{"product_id":"s3960-244-127-000-017-vibro-meter-vibration-monitoring-interface-unit","title":"S3960 244-127-000-017 Unidade de Interface de Monitoramento de Vibração Vibro-Meter","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960 244-127-000-017 (S3960)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma unidade especializada de interface de sinal e separação galvânica dentro do ecossistema\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVM600. Projetado para aplicações de alta integridade em\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Instrumentação Supervisória de Turbinas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, esta unidade fornece o isolamento elétrico essencial e o condicionamento de sinal necessários para transmitir dados de vibração de ambientes de campo severos para a sala de controle. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé especificamente desenvolvido para lidar com sinais dinâmicos de alta frequência provenientes de acelerômetros e sondas de proximidade, garantindo que loops de terra e interferências eletromagnéticas não comprometam a precisão da lógica de proteção de máquinas em usinas de energia, refinarias e plataformas offshore.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhada)\u003c\/h3\u003e\n\u003cp\u003eA designação\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e244-127-000-017\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresenta uma versão de alta especificação da série S3960, frequentemente compatível com as especificações da série\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI 127\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara modularidade.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolamento Galvânico Tríplice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEsta unidade oferece isolamento independente entre a entrada (lado do sensor), saída (lado do rack) e a fonte de alimentação. Essa arquitetura é fundamental para proteger as placas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600 MPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtra surtos elétricos do lado do campo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFidelidade do Sinal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOtimizado para resposta em frequência de banda larga, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emantém linearidade de fase de DC até 20 kHz, tornando-o adequado tanto para monitoramento de posição de eixo em baixa velocidade quanto para análise de vibração de engrenagens em alta frequência.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção contra Explosão:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpera como um \"Aparelho Associado\", o que significa que pode ser instalado em área segura para interfacear com transdutores intrinsecamente seguros (Ex i) localizados em áreas perigosas Zona 0 ou Zona 1.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento de Energia:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegula e filtra a alimentação de 24 VDC para fornecer energia \"limpa\" aos condicionadores de sinal de campo (ex.: IQS 450), minimizando o ruído da cadeia de medição.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS3960 244-127-000-017\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuíça\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForça de Isolamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4000 Vrms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Sinal de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTensão ou Corrente (dependente do transdutor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Alimentação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 a 70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEstilo de Montagem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrilho DIN 35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensões\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGabinete modular compacto (aprox. 110 x 22 x 100 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo o S3960 244-127-000-017 difere de um isolador industrial padrão?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIsoladores padrão geralmente são limitados a sinais DC de 4-20 mA. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma interface \"de alta velocidade\" capaz de transmitir formas de onda AC dinâmicas (sinais de vibração) sem atenuação ou deslocamento de fase, o que é obrigatório para ferramentas de diagnóstico como a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAnálise de Órbita\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso usar o S3960 para sinais de vibração e temperatura?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmbora projetado principalmente para sinais dinâmicos (vibração\/deslocamento), o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epode ser usado para sinais quase estáticos se as faixas de tensão de entrada forem compatíveis. No entanto, para entradas de RTD ou termopar, geralmente é preferível um transmissor de temperatura dedicado.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é o significado do sufixo A2-B02 frequentemente associado a esta peça?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO sufixo A2-B02 indica a calibração específica do ganho de saída e o kit de montagem mecânica. Isso garante que a unidade seja uma substituição \"plug and play\" para instalações existentes de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI 127\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eou\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eem gabinetes padronizados.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparação da Fiação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMantenha uma distância mínima de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eentre a fiação azul intrinsecamente segura (lado do sensor) e a fiação preta\/cinza não intrinsecamente segura (lado do rack). Use dutos de cabos separados para cumprir os padrões de segurança ATEX\/IECEx.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento da Blindagem:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA blindagem do cabo do sensor deve ser terminada no terminal de blindagem designado da unidade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Certifique-se de que o trilho DIN esteja conectado ao terra mestre do instrumento para fornecer um caminho eficaz para EMI de alta frequência.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsiderações sobre Queda de Tensão:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAo calcular o comprimento máximo do cabo entre o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee o sensor de campo, leve em conta a queda de tensão interna da unidade (tipicamente cerca de 1V). Para percursos muito longos (\u0026gt;300m), assegure que a tensão de alimentação no condicionador de campo permaneça dentro da faixa especificada de -18 a -30 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS3960 244-127-000-017\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé preferido pelos engenheiros de campo por sua classificação de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMTBF (Tempo Médio Entre Falhas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eque ultrapassa 500.000 horas. No contexto de uma lógica de alarme \"Trip-Multiply\" ou \"Perigo\", a confiabilidade desta placa de interface é fundamental. Seu resfriamento passivo e a ausência de software interno o tornam imune a bugs de firmware ou travamentos de processador que podem afetar isoladores digitais mais baratos, proporcionando um caminho de segurança \"puramente hardware\" para máquinas críticas.\u003c\/p\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695208788331,"sku":"S3960 244-127-000-017","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-s3960-244-127-000-017-vibration-monitoring-system-g3sww4kwpfd_314383f2-d86d-46ba-8bd1-493073bb573f.jpg?v=1766130769","url":"https:\/\/www.plcprotech.com\/pt\/products\/s3960-244-127-000-017-vibro-meter-vibration-monitoring-interface-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}