{"product_id":"omron-e5an-htaa2hbm-500-ac100-240-e5an-h-series-temperature-controller","title":"Omron E5AN-HTAA2HBM-500 AC100-240 E5AN-H Series Temperature Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for high-precision thermal profiling in complex processes, the \u003cstrong\u003eOmron E5AN-HTAA2HBM-500 AC100-240\u003c\/strong\u003e provides advanced ramp\/soak program control and comprehensive system diagnostics. This 1\/4 DIN panel-mount controller features a high-speed sampling rate of 60 milliseconds and universal sensor inputs, enabling highly responsive and accurate control loop performance. Outfitted with advanced event inputs and heater burnout detection, this unit ensures rapid fault isolation in automated industrial heating systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Input Capability:\u003c\/strong\u003e Directly accepts thermocouple, platinum resistance thermometer (RTD), analog voltage, and current loop inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgram Control (Ramp\/Soak):\u003c\/strong\u003e Supports multi-pattern programming for complex thermal profiles and automated processing sequences.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeater Burnout \u0026amp; SSR Failure Diagnostics:\u003c\/strong\u003e Dual-channel current transformer (CT) inputs detect partial heater failure and solid-state relay faults before process failure occurs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThree-Color Display:\u003c\/strong\u003e Large, highly visible digital process variable (PV) display that changes color (red, green, yellow) based on status or alarm thresholds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Physical Build:\u003c\/strong\u003e standard 96 x 96 mm form factor with an IP66 rated front faceplate for dust and water resistance in harsh plant environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial heat treatment furnaces, kilns, and multi-zone ovens.\u003c\/li\u003e\n  \u003cli\u003ePlastic extrusion machines, blow molders, and injection molding units.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor fabrication chambers requiring precise thermal ramping.\u003c\/li\u003e\n  \u003cli\u003ePasteurizers, autoclaves, and packaging lines in food processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eE5AN-HTAA2HBM-500 AC100-240\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eControl Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eProgram Type (Ramp\/Soak) \/ Single Setpoint (Selectable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10 VA maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eBezel Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e96 x 96 mm (1\/4 DIN)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePanel Depth\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e78 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eControl Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRelay (SPST-NO, 250 VAC, 3 A resistive load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHeater Burnout Entrances\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 channels (supports E54-CT1 and E54-CT3 sensors)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAuxiliary Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3 auxiliary relay outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEvent Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eYes (M-type expansion card functionality included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 to +55 degC (no icing or condensation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.31 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.5 kg (with standard structural protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections \u0026amp; Interface Mapping\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left; font-weight: bold;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eTerminal Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eSignal \/ Function Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e1 \u0026amp; 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePower Supply Inputs (100 to 240 VAC, neutral\/line)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e11 \u0026amp; 12\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eControl Output 1 (Relay output, normally open)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e25 \u0026amp; 26\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eHeater Burnout \/ CT1 \u0026amp; CT2 Sensor Inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e31, 32, 33\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUniversal Temperature Sensor Inputs (Thermocouple \/ RTD \/ Analog Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The \"HT\" designation denotes a program-capable controller. When swapping with standard \"H\" models (such as E5AN-HAA2HBM), verify that program ramp\/soak profiles are deactivated or convert them back to a static setpoint. Ensure the auxiliary output assignments match exactly, as the E5AN-H series features dedicated mapping configurations.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e When utilising the Heater Burnout (HB) detection function, set the control output cycle time to at least 1 second when using a solid-state relay. Rapid switching below 1 second can result in false heater burnout alarms because the controller's internal CT measurement routine requires a minimum duration of current flow to evaluate the load current.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e In high-noise electrical panels containing high-power AC drives, run the temperature sensor input lines using twisted-shielded pair cables. Earth the shield at the control panel chassis ground plate only. For long RTD sensor lines, configure the input filter time constant parameter (INF) to minimize process variable fluctuations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to attempting any physical installation, mounting, or wiring modifications on this controller, verify that the main power supply and all associated control loop inputs\/outputs are completely de-energized. Failure to isolate power can result in electrical shock or catastrophic damage to the universal input circuitry.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInsert the E5AN controller body through the 92 x 92 mm panel cutout from the front of the enclosure.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSlide the provided mounting adapters along the side tracks of the housing from behind the panel until they click securely against the panel surface. Tighten the mounting screws evenly to maintain the front panel IP66 environmental seal.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWire the input sensor, control outputs, and power lines according to the specified terminal diagram. Use crimped fork terminals or ring terminals to ensure robust mechanical connections.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077922644331,"sku":"E5AN-HTAA2HBM-500 AC100-240","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/E5AN-HTAA2HBM-500-AC100-240-fog52xw5tvs.png?v=1775733743","url":"https:\/\/www.plcprotech.com\/pt\/products\/omron-e5an-htaa2hbm-500-ac100-240-e5an-h-series-temperature-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}