{"product_id":"ics-triplex-t8111-trusted-tmr-processor-module","title":"Módulo Processador Confiável TMR ICS Triplex T8111","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eICS Triplex T8111\u003c\/strong\u003e é um componente principal de processamento tolerante a falhas projetado para a arquitetura do sistema \u003cstrong\u003eTrusted\u003c\/strong\u003e. Operando em uma configuração Triple Modular Redundant (TMR) lock-step através de três regiões independentes de contenção de falhas do processador (FCRs), o \u003cstrong\u003eT8111\u003c\/strong\u003e executa programas de aplicação definidos pelo usuário, realiza monitoramento do sistema e gerencia trocas de dados de E\/S através do barramento inter-módulos triplicado. O módulo integra duas portas seriais configuráveis RS422\/485, uma porta serial RS485 de 2 fios dedicada, uma interface de diagnóstico RS232 no painel frontal e capacidades integradas de sincronização de tempo IRIG-B. O \u003cstrong\u003eICS Triplex T8111\u003c\/strong\u003e é projetado para funções instrumentadas de segurança críticas e aplicações de controle de processo que exigem alta disponibilidade e isolamento de falhas.\u003c\/p\u003e\n\u003ch3\u003eCaracterísticas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eArquitetura Triple Modular Redundant (TMR) com relógio e mecânica de votação tolerante a falhas implementados em hardware (HIFT).\u003c\/li\u003e\n\u003cli\u003eTrês processadores da série NXP PowerQUICC II executando lógica de aplicação em sincronização lock-step.\u003c\/li\u003e\n\u003cli\u003eSuporte para substituição a quente em configurações de slot companheiro ativo\/em espera sem recarregamento do programa.\u003c\/li\u003e\n\u003cli\u003eEntradas integradas de sincronização de tempo IRIG-B002 (RS422\/485) e IRIG-B122 (modulado a 1 kHz).\u003c\/li\u003e\n\u003cli\u003ePorta serial de diagnóstico RS232 no painel frontal e indicadores LED de status\/diagnóstico.\u003c\/li\u003e\n\u003cli\u003eSaídas de contato de relé de falha e falha do processador ativo e em espera.\u003c\/li\u003e\n\u003cli\u003eSuporte à linguagem de programação IEC 61131-3 via o conjunto de ferramentas do sistema.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSistemas Instrumentados de Segurança (SIS)\u003c\/li\u003e\n\u003cli\u003eSistemas de Desligamento de Emergência (ESD)\u003c\/li\u003e\n\u003cli\u003eSistemas de Detecção de Incêndio e Gás (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eSistemas Críticos de Controle de Processo\u003c\/li\u003e\n\u003cli\u003eSistemas de Gerenciamento de Queimadores (BMS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICS Triplex \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlimentação do Backplane (IMB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Vcc a 32 Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDissipação de Energia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocalização do Módulo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlot do Processador T8100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePortas de Comunicação Serial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Portas Seriais Traseiras (RS-422\/485), 1 Porta Serial de Diagnóstico (RS-232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePortas de Sincronização de Tempo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 IRIG-B002, 1 IRIG-B122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSaídas de Relé\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Relé de Falha (0,5 A @ 24 Vcc), 1 Relé de Falha (0,5 A @ 24 Vcc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTaxas de Baud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9600 baud a 115200 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocolos de Comunicação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (via Portas Seriais Traseiras)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTamanho Máximo da Aplicação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmazenamento de Variáveis Retidas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 KB total (1 byte por Booleano, 4 bytes por Analógico, 5 bytes por Temporizador)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer SOE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 eventos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C a 60 °C (32 °F a 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura de Armazenamento\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 °C a 70 °C (-13 °F a 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidade Relativa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%-95%, sem condensação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e266 mm x 93 mm x 303 mm (10,5 pol x 3,6 pol x 12,0 pol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,89 kg (4,17 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePino do Conector\u003c\/th\u003e\n\u003cth\u003eFunção\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pino 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelé de Falha (NF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pino 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelé de Falha (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pino 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelé de Falha (NA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pinos 22, 24, 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerra do Chassi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pino 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 3 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pino 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 3 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha A Pino 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRetorno 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Porta 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 1 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Porta 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 2 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 2 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 2 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 2 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Porta 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 3 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorta Serial 3 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAviso de Baixa Tensão da PSU 1 de 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAviso de Baixa Tensão da PSU 2 de 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha C Pino 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRetorno 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelé de Falha (NF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelé de Falha (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelé de Falha (NA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pinos 22, 24, 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerra do Chassi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFalha de Desligamento da PSU 1 de 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFalha de Desligamento da PSU 2 de 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Linha E Pino 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRetorno 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspeção Visual: Inspecione a carcaça do módulo e os conectores traseiros de E\/S para verificar pinos danificados ou dobrados antes da instalação. Não tente endireitar pinos dobrados.\u003c\/li\u003e\n\u003cli\u003eSegurança contra Descarga Eletrostática: Devem ser observadas precauções para manuseio estático. Não toque nos pinos expostos do conector nem tente abrir a carcaça do módulo.\u003c\/li\u003e\n\u003cli\u003eProcedimento de Inserção: Certifique-se de que a unidade adaptadora traseira está instalada. Libere totalmente as abas ejetoras superior e inferior usando a chave de liberação, deslize o módulo suavemente para o slot designado no chassi e pressione a fachada até que os ejetores travem com um clique.\u003c\/li\u003e\n\u003cli\u003ePosições da Chave Principal: Ajuste a chave de habilitação de manutenção para 'Run' para bloquear a memória durante a execução padrão, ou para 'Maintain' para permitir downloads de aplicação a partir da estação de trabalho.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformidade e Certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCertificado conforme IEC 61508 SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53618505908587,"sku":"T8111","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/T8311_1_afe40af2-d7e1-41cb-b5c8-a0d20d40879d.jpg?v=1785229424","url":"https:\/\/www.plcprotech.com\/pt\/products\/ics-triplex-t8111-trusted-tmr-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}