{"product_id":"honeywell-tc-ioli01-51403427-125-plantscape-experion-c200-i-o-link-interface-module","title":"Módulo de interface de link de E\/S Honeywell TC-IOLI01 51403427-125 PlantScape Experion C200","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003eHoneywell TC-IOLI01\u003c\/strong\u003e (Número de peça \u003cstrong\u003e51403427-125\u003c\/strong\u003e) é um Módulo de Interface I\/O Link (I\/O LIM) projetado para integração à arquitetura de controle de processos \u003cstrong\u003eHoneywell PlantScape\u003c\/strong\u003e e \u003cstrong\u003eExperion PKS C200\u003c\/strong\u003e. Ele atua como um módulo dedicado de interface de link de comunicação, estabelecendo a transferência determinística de dados entre o backplane do chassi do Processador de Controle C200 e os racks de chassis de E\/S distribuídos ou as redes de terminação de E\/S de campo por meio do barramento de E\/S Link dedicado.\u003c\/p\u003e\n\u003cp\u003eComo unidade central de comunicação na infraestrutura do controlador C200, o \u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e gerencia a varredura de E\/S em tempo real, o buffer de sinais e a troca de dados em alta velocidade para garantir um desempenho consistente e de baixa latência dos loops de controle. O módulo roteia a alimentação CC de múltiplos trilhos diretamente do backplane para alimentar a lógica de comunicação interna e os circuitos transceptores de linha.\u003c\/p\u003e\n\u003cp\u003eDesenvolvido para ambientes industriais de processos severos, o hardware conta com proteção integrada, certificações de órgãos reguladores de múltiplas jurisdições para locais perigosos classificados e compatibilidade com a montagem padrão em chassis. O módulo permite a expansão contínua do sistema, possibilitando que engenheiros de processos integrem subsistemas de E\/S locais e remotos em uma única rede de controle unificada.\u003c\/p\u003e\n\u003ch3\u003eRecursos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface de barramento de E\/S dedicada:\u003c\/strong\u003e Facilita a comunicação de alta velocidade entre o Processador de Controle Experion C200 e os racks de E\/S conectados pela rede Honeywell I\/O Link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoteamento determinístico de sinais:\u003c\/strong\u003e Fornece varredura de E\/S em tempo real e transferência de dados com baixa variação temporal para loops de processo críticos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlimentação por múltiplos trilhos do backplane:\u003c\/strong\u003e Utiliza os trilhos internos de alimentação do backplane (1,2 VCC, 3,3 VCC, 5,1 VCC e 24 VCC) para processamento interno e interfaces de comunicação.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformidade com ambientes industriais:\u003c\/strong\u003e Certificado para locais perigosos Classe I, Divisão 2 (Grupos A, B, C, D com código de temperatura T4A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign integrado ao chassi:\u003c\/strong\u003e Formato padrão de montagem em slot, desenvolvido para instalação em racks de chassis de controle C200.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSistemas PlantScape e Experion PKS C200:\u003c\/strong\u003e Interconecta controladores C200 a chassis de E\/S distribuídos e conjuntos de terminação de campo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControle distribuído de processos:\u003c\/strong\u003e Estabelece links de comunicação de E\/S de alta velocidade entre gabinetes de controle de processos em instalações químicas, de refino e de manufatura.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMigração de rede de controle legada:\u003c\/strong\u003e Atua como uma ponte de comunicação essencial para expandir ou manter racks de controle Honeywell C200 existentes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações técnicas\u003c\/h3\u003e\n\u003ch4\u003eGeral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFabricante\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero do modelo\u003c\/td\u003e\n\u003ctd\u003eTC-IOLI01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de peça do OEM\u003c\/td\u003e\n\u003ctd\u003e51403427-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevisão\u003c\/td\u003e\n\u003ctd\u003eRevisão de hardware A \/ Revisão de firmware A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de produto\u003c\/td\u003e\n\u003ctd\u003eMódulo de interface do I\/O Link (I\/O LIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlataforma do sistema de destino\u003c\/td\u003e\n\u003ctd\u003eHoneywell PlantScape \/ Experion PKS C200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaís de origem\u003c\/td\u003e\n\u003ctd\u003eEUA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEspecificações elétricas\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eConsumo de corrente\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntrada do backplane a 1,2 VCC\u003c\/td\u003e\n\u003ctd\u003e0,004 A (4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntrada do backplane a 3,3 VCC\u003c\/td\u003e\n\u003ctd\u003e0,31 A (310 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntrada do backplane a 5,1 VCC\u003c\/td\u003e\n\u003ctd\u003e0,4 A (400 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntrada do backplane a 24 VCC\u003c\/td\u003e\n\u003ctd\u003e0,073 A (73 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de instalação\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação pré-instalação:\u003c\/strong\u003e Confirme se o número de peça do módulo (\u003cstrong\u003e51403427-125\u003c\/strong\u003e) corresponde aos desenhos do sistema. Inspecione os conectores de borda do backplane quanto a danos ou contaminação antes da inserção.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolamento da alimentação:\u003c\/strong\u003e Certifique-se de que a fonte de alimentação do chassi C200 de destino esteja completamente desenergizada antes de inserir ou remover o módulo, para evitar transientes elétricos ou interrupções no barramento do backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontagem no chassi:\u003c\/strong\u003e Alinhe as bordas da placa do módulo às guias do slot do chassi. Deslize o módulo firmemente para dentro do slot até que o conector do backplane esteja totalmente encaixado e, em seguida, aperte os parafusos de retenção do chassi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabeamento do I\/O Link:\u003c\/strong\u003e Conecte os cabos coaxiais ou twinaxiais aprovados pela Honeywell aos conectores do módulo. Certifique-se de que os cabos tenham alívio de tensão e que resistores adequados de terminação de linha estejam instalados em ambas as extremidades do segmento.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAterramento e blindagem:\u003c\/strong\u003e Mantenha conexões de aterramento limpas no gabinete. Certifique-se de que as blindagens dos cabos coaxiais estejam conectadas de acordo com as diretrizes da publicação técnica TC-DCSX21 da Honeywell para reduzir interferências EMI\/RFI.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eComissionamento e substituição\u003c\/h3\u003e\n\u003ch3\u003eRecomendações de comissionamento\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerificação da tensão de alimentação:\u003c\/strong\u003e Verifique se as tensões do backplane do chassi (+1,2 VCC, +3,3 VCC, +5,1 VCC, +24 VCC) estão dentro dos limites nominais antes de inicializar os loops de comunicação.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnóstico do link:\u003c\/strong\u003e Monitore os registros de status do sistema do controlador para verificar se o LIM de E\/S é reconhecido na rede I\/O Link sem relatar erros de quadro ou sinalizadores de novas tentativas no barramento.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConsiderações sobre a substituição\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup de parâmetros:\u003c\/strong\u003e Faça backup dos dados de configuração do sistema no Experion Builder antes de substituir um módulo de interface ativo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibilidade do firmware:\u003c\/strong\u003e Certifique-se de que o hardware e a revisão do firmware do módulo de substituição correspondam à configuração do sistema de destino (Rev. A do firmware) para manter temporização previsível de E\/S e comportamento previsível da rede.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConformidade e certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eListado pela UL:\u003c\/strong\u003e Equipamento de controle industrial 48RL (Listado pela UL)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificado pela CSA:\u003c\/strong\u003e Certificado para locais perigosos\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAprovado pela FM:\u003c\/strong\u003e Aprovado pela Factory Mutual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarca CE:\u003c\/strong\u003e Conformidade Europeia\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM \/ C-Tick:\u003c\/strong\u003e N314\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClassificação para locais perigosos:\u003c\/strong\u003e Classe I, Divisão 2, Grupos A, B, C, D; Código de temperatura T4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentação de referência:\u003c\/strong\u003e Publicação técnica TC-DCSX21\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668012003691,"sku":"TC-IOLI01 51403427-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-IOLI01-51403427-125_003_1200x1200_04003502-f3b3-4e04-b08e-0bea5fa2725b.jpg?v=1786961241","url":"https:\/\/www.plcprotech.com\/pt\/products\/honeywell-tc-ioli01-51403427-125-plantscape-experion-c200-i-o-link-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}