{"product_id":"lenze-evs9324-epv004-9300-series-servo-position-controller","title":"Lenze EVS9324-EPV004 9300 Series Servo Position Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Designed for high-precision motion control, the \u003cstrong\u003eLenze EVS9324-EPV004\u003c\/strong\u003e serves as a robust servo position controller within the 9300 Series architecture. This \u003cstrong\u003e3.0 kW\u003c\/strong\u003e rated unit provides closed-loop positioning and speed control for demanding industrial automation environments. Featuring an \u003cstrong\u003eIP20\u003c\/strong\u003e protection rating, it is engineered for direct installation inside electrical control cabinets, offering reliable performance and seamless integration with legacy fieldbus networks.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eIntegrated position controller with configurable motion profiles and homing routines.\u003c\/li\u003e\n  \u003cli\u003eRobust IP20 degree of protection, optimized for space-saving control cabinet mounting.\u003c\/li\u003e\n  \u003cli\u003eHigh-performance resolver feedback interface for precise closed-loop control.\u003c\/li\u003e\n  \u003cli\u003eFlexible system bus communication capabilities for multi-axis synchronization.\u003c\/li\u003e\n  \u003cli\u003eThermal monitoring and overload protection to safeguard the drive and motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e High-speed indexing, wrapping, and cartoning systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Gantry systems, automated storage\/retrieval systems (ASRS), and transfer carriages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTextile Manufacturing:\u003c\/strong\u003e Precise winding, tension control, and feed-axis synchronization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrinting and Paper Processing:\u003c\/strong\u003e Rotary cut-offs, cross-cutters, and web-guiding systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEVS9324-EPV004\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9300 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eServo Position Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out \/ Legacy Spare Part\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e35.00 x 25.00 x 9.70 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTerminal \/ Connector\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eControl Terminals (Digital Inputs\/Outputs, Analog Inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eResolver Input (Feedback loop connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem Bus (CAN interface for multi-drive networking)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eX6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEncoder Output \/ Encoder Simulation\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The EVS9324-EPV004 is a dedicated positioning controller (\"EP\" variant) and cannot be directly swapped with standard speed controllers (\"ES\" variants) without modifying the system PLC program and drive parameter sets. When replacing older hardware revisions, ensure that the firmware version of the replacement unit matches or is backward-compatible with your existing system configuration. Parameter transfers should be executed using Lenze Global Drive Control (GDC) software.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To ensure reliable operation, thermal management within the enclosure is critical. When mounting multiple 9300 Series drives side-by-side, maintain a minimum lateral clearance of 10 mm and a vertical clearance of at least 100 mm to facilitate natural convection. High-inertia applications requiring rapid deceleration must be paired with an appropriately sized external braking resistor connected to terminals UG+ and BR to prevent Overvoltage (OU) faults on the DC bus.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always use double-shielded twisted-pair cabling for the resolver feedback (X2) and system bus (X5) to mitigate electromagnetic interference (EMI). The cable shields must be grounded at both ends using low-impedance EMC shield clamps directly on the mounting plate. Before applying main 3-phase AC power, verify that the auxiliary 24 VDC control supply is stable and correctly wired to ensure the control board initializes properly.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Hazardous voltage may be present on the power terminals for up to 5 minutes after disconnecting the AC supply. Always verify that the DC-bus voltage (measured between terminals UG+ and UG-) has dropped below 50 VDC using a calibrated multimeter before performing any physical installation, wiring, or maintenance.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eMount the drive vertically on a flat, conductive, and grounded metallic backplate to ensure optimal EMC shielding and heat dissipation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the protective earth (PE) conductor to the drive's primary grounding terminal before establishing any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eWire the motor power phases (U, V, W) and connect the resolver or encoder feedback cable to the X2 port.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the 24 VDC auxiliary control power supply and terminate the control signals on the X1 block.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eApply the main 3-phase AC input power and initiate the commissioning sequence via Lenze GDC software.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049698667,"sku":"EVS9324-EPV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9324-epv004-huijna0jdlf.png?v=1776236610","url":"https:\/\/www.plcprotech.com\/pt\/products\/lenze-evs9324-epv004-9300-series-servo-position-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}