{"product_id":"mitsubishi-electric-nz2gf2bn-60da4-cc-link-ie-field-analog-output-module","title":"Mitsubishi Electric NZ2GF2BN-60DA4 CC-Link IE Field Analog Output Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFacilitating high-speed digital-to-analog conversion within CC-Link IE Field networks, the \u003cstrong\u003eMitsubishi Electric NZ2GF2BN-60DA4\u003c\/strong\u003e serves as a high-precision remote device station featuring four independent analog output channels. This module converts 16-bit signed binary digital values into precise voltage or current signals to drive field actuators, control valves, and speed regulators in complex industrial automation architectures.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFour High-Resolution Channels:\u003c\/strong\u003e Supports independent configuration for voltage (-10 to 10 VDC) or current (0 to 20 mADC) outputs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e Features photocoupler isolation between the communication system and analog outputs, alongside transformer isolation between the power supply and analog circuits.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eOutput Short-Circuit Protection:\u003c\/strong\u003e Integrated protection circuitry prevents module damage from field wiring faults or shorted loads.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFlexible Network Topology:\u003c\/strong\u003e Dual RJ45 ports support line, star, and ring topologies on CC-Link IE Field networks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRemovable Terminal Block:\u003c\/strong\u003e Two-piece 18-point terminal block simplifies pre-wiring, commissioning, and hot-swapping procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eProportional control valve positioning in hydraulic and pneumatic systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSpeed reference distribution to variable frequency drives (VFDs).\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSetpoint transmission to SCR power controllers in industrial heating applications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eRemote signal generation for paper, steel, and textile tension control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNZ2GF2BN-60DA4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMain D\/A Converter Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStation Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRemote device station\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAnalog Output Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4 channels (4 points)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDigital Input Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e16-bit signed binary (-16384 to 16383, -288 to 12287, -12288 to 12287)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eVoltage Output Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 to 10 VDC (External load: 1k ohm to 1M ohm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCurrent Output Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 20 mADC (External load: 0 ohm to 600 ohm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOutput Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eShort-circuit protected\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eIsolation (Comm to Analog)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhotocoupler isolation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eIsolation (Power to Analog)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTransformer isolation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eIsolation (Channel to Channel)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNon-isolated\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWithstand Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e500 VAC for 1 minute (between power\/comm and analog outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 connector (CC-Link IE Field)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Supply Terminal\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eM2.5 screw terminal block (Tightening torque: 0.5 to 0.6 Nm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eI\/O Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e18-point two-piece terminal block, M3 screws (Tightening torque: 0.43 to 0.57 Nm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.29 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 1.50 kg;\"\u003e1.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal \/ Pin Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePORT1 \/ PORT2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCC-Link IE Field Network connection (supports line\/ring topologies)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24V, 0V, FG\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModule 24 VDC power input and Frame Ground\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e18-Point Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV+, I+, COM (Channels 1 to 4)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAnalog voltage\/current outputs and common reference lines\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe NZ2GF2BN-60DA4 is specifically designed for CC-Link IE Field networks and is not compatible with legacy CC-Link or CC-Link IE Field Basic protocols. Ensure that the master station PLC is equipped with a compatible CC-Link IE Field Master\/Local module (such as the RJ71GF11-T2 or QJ71GF11-T2) and that the correct CSP+ profile is registered in GX Works2 or GX Works3 prior to network configuration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause there is no channel-to-channel isolation on this module, all analog output common (COM) terminals are internally tied together. Connecting field devices with differing ground potentials can create ground loops, resulting in signal drift, measurement errors, or hardware degradation. If channel-to-channel isolation is required by your application, external signal isolators must be installed between the module outputs and the field devices.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use high-quality double-shielded twisted-pair cables for analog signal runs. Ground the shield at only one end (typically the control panel side) to prevent ground loop currents. Ensure the Frame Ground (FG) terminal on the power supply block is connected to a dedicated class-D ground (100 ohms or less) using a minimum of 2 mm2 wire to minimize high-frequency noise interference from adjacent variable frequency drives.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to commencing any installation, wiring, or maintenance activities, ensure all incoming AC and DC power sources to the control panel are completely de-energized. Verify the absence of voltage using a calibrated digital multimeter. Failure to isolate power can result in severe electrical shock, equipment destruction, or erratic control system behavior.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the module securely to a 35mm DIN rail, ensuring the DIN rail hook is locked in place.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the CC-Link IE Field Ethernet cables to PORT1 and PORT2, ensuring the RJ45 connectors click firmly into position.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the 24VDC module power supply and FG to the dedicated M2.5 terminal block, tightening to the specified torque of 0.5 to 0.6 Nm.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the analog output signal wires to the 18-point removable terminal block, ensuring M3 screws are torqued to 0.43 to 0.57 Nm, then plug the block securely into the module.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102142554475,"sku":"NZ2GF2BN-60DA4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nz2gf2bn-60da4-hmmb1o0hwc3.png?v=1776137911","url":"https:\/\/www.plcprotech.com\/pt\/products\/mitsubishi-electric-nz2gf2bn-60da4-cc-link-ie-field-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}