{"product_id":"omron-ns10-tv01-v2-ns-series-programmable-terminal","title":"Omron NS10-TV01-V2 NS Series Programmable Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to act as a central operator interface within Sysmac system topologies, the \u003cstrong\u003eOmron NS10-TV01-V2\u003c\/strong\u003e HMI module offers exceptional visualization and touch control for demanding automation setups. This 10.4-inch active-matrix TFT display features integrated communication capabilities, enabling reliable, high-speed interaction with PLCs, motion controllers, and variable frequency drives on the plant floor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Visibility TFT Display:\u003c\/strong\u003e Crisp 10.4-inch display utilizing an energy-efficient LED backlight with wide viewing angles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVGA Resolution:\u003c\/strong\u003e High-density 640 x 480 pixel grid optimizes screen real estate for complex graphical plant layouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative Ethernet Port:\u003c\/strong\u003e Supports high-speed communications, project uploads\/downloads, and remote web-based monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Construction:\u003c\/strong\u003e Durable ivory enclosure engineered to resist oil, chemicals, and physical impacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Power Envelope:\u003c\/strong\u003e Maximum 25 W power consumption on a standard industrial 24 VDC bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eAssembly and manufacturing packaging lines.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater chemical dosing and level monitoring.\u003c\/li\u003e\n  \u003cli\u003eHVAC control and environmental chamber automation systems.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis motion control configuration and diagnostic stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNS10-TV01-V2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNS Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDisplay Size \u0026amp; Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10.4-inch TFT LED Backlight\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e640 x 480 dots (VGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eYes (10\/100 Base-TX RJ45)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCase Color\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIvory\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRated Power Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e25 W maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAmbient Storage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: -0.75rem;\"\u003e-20 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAmbient Operating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e35% to 85% (0 to 40 degC), 35% to 60% (40 to 50 degC) non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Atmosphere\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNo corrosive gases\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.3 kg maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eConnector \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 interface for PLC communications and remote host connections.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSerial Port A\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRS-232C D-sub 9-pin connector for direct PLC link or legacy programming.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSerial Port B\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRS-232C D-sub 9-pin connector for auxiliary communication loops.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eType-A for external storage; Type-B for PC-to-HMI project transfers.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe NS10-TV01-V2 completely replaces older NS10-TV01 (non-V2) models. When upgrading, project files written in CX-Designer must be reconfigured in system properties to target the \"V2\" system hardware to ensure perfect touch-coordinate registration and display driver alignment.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating the unit continuously above 40 degC without adequate ventilation in sealed enclosures may accelerate LED backlight degradation. Ensure panel layouts contain passive or active air circulation paths to keep ambient cabinet temperatures well below the 50 degC maximum limit.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent grounding loops and electrical noise from distorting touchscreen responsiveness, always route the 24 VDC power supply using shielded twisted-pair cables. Ensure the HMI functional ground (FG) pin is wired directly to the single-point system cabinet earth bar using a dedicated, low-impedance copper conductor.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to attempting any installation, physical placement, or electrical wiring modifications, ensure that all main incoming AC and DC control voltages to the enclosure are completely isolated. Confirm electrical zero with a calibrated digital multimeter before handling terminal connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eCut a standard rectangular opening in the enclosure door matching the panel cutout dimensions provided in the Omron installation manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePosition the watertight rubber gasket flat and centered around the HMI bezel flange to ensure a proper IP65 environmental seal against moisture ingress.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the HMI terminal through the cutout and secure it in place from behind using the supplied mounting brackets, tightening the screws to the specified torque range of 0.5 to 0.6 Nm.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 VDC power supply wires and functional ground to the terminal block, then interface the RJ45 Ethernet link cable with the controller network switch.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077907898731,"sku":"NS10-TV01-V2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ns10-tv01-v2-hodsybfo2hs.png?v=1775733900","url":"https:\/\/www.plcprotech.com\/pt\/products\/omron-ns10-tv01-v2-ns-series-programmable-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}