{"product_id":"omron-nx-da2603-nx-series-analog-output-unit","title":"Omron NX-DA2603 NX Series Analog Output Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDelivering precise voltage control within the Sysmac automation platform, the Omron NX-DA2603 analog output unit provides reliable high-density analog signal generation in a space-saving 12 mm form factor. Designed for seamless integration with NX-series CPU Units or EtherCAT Coupler Units, this module features a 2-point output capacity operating over a -10 to +10 V range. Utilizing the optimized Free-Run refreshing method, the module ensures steady signal performance across continuous processing demands while maintaining robust galvanic isolation from the system bus to protect sensitive upstream logic controllers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDual-point voltage output (-10 to +10 V) with independent channel configuration.\u003c\/li\u003e\n  \u003cli\u003eFree-Run refreshing mechanism for stable, continuous signal conversion.\u003c\/li\u003e\n  \u003cli\u003eIntegrated TS status LED diagnostic indicator for immediate field operational checks.\u003c\/li\u003e\n  \u003cli\u003eHigh-integrity isolation barrier utilizing power transformers and digital signal isolators.\u003c\/li\u003e\n  \u003cli\u003eUltra-slim 12 mm housing profile maximizing din-rail spacing inside compact control enclosures.\u003c\/li\u003e\n  \u003cli\u003eToolless push-in Plus terminal block system for rapid, vibration-resistant field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eProportional control of hydraulic valves and pneumatic pressure regulators.\u003c\/li\u003e\n  \u003cli\u003eSpeed reference commanding for variable frequency drives (VFDs) and servo controllers.\u003c\/li\u003e\n  \u003cli\u003eAnalog input retransmission to external data acquisition and plant monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eSetpoint distribution to localized temperature control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNX-DA2603\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSysmac NX Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOutput Points\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 points\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOutput Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 to +10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eI\/O Refreshing Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFree-Run refreshing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eIsolation Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBetween input and NX bus: Power = Transformer, Signal = Digital isolator (No channel-to-channel isolation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInsulation Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20 MOhm minimum between isolated circuits (at 100 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDielectric Strength\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e510 VAC between isolated circuits for 1 minute (leakage current: 5 mA max)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eI\/O Power Supply Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSupply from the NX bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 mm x 71 mm x 100 mm (Calculated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING: electrical shock hazard\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c; font-size: 0.95rem;\"\u003eEnsure the main power supplies to both the NX-bus and the field devices are completely de-energized before mounting, removing, or wiring the module. Failure to observe this protocol can cause irreversible damage to the internal logic components or unexpected field device behavior.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; font-size: 0.85rem;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eAlign the module side-connecting guides with the adjacent NX unit on the DIN rail track.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; font-size: 0.85rem;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eSlide the NX-DA2603 firmly onto the DIN rail until you hear an audible click, indicating the bus connector is fully locked into position.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; font-size: 0.85rem;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eWire signal cables using ferrules into the Push-in Plus terminals. Secure signal shielding to a functional ground bar to minimize high-frequency noise interference.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077935489387,"sku":"NX-DA2603","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx-da2603-vnfywk0zjwy.png?v=1775733967","url":"https:\/\/www.plcprotech.com\/pt\/products\/omron-nx-da2603-nx-series-analog-output-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}