{"product_id":"siemens-6av7874-0dc20-1ac0-simatic-panel-pc-677b","title":"Siemens 6AV7874-0DC20-1AC0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6AV7874-0DC20-1AC0\u003c\/strong\u003e is a SIMATIC Panel PC 677B, designed for industrial human-machine interface (HMI) and control applications. This robust panel PC features a 17-inch touch display with a resolution of 1280 x 1024 pixels. It is equipped with a Core 2 Duo T5500 processor operating at 1.66 GHz, 1 GB of DDR2 RAM, and a 160 GB SATA hard disk drive. Connectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports (plus a front-side USB interface), and one serial (COM1) port. An integrated DVD+-R+-RW drive is included, alongside a PROFIBUS\/MP interface with 2 MB of buffered SRAM. The unit is powered by a 110\/230 V AC supply with NAMUR support and comes with a UK power supply cable. It operates with Windows XP Professional MUI, supporting multiple languages.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e17-inch touch display with 1280 x 1024 resolution\u003c\/li\u003e\n\u003cli\u003eCore 2 Duo T5500 processor, 1.66 GHz with 2 MB SLC\u003c\/li\u003e\n\u003cli\u003e1 GB DDR2 RAM\u003c\/li\u003e\n\u003cli\u003e160 GB SATA HDD (3.5\")\u003c\/li\u003e\n\u003cli\u003eIntegrated DVD+-R+-RW optical drive\u003c\/li\u003e\n\u003cli\u003eTwo 10\/100\/1000 Mbit\/s Ethernet interfaces\u003c\/li\u003e\n\u003cli\u003eFour USB V2.0 ports and one front-side USB interface\u003c\/li\u003e\n\u003cli\u003eOne serial (COM1) port\u003c\/li\u003e\n\u003cli\u003ePROFIBUS\/MP interface with 2 MB buffered SRAM\u003c\/li\u003e\n\u003cli\u003eTwo PCI expansion slots\u003c\/li\u003e\n\u003cli\u003e110\/230 V AC power supply with NAMUR functionality\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows XP Professional MUI (Multi-User Interface)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens SIMATIC Panel PC 677B is suitable for a wide range of industrial applications requiring robust computing and visualization capabilities. Typical uses include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMachine control and operation\u003c\/li\u003e\n\u003cli\u003eProcess visualization and monitoring\u003c\/li\u003e\n\u003cli\u003eData acquisition and logging\u003c\/li\u003e\n\u003cli\u003eFactory automation HMI solutions\u003c\/li\u003e\n\u003cli\u003eSupervisory control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSub-Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTouch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1280 x 1024\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore 2 Duo T5500, 1.66 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB SLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 GB DDR2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Disk Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e160 GB SATA HDD 3.5\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0, 1x Front-side USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x COM1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x PCI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNAMUR, UK power supply cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Professional MUI (de,en,fr,es,it,ja,zh,ko)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energization:\u003c\/strong\u003e Ensure all power to the installation area is disconnected and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the panel PC into a suitable panel cutout or enclosure, ensuring adequate clearance for ventilation and cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 110\/230 V AC power supply cable to the designated power input terminal. Verify correct voltage and grounding.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the panel PC chassis to ensure safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e Connect Ethernet cables to the RJ45 ports, USB devices to the USB ports, and serial devices to the COM1 port as required by the application. Ensure proper cable routing to prevent strain and interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP Connection:\u003c\/strong\u003e If utilizing PROFIBUS\/MP, connect the appropriate bus cable to the designated interface, observing correct termination and shielding practices.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure that the panel PC's ventilation openings are not obstructed to maintain proper operating temperature and prevent overheating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e After all connections are verified, re-energize the system and observe for proper boot-up and operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715857052011,"sku":"6AV7874-0DC20-1AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7874-0dc20-1ac0-mrnibrglkta_a5dc91c0-b77f-4e26-ad42-4254cb13acff.jpg?v=1767072872","url":"https:\/\/www.plcprotech.com\/pt\/products\/siemens-6av7874-0dc20-1ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}