{"product_id":"inici03-abb-infi-net-to-infi-net-local-transfer-mod","title":"Módulo de Transferência Local INICI03 ABB Infi-Net para Infi-Net","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO Módulo de Transferência Local Infi-Net para Infi-Net \u003cstrong\u003eINICI03\u003c\/strong\u003e é uma interface de comunicação para rack Harmony projetada para o Sistema de Gerenciamento e Controle Symphony Enterprise. Serve como uma ponte inteligente, fornecendo a um computador host ou Interface Homem-Máquina (HSI) acesso direto à Rede de Controle (\u003cstrong\u003eCnet\u003c\/strong\u003e) ou ao sistema de comunicação \u003cstrong\u003eINFI-NET\u003c\/strong\u003e.  \u003c\/p\u003e\n\n\u003cp\u003eO \u003cstrong\u003eINICI03\u003c\/strong\u003e é compatível com versões anteriores dos Sistemas de Gerenciamento Estratégico Empresarial \u003cstrong\u003eINFI 90 OPEN\u003c\/strong\u003e.  \u003c\/p\u003e\n\n\u003cp\u003eO conjunto completo de interface é um sistema de hardware multimódulo composto por três componentes principais:  \u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de Interface de Rede INNIS01:\u003c\/strong\u003e Fornece a conexão inteligente de front-end entre o nó e a rede de comunicação.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de Transferência de Computador INICT03:\u003c\/strong\u003e Atua como o núcleo de processamento comandado para armazenamento de dados, tabelas de pontos e interações com o host.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo Interface de Processador Multifuncional IMMPI01:\u003c\/strong\u003e Fornece a interface física de hardware para conexões host seriais RS-232-C ou paralelas SCSI.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCaracterísticas  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmazenamento de Dados de Alta Capacidade:\u003c\/strong\u003e Organiza e compacta dinamicamente informações de processo e relatórios de exceção para transmissão eficiente na rede.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrande Capacidade de Armazenamento de Pontos:\u003c\/strong\u003e O módulo integrado \u003cstrong\u003eINICT03\u003c\/strong\u003e pode armazenar até 30.000 definições de pontos, dependendo dos tipos de pontos.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegridade Robusta dos Dados:\u003c\/strong\u003e Os quadros de rede transmitidos utilizam códigos de Verificação de Redundância Cíclica (CRC) e verificação de soma de verificação.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecuperação Automática de Energia:\u003c\/strong\u003e Procedimentos localizados de inicialização e desligamento são executados automaticamente após uma falha de energia.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessamento Assíncrono:\u003c\/strong\u003e O armazenamento local de dados permite que o computador host consulte os dados independentemente do relógio em tempo real \u003cstrong\u003eCnet\u003c\/strong\u003e.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAplicações  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSistemas de Gerenciamento e Controle Symphony Enterprise  \u003c\/li\u003e\n\u003cli\u003eIntegração do sistema INFI 90 OPEN DCS  \u003c\/li\u003e\n\u003cli\u003eEstações centrais de engenharia e configuração usando ferramentas Composer  \u003c\/li\u003e\n\u003cli\u003eEstações de trabalho de Interface Homem-Máquina em toda a planta usando Conductor NT ou Conductor VMS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePropriedade\u003c\/th\u003e\n\u003cth\u003eCaracterística \/ Valor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ Bailey Hartmann \u0026amp; Braun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID do Produto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINIIT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo de Produto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePaís de Origem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eItália (IT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEstocado em\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eITABB004EXPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantidade Mínima de Pedido\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 peça\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisitos de Energia IMMPI01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC a 415 mA; 2,08 W típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemória INICT03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 kbytes ROM; 2 Mbytes RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisitos de Energia INICT03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC a 1,958 A; 9,8 W típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTaxas de Comunicação INICT03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 a 19.200 baud via RS-232-C; 4 Mbytes\/seg via SCSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemória INNIS01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 kbytes ROM; 208 kbytes RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisitos de Energia INNIS01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC a 900 mA (4,5 W típico); +15 VDC a 5 mA (0,08 W típico); -15 VDC a 200 mA (3 W típico)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTaxas de Rede INNIS01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mbaud ou 2 Mbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacidade do Sistema\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAté 62.500 nós totais do sistema; até 250 nós por loop individual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMontagem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCada módulo ocupa um slot em uma Unidade de Montagem de Módulos (MMU) padrão\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura Ambiente\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 a 70°C (32 a 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidade Relativa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% a 90% até 55°C (131°F), sem condensação; 5% a 40% acima de 55°C (131°F), sem condensação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressão Atmosférica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNível do mar até 3 km (1,86 mi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQualidade do Ar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNão corrosivo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção Eletrostática:\u003c\/strong\u003e Os módulos contêm componentes sensíveis à descarga eletrostática. O pessoal deve usar uma pulseira aterrada conectada ao terra do chassi do gabinete antes de manusear a circuitaria.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguração do Endereço de Hardware:\u003c\/strong\u003e Antes de instalar os módulos na Unidade de Montagem de Módulos, configure os interruptores DIP da placa de circuito para o endereço de nó, endereço do loop e modo de operação do loop necessários.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemporizador de Falha da Máquina:\u003c\/strong\u003e Não opere os módulos com o circuito do temporizador de falha da máquina manualmente desativado. Isso pode produzir sequências de saída imprevisíveis e comprometer a segurança do loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInserção do Módulo:\u003c\/strong\u003e Verifique os limites de carga de energia do gabinete antes da instalação. Insira cada módulo em seu slot designado no card-cage e aperte completamente ambos os parafusos de fixação da placa frontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668623913323,"sku":"INIIT03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-iniit03-infi-90-infi-net-to-infi-net-transfer-module-1etrqjpqswv_54d4e216-f412-479b-9f7b-897eccce6bc3.jpg?v=1765535906","url":"https:\/\/www.plcprotech.com\/pt\/products\/inici03-abb-infi-net-to-infi-net-local-transfer-mod","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}