{"product_id":"kj3222x1-ba3-emerson-deltav-ai-8-ch-4-20ma-hart-series-2-i-o-card","title":"KJ3222X1-BA3 Emerson DeltaV Cartão de E\/S Série 2 AI 8-CH 4-20mA HART","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eA \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3222X1-BA3 (KJ3222X1BA3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma placa de entrada analógica de alta densidade com 8 canais, projetada para os sistemas de automação digital DeltaV S-series e Series 2. Desenvolvida para controle de processos críticos em indústrias como refino químico, geração de energia e fabricação farmacêutica, esta placa facilita a integração perfeita de dispositivos de campo 4-20 mA com comunicação digital HART (Highway Addressable Remote Transducer) integrada. Ao fornecer acesso em tempo real a dados de variáveis secundárias e diagnósticos de saúde dos instrumentos, a KJ3222X1-BA3 possibilita estratégias de manutenção preditiva e otimiza o desempenho do loop. Sua arquitetura robusta garante aquisição contínua de dados enquanto protege o controlador contra transientes elétricos do lado do campo, minimizando paradas não planejadas e aumentando a segurança geral da planta.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhes)\u003c\/h3\u003e\n\u003cp\u003eA placa de Entrada Analógica Series 2 utiliza condicionamento avançado de sinal e comunicação de barramento de alta velocidade para manter a transferência de dados com alta fidelidade.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacidade de Passagem HART:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA placa possui modems internos dedicados para cada um dos 8 canais, permitindo que o sistema DeltaV leia simultaneamente a variável primária 4-20 mA e se comunique digitalmente com instrumentos de campo \"inteligentes\" para configuração e solução de problemas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesign com Limitação de Energia:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertificada para uso em atmosferas perigosas, a placa suporta instalação em ambientes Zona 2 \/ Divisão 2. Incorpora circuitos limitadores de corrente para garantir a integridade do loop de E\/S em nós com limitação de energia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuporte a Redundância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo é projetado para uso em pares redundantes. Quando instalado em um bloco\/carrier terminal redundante, o sistema fornece comutação automática sem interrupção, garantindo que a falha de uma única placa não interrompa o monitoramento crítico do processo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSistema de Chaveamento Rotativo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara evitar instalação incorreta do hardware, a placa utiliza um sistema mecânico de chaveamento rotativo que assegura a compatibilidade entre a placa de E\/S e seu bloco terminal específico.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ3222X1-BA3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (DeltaV)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEUA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNúmero de Peça Alternativo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12P2532X092\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNúmero de Canais\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSinal de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlimentação do Barramento Local\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC a 150 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlimentação do Campo no Barramento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC a 300 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura Ambiente\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 a +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertificação para Áreas Perigosas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx Zona 2; Classe 1 Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eP1: Qual a diferença entre a versão BA3 e a série BA1 mais antiga?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR1: As placas Series 2 (BA3) oferecem maior resistência ambiental e perfis de certificação atualizados (ATEX\/UKEX). Embora mantenham compatibilidade retroativa na maioria dos ambientes DeltaV, são otimizadas para as revisões mais recentes do hardware S-series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP2: Esta placa requer calibração manual no campo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR2: Não, a KJ3222X1-BA3 não possui partes ou pontos de ajuste que possam ser reparados pelo usuário. A unidade é calibrada de fábrica para alta precisão e mantém sua exatidão durante toda a vida útil sem intervenção manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP3: Posso remover esta placa com o sistema energizado?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR3: A alimentação de campo deve ser removida do bloco terminal ou carrier antes de conectar ou desconectar o dispositivo. Sempre consulte o documento 12P2046 sobre instruções de instalação em Zona 2 para procedimentos seguros de remoção e inserção.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibilidade do Bloco Terminal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertifique-se de que as chaves rotativas no bloco terminal estejam na posição A1 antes de tentar encaixar a placa. Forçar a placa em um bloco com chaveamento incorreto danificará os pinos do conector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvaliação do Loop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara instalações em áreas perigosas, deve ser realizada uma avaliação do loop de E\/S em todos os nós com limitação de energia para verificar se os parâmetros combinados da placa, cabo e dispositivo de campo cumprem as certificações de segurança.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção contra Contaminantes Atmosféricos:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA placa é classificada para ambientes ISA-S71.04-1985 Classe G3. No entanto, para máxima durabilidade em atmosferas corrosivas, mantenha os sistemas de resfriamento e filtragem do gabinete DeltaV para evitar acúmulo de poeira condutiva.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eA KJ3222X1-BA3 destaca-se por sua ampla faixa de operação em temperatura extrema (-40 a +70 °C), permitindo instalação em invólucros remotos de instrumentos sem necessidade de controle climático ativo em muitas regiões. Seu modem HART integrado de 8 canais reduz significativamente a complexidade do hardware em comparação com sistemas legados que exigiam multiplexadores externos. Essa integração permite que os engenheiros da planta utilizem todo o potencial do AMS Device Manager diretamente da estação de trabalho DeltaV, facilitando a análise remota da assinatura de válvulas e o ajuste de transmissores sem enviar técnicos ao campo.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695424041323,"sku":"KJ3222X1-BA1 12P2532X092","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/KJ3222X1-BA3.png?v=1775913658","url":"https:\/\/www.plcprotech.com\/pt\/products\/kj3222x1-ba3-emerson-deltav-ai-8-ch-4-20ma-hart-series-2-i-o-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}