{"product_id":"schneider-electric-tsxdez08a4-modicon-tsx-micro-ac-discrete-input-module","title":"Schneider Electric TSXDEZ08A4 Modicon TSX Micro AC Discrete Input Module","description":"\u003ch1\u003eSchneider Electric TSXDEZ08A4 Modicon TSX Micro AC Discrete Input Module\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for seamless integration with Modicon TSX Micro programmable logic controllers, the \u003cstrong\u003eTSXDEZ08A4\u003c\/strong\u003e provides reliable signal detection for industrial automation environments. This high-density \u003cstrong\u003eAC discrete input module\u003c\/strong\u003e features 8 independent channels designed to monitor alternating current status signals from field devices such as limit switches, pushbuttons, and sensors. Its robust construction ensures stable operation and precise signal conditioning within demanding electrical control panels, making it an essential component for maintaining or upgrading legacy Modicon TSX Micro control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 8 discrete AC input channels for comprehensive field device monitoring.\u003c\/li\u003e\n  \u003cli\u003eEngineered specifically for compatibility with the Schneider Electric Modicon TSX Micro PLC platform.\u003c\/li\u003e\n  \u003cli\u003eCompact modular form factor optimizes space utilization within electrical enclosures.\u003c\/li\u003e\n  \u003cli\u003eReliable signal isolation protects sensitive control electronics from electrical noise and transients.\u003c\/li\u003e\n  \u003cli\u003eEasy slot-in installation minimizes system downtime during maintenance or expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturing assembly lines and machinery control.\u003c\/li\u003e\n  \u003cli\u003eMotor control centers (MCC) and pump control panels.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eLegacy system retrofits and industrial automation upgrades.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eTSXDEZ08A4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003eModicon TSX Micro\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Channels\u003c\/strong\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Type\u003c\/strong\u003e\n      \u003ctd\u003eAC (Alternating Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e1.08 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions\u003c\/strong\u003e\n      \u003ctd\u003e18.00 cm x 25.50 cm x 5.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85389091\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure safe and reliable operation of the TSXDEZ08A4 module, adhere to the following engineering practices:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect all power sources to the PLC rack and field wiring before inserting, removing, or wiring the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Align the module with the designated slot guides on the Modicon TSX Micro backplane and slide it in until it is fully seated and locked.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route high-voltage AC input wiring separately from low-voltage DC signal lines and communication cables to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the PLC rack chassis is properly grounded in accordance with local electrical codes and standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104566632811,"sku":"TSXDEZ08A4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxdez08a4-kr411iclkxx.png?v=1776163880","url":"https:\/\/www.plcprotech.com\/pt\/products\/schneider-electric-tsxdez08a4-modicon-tsx-micro-ac-discrete-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}