{"product_id":"honeywell-experion-pks-cc-pcnt02-51454551-275-c300-controller-1","title":"Honeywell Experion PKS CC-PCNT02 (51454551-275) Controlador C300","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PCNT02 (51454551-275)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProcessador de Controle C300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ede alto desempenho projetado para a plataforma\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Série C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Embora compartilhe a mesma lógica central de controle dos modelos da Série 8 (8C), a versão Série C se destaca pelo seu formato horizontal e pela integração com o Conjunto de Terminação de Entrada e Saída da Série C (IOTA). Como o \"cérebro\" do DCS, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PCNT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecuta controle regulatório, lógica de alta velocidade e procedimentos sequenciais de lote. Este número de peça específico,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51454551-275\u003c\/strong\u003e, indica que a unidade é\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRevestida Conformal G3\u003c\/strong\u003e, oferecendo uma defesa robusta contra contaminantes atmosféricos corrosivos em indústrias como refinarias, celulose e papel, e processamento químico.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eA arquitetura do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PCNT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetada para alta disponibilidade e processamento de dados em alta velocidade.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Horizontal da Série C\u003c\/strong\u003e: Otimizado para montagem em rack horizontal, conectando-se ao IOTA por meio de um conector multipino de alta densidade para comunicação estável e distribuição de energia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Tolerante a Falhas (FTE)\u003c\/strong\u003e: Utiliza portas FTE duplas redundantes para comunicação segura e de alta velocidade entre o controlador, servidores e outros nós pares na rede.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevestimento Conformal G3\u003c\/strong\u003e: O sufixo \"275\" garante que o circuito interno atende aos padrões ISA S71.04 Classe G3, protegendo contra corrosão causada por H2S, Cl2 e alta umidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExecução Determinística\u003c\/strong\u003e: Suporta um Ambiente de Execução de Controle (CEE) configurável, permitindo períodos de execução de loop tão rápidos quanto 50 ms para respostas críticas do processo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundância Nativa\u003c\/strong\u003e: Suporta redundância de hardware 1-para-1. Em um par redundante, o controlador secundário mantém um \"espelho\" em tempo real da memória do primário para uma troca instantânea e sem interrupções.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-PCNT02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNúmero da Peça\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454551-275\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Série C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Processador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcessador de Controle C300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevestimento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevestido Conformal G3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemória\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlash de alta densidade e RAM não volátil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C a 50°C (Temperatura interna do gabinete)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComunicação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePortas FTE duplas, Portas de Link I\/O duplas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEntrada de Energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (via IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a diferença entre o CC-PCNT01 e o CC-PCNT02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO CC-PCNT02 é uma revisão de hardware modernizada que oferece melhor gerenciamento de memória e maior eficiência no processamento interno. É a substituição padrão para o CC-PCNT01 mais antigo na maioria dos sistemas Experion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso misturar um CC-PCNT01 e um CC-PCNT02 em um par redundante?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. Pares redundantes devem ser compostos por versões idênticas de hardware (por exemplo, duas unidades PCNT02) para garantir sincronização e tempo de execução idênticos.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO CC-PCNT02 suporta I\/O da Série 8 (8C)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. Através da comunicação Link I\/O, um controlador C300 da Série C pode gerenciar módulos I\/O da Série 8, desde que a versão do software e a topologia do Link I\/O estejam configuradas corretamente no Experion Control Builder.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontagem do IOTA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertifique-se de que o CC-PCNT02 esteja firmemente encaixado no IOTA da Série C e que os mecanismos de travamento estejam totalmente engajados. Uma conexão solta na interface do IOTA é uma causa comum de alarmes \"Módulo Ausente\" ou \"Falha no Link I\/O\".\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabeamento de Redundância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara configurações redundantes, o cabo de redundância deve ser conectado entre os IOTAs primário e secundário. Sempre verifique o status \"Sincronizado\" no Display de Status do Sistema (SSD) antes de realizar qualquer manutenção de hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiação de Rede:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse apenas cabos FTE certificados pela Honeywell. Garanta que as redes \"Amarela\" e \"Verde\" estejam fisicamente isoladas para manter a verdadeira tolerância a falhas. A fiação cruzada incorreta resultará em um alarme de \"Falha na Rede Secundária\".\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRetenção de Dados:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmbora o CC-PCNT02 utilize RAM não volátil, é recomendável realizar um \"Checkpoint para Flash\" após qualquer alteração significativa na estratégia para garantir que o controlador possa se recuperar autonomamente após uma perda total de energia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668037202283,"sku":"CC-PCNT02 51454551-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-pcnt02-51454551-275-controller-module-ox1dtnomdqs_b76e6b5b-b921-45b1-8cd8-46fe20d296c8.jpg?v=1765505395","url":"https:\/\/www.plcprotech.com\/pt\/products\/honeywell-experion-pks-cc-pcnt02-51454551-275-c300-controller-1","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}