{"product_id":"schneider-electric-171cbu98090-modicon-momentum-processor-module","title":"Schneider Electric 171CBU98090 Modicon Momentum Processor Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to integrate seamlessly into distributed control architectures, the \u003cstrong\u003eSchneider Electric 171CBU98090\u003c\/strong\u003e provides high-performance processing capabilities for Modicon Momentum I\/O systems. This Unity M1E processor module features versatile communication options, including embedded Ethernet, USB, and serial interfaces, making it an efficient choice for modernizing legacy control systems or implementing new industrial automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Protocol Connectivity:\u003c\/strong\u003e Equipped with an RJ45 Ethernet port, a mini-B USB port, and a non-isolated RS232\/RS485 serial port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnity Pro Compatibility:\u003c\/strong\u003e Fully compatible with Unity Pro and EcoStruxure Control Expert programming environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Space-saving design that mounts directly onto Modicon Momentum I\/O bases.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Diagnostics:\u003c\/strong\u003e Front-panel LED indicators provide real-time status of processor run state, errors, and network activity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDistributed control systems (DCS) in water and wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveyor systems, and logistics automation.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and assembly line control.\u003c\/li\u003e\n  \u003cli\u003eRemote telemetry units (RTUs) for infrastructure and utility monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e171CBU98090\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModicon Momentum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProcessor Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnity M1E Processor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x Ethernet TCP\/IP (RJ45), 1 x USB (Mini-B), 1 x RS232\/RS485 (RJ45)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMemory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e512 KB (Program\/Data)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProgramming Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnity Pro \/ EcoStruxure Control Expert\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% to 95% non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.24 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20.7 x 11.0 x 7.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; width: 30%;\"\u003ePort Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnector \/ Interface\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupported Protocols\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEthernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 (10\/100 Base-TX)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModbus TCP\/IP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSerial\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 (Non-isolated RS232\/RS485)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModbus RTU \/ Modbus ASCII\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProgramming\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSB Type Mini-B\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLocal Configuration \/ Programming\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 171CBU98090 serves as a direct upgrade path for older Concept-based Modicon Momentum processors (such as the 171CCC96020 or 171CCC98020). It allows users to transition their existing Momentum I\/O hardware into the modern Unity Pro \/ EcoStruxure Control Expert software platform without replacing field wiring or I\/O bases.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eNote that the onboard RS232\/RS485 serial port is non-isolated. When connecting to long-distance serial networks or devices located in electrically noisy environments, the use of an external optical isolator is highly recommended to prevent ground loop currents from damaging the processor's communication interface.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBefore deploying the processor to an active network, configure the IP address parameters using a BootP\/DHCP server or directly via the USB programming interface. Ensure that shielded twisted-pair (STP) Cat5e or Cat6 cabling is used for the Ethernet connection, and verify that the shield is properly grounded at the switch end to minimize electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all electrical power sources before mounting, removing, or wiring the processor module. Failure to de-energize the system can result in severe electrical shock, equipment damage, or unintended machine operation.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eAlign the processor module's interface connector with the mating connector on the Modicon Momentum I\/O base unit.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003ePress the processor firmly onto the I\/O base until the side locking tabs click securely into place.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eMount the combined assembly onto a standard 35mm DIN rail, ensuring the grounding clip makes solid contact with the rail.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eConnect the communication cables (Ethernet, Serial, or USB) to their respective ports, ensuring proper strain relief is applied.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eApply system power and verify the boot sequence via the front-panel LED status indicators.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104505848171,"sku":"171CBU98090","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/171cbu98090-wc5rbf0arr1.png?v=1776159758","url":"https:\/\/www.plcprotech.com\/pt\/products\/schneider-electric-171cbu98090-modicon-momentum-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}