir um módulo de substituição em um slot IOTA energizado, monitore o CTools para confirmar que a sincronização do firmware foi concluída e que o status do módulo mudou para verde\/ativo.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667736981867,"sku":"CC-PAIX01 51405038-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paix01-51405038-275-analog-input-module-hknbcxbtnph_4f3b11b1-8363-4f10-bee1-164b1ceb123a.jpg?v=1765501331","url":"https:\/\/www.plcprotech.com\/pt\/products\/honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}