{"product_id":"schneider-electric-140xts01206-modicon-quantum-cable-assembly","title":"Schneider Electric 140XTS01206 Modicon Quantum Cable Assembly","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to streamline point-to-point wiring in high-density control enclosures, the \u003cstrong\u003eSchneider Electric 140XTS01206\u003c\/strong\u003e establishes a secure, low-resistance connection interface for Modicon Quantum digital modules. This heavy-duty cable assembly simplifies the integration of digital I\/O modules into legacy and active control architectures, minimizing manual termination errors and accelerating commissioning timelines.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003ePre-terminated with a robust Modicon Quantum I\/O connector to ensure a gas-tight, vibration-resistant interface.\u003c\/li\u003e\n  \u003cli\u003eGenerous 1.8-meter (6-foot) length accommodates complex routing paths across standard industrial enclosures.\u003c\/li\u003e\n  \u003cli\u003eHigh-power configuration (HP CF ASSY) designed to handle digital signal transitions with minimal voltage drop.\u003c\/li\u003e\n  \u003cli\u003eIntegrated strain relief mechanism within the connector hood to protect internal conductors from physical stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eModicon Quantum PLC system expansions and hardware migrations.\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial control panels requiring pre-fabricated wiring harnesses to maintain high signal integrity.\u003c\/li\u003e\n  \u003cli\u003eRetrofitting legacy automation systems where rapid, plug-and-play I\/O deployment is critical to minimizing downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e140XTS01206\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModicon Quantum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDigital Module Cable Accessory\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.8 meters (6 feet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eQuantum I\/O Connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out (Legacy Support)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFrance\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85444290\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.32 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e30.0 x 32.5 x 5.8 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The 140XTS01206 is engineered specifically for Modicon Quantum digital I\/O modules. When replacing legacy assemblies, verify that the terminal block pin configuration matches your specific module's hardware revision, as some legacy modules require distinct terminal block depths.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e Avoid routing this cable assembly adjacent to high-voltage motor supply lines or variable frequency drives (VFDs) without adequate metallic shielding separation. Due to its 1.8-meter length, excessive coiling of unused cable can introduce parasitic inductance; route in a sweeping \"S\" pattern rather than tight loops.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e During commissioning, ensure the connector's retaining screws are hand-tightened to prevent back-out under low-frequency structural vibration. Always verify continuity from the module terminal to the field termination block before energizing the system.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e \u003cspan style=\"color: #9b2c2c;\"\u003eBefore installing or removing any cable assembly, ensure all primary and auxiliary power sources to the PLC rack and field devices are completely de-energized. Failure to do so can result in electrical arcing, module damage, or severe personal injury.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInspect the cable assembly and connector pins for any physical damage, bent pins, or contamination before insertion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eAlign the connector with the interface port on the Modicon Quantum digital module and push firmly until fully seated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSecure the connector locking screws to the specified torque to maintain physical integrity and electrical contact under vibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eRoute the cable through standard wire ducts, ensuring the minimum bend radius is maintained to prevent internal conductor fatigue.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104538452331,"sku":"140XTS01206","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140xts01206-cfk4hsi5grh.png?v=1776159671","url":"https:\/\/www.plcprotech.com\/pt\/products\/schneider-electric-140xts01206-modicon-quantum-cable-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}