{"product_id":"rps6u-200-582-500-013-vibro-meter-vm600-rack-power-supply-110-230-vac","title":"RPS6U 200-582-500-013 Fonte de Alimentação para Rack Vibro-Meter VM600 (110\/230 VAC)","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U 200-582-500-013 (RPS6U)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé o módulo principal de conversão de energia AC para DC para o sistema de proteção de máquinas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter VM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Projetado para ambientes industriais de alta disponibilidade, esta fonte de alimentação montada em rack de 6U converte a rede AC padrão da planta (110\/230 VAC) em tensões DC reguladas necessárias para o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e e vários cartões de E\/S. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetado com alta eficiência e baixa emissão eletromagnética, garantindo que a eletrônica sensível de monitoramento de vibração receba energia \"limpa\", livre de interferências da rede elétrica, o que é crucial para evitar desligamentos falsos em aplicações de geração de energia e petroquímica.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhes)\u003c\/h3\u003e\n\u003cp\u003eA variante\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-582-500-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé a versão AC de alta tensão, oferecendo opções versáteis de instalação para padrões industriais globais.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEntrada AC Universal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePossui faixa de entrada auto-sensível ou selecionável por jumper, permitindo operar perfeitamente tanto em 110 VAC (América do Norte\/Japão) quanto em 230 VAC (Europa\/Ásia).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuporte à Redundância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA arquitetura do rack VM600 permite a instalação de duas unidades\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eem configuração redundante. Nesse arranjo, as unidades compartilham a carga; se uma falhar, a outra assume instantaneamente a carga total sem interromper as funções de proteção da máquina.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnóstico Interno:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitora os níveis de tensão de saída e a temperatura interna. Comunica seu status de saúde via backplane do VM600 para o cartão\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, permitindo alertas de manutenção preditiva antes que ocorra uma falha de energia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCircuito de Proteção:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipado com proteção contra sobretensão, sobrecorrente e curto-circuito, protegendo os caros módulos de processamento do rack contra falhas elétricas externas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRPS6U 200-582-500-013\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuíça\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110\/230 VAC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequência de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 a 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensões de Saída\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC, +12 VDC, -12 VDC (Padrão do Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 a 65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFormato\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack VME 6U Padrão\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePosso misturar um RPS6U AC e um RPS6U DC no mesmo rack VM600?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. O backplane do VM600 é projetado para aceitar alimentação redundante de diferentes fontes. Usar um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-582-500-013 (AC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee uma versão DC (por exemplo, 24 VDC) oferece o mais alto nível de confiabilidade, protegendo o sistema contra a perda de um barramento de energia específico.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO que indica um LED vermelho sólido \"Fault\" no painel frontal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUm LED vermelho geralmente indica uma tensão de saída fora da tolerância ou uma condição interna de superaquecimento. Verifique o consumo total de energia do rack (cartões em excesso) ou certifique-se de que os ventiladores do rack estão funcionando e os filtros de ar estão limpos.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExiste um slot específico para o RPS6U?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEm um rack VM600 padrão, as fontes de alimentação\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esão instaladas nos slots de energia designados à extrema esquerda ou extrema direita do rack, separadas dos cartões de medição e CPU.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiação Redundante:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara verdadeira redundância, assegure que cada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseja alimentado por um circuito de rede diferente (por exemplo, UPS A e UPS B). Ligar ambas as unidades ao mesmo disjuntor anula o propósito da arquitetura de fonte de alimentação dupla.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento para Segurança:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO chassi do rack deve estar firmemente conectado ao terra de proteção (PE). O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edepende do caminho de aterramento do rack para drenar EMI e proteger contra vazamento interno de alta tensão.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEspaço para Ventilação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRacks de alta potência geram calor significativo. Garanta um espaço mínimo de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1U (44,45 mm)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evazio acima e abaixo do rack VM600 se nenhum ventilador ativo for usado, ou verifique se o ventilador está puxando o ar efetivamente através dos dissipadores de calor do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U 200-582-500-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ese destaca pelo seu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlto MTBF (Tempo Médio Entre Falhas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee seu papel em sistemas com classificação SIL. Como a fonte de alimentação é o único componente compartilhado por todos os cartões em um rack, sua confiabilidade é fundamental. A Vibro-Meter utiliza capacitores industriais e componentes magnéticos robustos, classificados para operação contínua a 65 °C, garantindo que o sistema\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Instrumentação Supervisória de Turbinas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epermaneça online mesmo nas condições de calor ambiente elevado de um convés de turbina.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695206429035,"sku":"SIM-275A 200-582-500-013","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-vm600-rps6u-sim-275a-200-582-500-013-power-supply-module-m50txdanj0i_d47c6185-4f1e-4a75-a1e0-34850c27ff58.jpg?v=1766130702","url":"https:\/\/www.plcprotech.com\/pt\/products\/rps6u-200-582-500-013-vibro-meter-vm600-rack-power-supply-110-230-vac","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}