{"product_id":"is220ppros1b-general-electric-mark-vie-backup-turbine-protection-i-o-module","title":"Módulo I\/O de Proteção de Turbina Backup GE General Electric Mark VIe IS220PPROS1B","description":"\u003ch3\u003eSubsistema do Sistema e Valor Operacional Crítico\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PPROS1B (IS220PPROS1B)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um módulo de E\/S de proteção de turbina de backup de alta confiabilidade e segurança crítica, projetado para a plataforma de controle General Electric Mark VIe. Este bloco de processamento distribuído se conecta diretamente a placas terminais dedicadas para executar funções independentes de disparo de emergência baseadas em hardware, detecção mecânica de sobrerotação e sub-rotinas de desaceleração de emergência. Operando em setores de utilidades de alto risco — como grandes usinas termelétricas, instalações de geração nuclear e complexos petroquímicos de craqueamento de gás — o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PPROS1B (IS220PPROS1B)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efornece uma camada autônoma de proteção separada dos processadores de controle primários. Mantendo uma estrutura local de roteamento redundante modular tripla (TMR) em suas placas terminais, o módulo monitora simultaneamente sensores críticos de velocidade e intertravamentos de disparo. Essa lógica de ação rápida garante disparos instantâneos da turbina durante condições perigosas de sobrerotação, protegendo ativos rotativos de milhões de dólares e eliminando paradas operacionais inesperadas.\u003c\/p\u003e\n\u003ch3\u003eArquitetura de Segurança de Hardware e Interface com Terminais\u003c\/h3\u003e\n\u003cp\u003eO design físico e eletrônico do módulo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efoca no monitoramento de segurança tolerante a falhas e na conformidade industrial robusta.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmparelhamento Abrangente de Placas Terminais:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProjetado para montagem direta em placas terminais acessórias especializadas, suportando configurações compactas simplex e blocos completos de configuração TMR, incluindo as séries SPRO, TPRO e TREA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConectividade Ethernet Dupla:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncorpora duas portas IONet para fornecer comunicações Ethernet redundantes e determinísticas, transmitindo sinais de diagnóstico para a rede de controle supervisório Mark VIe sem interromper os circuitos locais de segurança.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertificação para Áreas Perigosas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConstruído para suportar implantações operacionais severas, com classificações globais à prova de chama Classe I, Divisão 2 e ATEX Zona 2, permitindo posicionamento seguro mais próximo ao invólucro físico da turbina.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParâmetros Mecânicos, Térmicos e de Conformidade\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategoria do Parâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação Técnica Detalhada\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNúmero do Modelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220PPROS1B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE \/ Série Mark VIe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunção do Módulo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcessador de E\/S para Proteção de Turbina de Backup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlacas Terminais Compatíveis\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200SPROH1A, IS200SPROH2A, IS200TPROH1C, IS200TPROH2C, IS200TPROS1C, IS200TPROS2C, IS200TREAH1A, IS200TREAH3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 a +65 °C (-22 a +149 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,5 W Típico (Fornecido por duas linhas de entrada de 28 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClasse para Locais Perigosos\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClasse I, Divisão 2, Grupos A, B, C, D, T4 \/ Zona 2, Grupo IIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNormas de Classificação ATEX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEx nA IIC T4 Gc (ULDEMKO13ATEX1214780X)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eListagens Gerais de Segurança\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL508 Ed.17, CSA-C22.2 No.142-M1987, ANSI\/ISA-12.12.01-2015\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNormas para Atmosferas Explosivas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL60079-15 Ed.3, EN60079-0:2012, EN60079-15:2010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso Estimado da Embalagem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePaís de Origem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEstados Unidos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Serviço de Campo\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual placa terminal acessória deve ser selecionada para interface padrão com relé de disparo de emergência?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA escolha depende da sua arquitetura. Para sistemas típicos de proteção de relé de disparo de emergência de turbina, o módulo é emparelhado com as placas IS200TPRO ou IS200TREA. A placa TPRO se conecta diretamente a captadores magnéticos passivos de velocidade e gerencia contatos de desaceleração de emergência, enquanto a TREA fornece caminhos especializados de execução de disparo para solenoides da linha de lubrificação e hidráulica da turbina.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuais ações devem ser tomadas se um alarme térmico da Zona 2 ATEX for acionado?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerifique se a temperatura ambiente ao redor do invólucro do módulo não ultrapassou o limite máximo rigoroso de +65 °C. Certifique-se de que os ventiladores internos do gabinete estejam funcionando, que as aberturas de fluxo convectivo estejam desobstruídas e que os componentes próximos que irradiam calor mantenham distância estrutural adequada.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo é gerenciada a sincronização do firmware ao substituir um módulo antigo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO sistema Mark VIe suporta download automático de parâmetros. Quando um módulo Original Novo IS220PPROS1B é instalado na placa terminal ativa e conectado à rede IONet, o controlador mestre identifica o endereço de hardware do dispositivo e automaticamente envia a revisão de firmware designada e os parâmetros do perfil de segurança para a placa.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcoplamento Mecânico da Placa Terminal:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAo unir o módulo IS220PPROS1B à sua placa terminal associada, alinhe cuidadosamente os pinos-guia plásticos antes de encaixar os conectores d-sub de alta densidade. Aperte os parafusos de fixação integrados com torque padrão de 1,2 Nm. Parafusos soltos comprometem a fixação estrutural, causando referências de terra intermitentes e alarmes de disparo indesejados sob alta vibração da turbina.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegridade da Blindagem e Aterramento de Alta Frequência:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTodos os cabos de captadores passivos de velocidade e sensores de velocidade que entram nos terminais das placas TPRO ou SPRO devem usar blindagem trançada individual de alta densidade. Conecte a blindagem do cabo somente no ponto de barra de terra da placa terminal. Aterramento incorreto em ambas as extremidades da blindagem cria loops de terra estruturais, injetando interferência eletromagnética que pode causar leituras falsas de sobrerotação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento do Invólucro Ambiental para Áreas Explosivas:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePara manter a validade das certificações sem ferramentas ANSI\/ISA-12.12.01-2015 e EN60079-15, este módulo de E\/S deve estar totalmente alojado dentro de um invólucro industrial com proteção IP54 ou superior, fixado por ferramentas. Essa medida protege as conexões do circuito contra corrosivos químicos no ar, acúmulo pesado de poeira e níveis de umidade que excedam os limites sem condensação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695408378219,"sku":"IS220PPROS1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220ppros1b-emergency-turbine-protection-i-o-pack-zi3byazo4zb_f4b941c4-25b6-4fbc-9823-079ec4c9dce8.jpg?v=1766134968","url":"https:\/\/www.plcprotech.com\/pt\/products\/is220ppros1b-general-electric-mark-vie-backup-turbine-protection-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}