{"product_id":"siemens-6av7613-0ab22-0aj0-simatic-panel-pc-670","title":"Siemens 6AV7613-0AB22-0AJ0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6AV7613-0AB22-0AJ0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e and is powered by a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e. It is configured with \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e, and an integrated CD-ROM drive. The system operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and comes pre-installed with the Windows NT 4.0 English operating system. Please note this model is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    12-inch TFT color display for process visualization.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Powered by an Intel Pentium III 500 MHz processor.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Equipped with 128 MB RAM and a 20 GB hard disk drive.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Includes an integrated CD-ROM drive for software installation.\n  \u003c\/li\u003e\n    \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Operates on a nominal 24 V DC industrial power supply.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Pre-loaded with Microsoft Windows NT 4.0 (English).\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Machine-level operator control and monitoring.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Process visualization and data acquisition in manufacturing plants.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    SCADA client terminals in industrial networks.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n    Replacement unit for maintaining existing automated systems.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7613-0AB22-0AJ0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePentium III, 500 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows NT 4.0 English\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e45 cm x 38 cm x 22 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 15px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 15px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Risk of electric shock and equipment damage. All installation and maintenance activities must be performed by qualified personnel with the main electrical supply to the cabinet de-energized and locked out (LOTO).\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    Ensure the control cabinet is completely de-energized and verified to be at a zero-volt state before beginning work.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    Verify the panel cutout dimensions match the requirements for the PC 670 chassis. Prepare the mounting surface, ensuring it is clean and flat.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    Carefully insert the Panel PC into the cutout from the front of the enclosure. Ensure the front bezel gasket is properly seated against the panel surface to maintain ingress protection.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    From the rear of the unit, install and tighten the mounting clamps evenly in a cross-pattern to secure the chassis firmly in place. Do not overtighten.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n    Connect the 24 V DC power supply wiring to the designated terminals, observing correct polarity. Ensure the power source is stable and correctly rated.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e6\u003c\/span\u003e\n    Connect all required communication cables (e.g., Ethernet, serial) and peripherals. Ensure a secure connection to the chassis ground terminal.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 35px; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e7\u003c\/span\u003e\n    After a final check of all connections, remove the lockout\/tagout device and re-energize the main cabinet supply to power on and test the Panel PC.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715805933931,"sku":"6AV7613-0AB22-0AJ0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0ab22-0aj0-klmskh1qydm_934fa257-7545-4d94-8c44-c59642c10c05.jpg?v=1767071282","url":"https:\/\/www.plcprotech.com\/pt\/products\/siemens-6av7613-0ab22-0aj0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}