{"product_id":"honeywell-mu-tdor22-51309150-125-digital-output-relay-field-termination-assembly","title":"Conjunto de terminação de campo de relé de saída digital Honeywell MU-TDOR22 51309150-125","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003eHoneywell MU-TDOR22\u003c\/strong\u003e (Nº do conjunto \u003cstrong\u003e51309150-125\u003c\/strong\u003e) é um conjunto de terminação de campo (FTA) de saída digital por relé de 16 pontos e 240 VCA, projetado para integração às arquiteturas DCS Honeywell TotalPlant Solution (TPS), Process Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM) e Enhanced High Performance Process Manager (EHPM). Atuando como uma interface crítica entre os processadores de saída digital (IOPs) e os atuadores no nível de campo, o módulo fornece contatos de relé galvanicamente isolados, projetados para comutar cargas de CA e CC de alta tensão.\u003c\/p\u003e\n\u003cp\u003eA arquitetura central do \u003cstrong\u003eMU-TDOR22\u003c\/strong\u003e conta com canais de saída de relé eletromagnéticos ou de estado sólido que proporcionam isolamento físico entre a lógica interna de baixa tensão do sistema e os equipamentos de campo. Essa configuração protege os componentes eletrônicos do sistema de controle contra ruídos elétricos, transientes de tensão e condições de falha no lado de campo. O conjunto faz interface com IOPs de saída digital Honeywell padrão de 32 ou 16 pontos por meio de cabos de interface do sistema padrão com até 50 metros de comprimento, decodificando os comandos de saída do sistema em fechamentos de contatos secos ou saídas de comutação alimentadas para dispositivos industriais de alta carga.\u003c\/p\u003e\n\u003cp\u003eProjetado para ambientes de processo exigentes, o conjunto \u003cstrong\u003eMU-TDOR22\u003c\/strong\u003e (51309150-125) controla diretamente elementos finais de controle de alta potência, incluindo partidas de motores, solenoides, painéis indicadores, sirenes de alarme e circuitos de intertravamento. Os blocos de terminais montados no cartão acomodam a fiação de campo robusta, enquanto os fusíveis e as redes de supressão integrados protegem os circuitos da fiação de campo contra retornos indutivos e sobrecargas de corrente.\u003c\/p\u003e\n\u003cp\u003eQuando instalado em gabinetes TPS padrão, o cartão opera perfeitamente em configurações de E\/S redundantes ou não redundantes, mantendo a execução determinística das atualizações independentemente da carga de processamento do controlador. Seu layout robusto, alto grau de isolamento dielétrico e compatibilidade com unidades Honeywell Standby Manual padrão garantem a continuidade operacional e a alta disponibilidade do sistema durante a manutenção on-line ou a substituição de módulos.\u003c\/p\u003e\n\u003ch3\u003eRecursos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface de relé de alta tensão:\u003c\/strong\u003e Fornece 16 canais de relé discretos projetados para aplicações de comutação de alta potência em 240 VCA em ambientes de DCS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolamento galvânico:\u003c\/strong\u003e Oferece isolamento óptico e mecânico robusto entre os circuitos de campo e a lógica interna do controlador para evitar loops de terra e proteger os componentes eletrônicos do sistema.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexibilidade no gerenciamento de cargas de contato:\u003c\/strong\u003e Suporta cargas de campo de CA e CC de alta corrente, sendo ideal para o acionamento direto de contatoores de motores, solenoides e atuadores para serviços pesados.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção de circuito integrada:\u003c\/strong\u003e Inclui fusíveis individuais por canal e redes de supressão de contatos para lidar com transientes de cargas indutivas e curtos-circuitos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibilidade com IOP em todo o sistema:\u003c\/strong\u003e Totalmente compatível com processadores de saída digital Honeywell PM, APM, HPM e EHPM em trechos de cabo padrão de 50 metros.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuporte manual em espera:\u003c\/strong\u003e Permite a conexão a unidades externas de operação manual em espera, possibilitando substituições manuais das saídas e manutenção contínua sem desenergizar as cargas de campo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpção de revestimento isolante:\u003c\/strong\u003e Disponível com opções de proteção ambiental reforçada para instalação em atmosferas industriais corrosivas severas ISA G3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProjeto de terminal industrial:\u003c\/strong\u003e Oferece opções de terminais de compressão ou de parafuso para serviços pesados, compatíveis com fiação de campo de até 14 AWG, simplificando a instalação.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComutação de elementos finais de controle:\u003c\/strong\u003e Controle piloto direto de partidas de motores de 120\/240 VCA, contatores e circuitos de permissão de partida\/parada de inversores de velocidade variável.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControle de válvulas solenoides:\u003c\/strong\u003e Acionamento de alta confiabilidade de válvulas solenoides pneumáticas e hidráulicas para serviços pesados em unidades de processo de óleo, gás e produtos químicos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface de alarmes e anunciadores:\u003c\/strong\u003e Aciona sirenes de campo de alta potência, sinalizadores visuais, painéis de luzes indicadoras e relés mestres de intertravamento de segurança.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolamento e expansão do DCS:\u003c\/strong\u003e Fornece sinais de interface de contato seco entre as redes de automação TPS da Honeywell e equipamentos de terceiros ou CLPs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFabricante\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero do modelo\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero da peça\/conjunto\u003c\/td\u003e\n\u003ctd\u003e51309150-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de produto\u003c\/td\u003e\n\u003ctd\u003eConjunto de terminação de campo do relé de saída digital (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibilidade do sistema\u003c\/td\u003e\n\u003ctd\u003eHoneywell TPS (PM, APM, HPM, EHPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanais de saída\u003c\/td\u003e\n\u003ctd\u003e16 canais discretos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão nominal de campo\u003c\/td\u003e\n\u003ctd\u003e240 VCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolamento entre campo e sistema\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS ou ±1500 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTécnica de isolamento\u003c\/td\u003e\n\u003ctd\u003eIsolamento galvânico \/ óptico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistância do cabo de interface\u003c\/td\u003e\n\u003ctd\u003eAté 50 metros até o IOP de Saídas Digitais\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBitola do fio de campo\u003c\/td\u003e\n\u003ctd\u003eTerminais de compressão \/ parafuso para fios de até 14 AWG (~1,6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura operacional\u003c\/td\u003e\n\u003ctd\u003e0 a 50 °C (temperatura ambiente do gabinete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de armazenamento\u003c\/td\u003e\n\u003ctd\u003e-40 a 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidade operacional\u003c\/td\u003e\n\u003ctd\u003e10 a 90%, sem condensação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbiente padrão\u003c\/td\u003e\n\u003ctd\u003eISA G1 (Moderado) \/ opção ISA G3 (Severo) disponível\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Conector\u003c\/th\u003e\n\u003cth\u003eFunção\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConector do cabo do IOP\u003c\/td\u003e\n\u003ctd\u003eAceita cabo multip condutor Honeywell padrão para conexão direta ao IOP de Saídas Digitais (até 50 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlocos de terminais de campo\u003c\/td\u003e\n\u003ctd\u003eTerminais de compressão ou de parafuso reforçados para fiação de campo direta de 16 canais e conexões de carga de relés\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConector manual de espera\u003c\/td\u003e\n\u003ctd\u003ePorta de interface para conexão da Unidade opcional Honeywell de Substituição Manual em Espera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de instalação\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspeção pré-instalação:\u003c\/strong\u003e Verifique o número da peça da placa (MU-TDOR22 \/ 51309150-125) e procure danos físicos antes da montagem dentro do gabinete.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontagem:\u003c\/strong\u003e Trave firmemente o Conjunto de Terminação de Campo no canal de montagem FTA padrão dentro do gabinete ou invólucro Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupção da alimentação:\u003c\/strong\u003e Certifique-se de que a alimentação da carga no lado de campo e a alimentação do gabinete estejam desconectadas antes de conectar a fiação, para evitar riscos de choque elétrico ou arco elétrico.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação da fiação:\u003c\/strong\u003e Desencape adequadamente os condutores de campo e conecte os circuitos de carga de 240 VCA aos terminais correspondentes dos canais, usando fios de até 14 AWG e verificando se as conexões mecânicas estão firmes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConexão do cabo do IOP:\u003c\/strong\u003e Conecte o cabo de E\/S Honeywell pré-fabricado entre o conector da placa FTA e o slot atribuído ao Processador de Saídas Digitais no bastidor de cartões.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAterramento:\u003c\/strong\u003e Verifique se o aterramento de proteção do gabinete e os aterramentos das blindagens estão continuamente equipotencializados de acordo com as diretrizes de instalação do sistema Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificações de comissionamento:\u003c\/strong\u003e Realize verificações de continuidade da fiação ponto a ponto, verifique a integridade dos fusíveis e aplique a alimentação da carga antes de colocar o IOP associado em operação.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667753136491,"sku":"MU-TDOR22 51309150-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s-l1600_1200x1200_ca6723cc-cded-48bb-b2f0-41cb5db3ddfd.webp?v=1787713068","url":"https:\/\/www.plcprotech.com\/pt\/products\/honeywell-mu-tdor22-51309150-125-digital-output-relay-field-termination-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}