{"product_id":"mitsubishi-electric-mds-b-cv-260-mds-b-series-servo-drive-power-supply-module","title":"Mitsubishi Electric MDS-B-CV-260 MDS-B Series Servo Drive Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Providing rectified DC power to MDS Series common bus drive architectures, the \u003cstrong\u003eMitsubishi Electric MDS-B-CV-260\u003c\/strong\u003e is a high-performance power supply unit engineered for CNC and multi-axis servo configurations. This robust converter section converts incoming three-phase AC power into a regulated DC voltage bus, distributing clean, reliable energy directly to paired servo amplifiers and spindle drives. Part of the specialized \u003cstrong\u003eMELDAS\u003c\/strong\u003e system architecture, the unit is optimized for linear and rotary servo applications requiring exceptional power density and operational stability in heavy industrial environments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRegulated DC Bus Output:\u003c\/strong\u003e Delivers stable DC power link to adjacent servo and spindle modules via highly conductive bus bars.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Efficiency Noise Mitigation:\u003c\/strong\u003e Optimized for parallel integration with dual LF-380K line filters to prevent electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCNC Integration:\u003c\/strong\u003e Communicates seamlessly over high-speed optical or serial links to provide real-time status diagnostics to MELDAS control units.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRegenerative Power Management:\u003c\/strong\u003e Features a high-capacity regenerative control system to handle reverse energy spikes during heavy axis deceleration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAutomated machine tool axes and heavy-duty milling applications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-precision linear motor servo networks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMulti-axis industrial robotic cells requiring shared-bus power layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMDS-B-CV-260\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMDS-B Series (MELDAS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eComponent Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConverter \/ Power Supply Section\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSupported Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLinear \/ Rotary Servo Systems\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRecommended Noise Filter\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLF-380K (Two in parallel recommended)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e380 x 280 x 150 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTerminal \/ Connector\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eL1, L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eThree-Phase AC Line Input Power\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eL+, L-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Bus Output to Servo\/Spindle Drive Units\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCN1 \/ CN2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMELDAS CNC System Diagnostics and Control Link\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProtective Earth Ground Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The MDS-B-CV-260 belongs to the legacy generation of MELDAS MDS-B modular drive hardware. It can typically replace older converter models within the same frame configuration, but engineering teams must verify that the corresponding drive units (MDS-B-V1\/V2 series) support the matching control firmware revisions to prevent drive-bus synchronization errors.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  In heavy continuous deceleration operations, ensure that the regenerative discharge system parameters are correctly configured on the CNC side. Overlooking total system regeneration capacity can result in frequent DC overvoltage faults (alarm code 30 or 3A). Ensure cabinet cooling keeps ambient temperatures near the unit below 55 Celsius.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When wiring parallel noise filters, ensure matching lead lengths for both parallel LF-380K filter loops to avoid current imbalance and premature thermal tripping on the filter terminals. Proper shield termination at the ground plate of the electrical enclosure is mandatory for the control signals to prevent communication packet loss on the CNC link.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: HIGH VOLTAGE\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Before executing any wiring or physical maintenance, verify that all three-phase input power lines are fully disconnected and locked out. Allow a minimum of 15 minutes for the DC link capacitors to discharge completely. Always use a calibrated digital multimeter to confirm the voltage between L+ and L- is below 50 VDC prior to handling contacts.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecurely mount the module vertically on a rigid, metallic backplate to ensure proper heat dissipation and low-impedance ground bonding.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the three-phase AC power input to L1, L2, and L3 via designated line filters and contactors in accordance with standard schematic wiring diagrams.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInterconnect the DC bus terminals L+ and L- to the drive units using the manufacturer-provided conductive metal bridge bars, ensuring a torque range matching OEM specifications.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102122762603,"sku":"MDS-B-CV-260","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MDS-B-CV-260-3xaajbhzbv5.png?v=1776137806","url":"https:\/\/www.plcprotech.com\/pt\/products\/mitsubishi-electric-mds-b-cv-260-mds-b-series-servo-drive-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}