{"product_id":"siemens-6es5095-8md03-simatic-s5-compact-unit","title":"Siemens 6ES5095-8MD03 SIMATIC S5 Compact Unit","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe 6ES5095-8MD03 is a SIMATIC S5-95U compact PLC unit from Siemens, engineered for control tasks in demanding industrial environments. This module integrates a \u003cstrong\u003ePROFIBUS-DP slave interface\u003c\/strong\u003e, facilitating direct communication within a distributed control network. Its robust, all-in-one design makes it a reliable component for legacy automation systems requiring proven performance and straightforward integration. The unit is built for long-term operational stability in production and process management applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eCompact, integrated PLC design\u003c\/li\u003e\n\u003cli\u003eBuilt-in PROFIBUS-DP slave interface for network communication\u003c\/li\u003e\n\u003cli\u003ePart of the established Siemens SIMATIC S5 automation family\u003c\/li\u003e\n\u003cli\u003eEngineered for durability in industrial settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eManufacturing and assembly lines\u003c\/li\u003e\n\u003cli\u003eAutomated material handling systems\u003c\/li\u003e\n\u003cli\u003eProcess control in legacy systems\u003c\/li\u003e\n\u003cli\u003ePackaging and sorting machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6ES5095-8MD03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC S5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eS5-95U Compact Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eIntegrated Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePROFIBUS-DP Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePredecessor Part\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6ES5095-8MD02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e1.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e15.5 cm x 15.2 cm x 16.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. All installation and maintenance procedures must be performed by qualified personnel with the main power supply de-energized and locked out (LOTO). Failure to comply can result in severe injury or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely disconnect and lock out all power sources to the control panel or machine. Verify the absence of voltage with a properly rated meter.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Securely mount the compact unit onto the designated DIN rail or panel surface within the enclosure. Ensure adequate clearance for ventilation and cable routing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Grounding:\u003c\/strong\u003e Connect a dedicated protective earth (PE) conductor to the designated grounding terminal on the unit chassis. A low-impedance ground connection is essential for safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eTerminate Wiring:\u003c\/strong\u003e Connect power supply, I\/O, and PROFIBUS-DP communication cables to the correct terminals. Ensure all connections are secure and torqued to specification. Use shielded twisted-pair cabling for the PROFIBUS network.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eSystem Verification:\u003c\/strong\u003e After all connections are made and verified, remove the lockout\/tagout devices and re-apply power. Commission the unit according to project-specific procedures.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716786909547,"sku":"6ES5095-8MD03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es5095-8md03-q0ydrp2ath1_7f7a4c38-c8f8-4d38-a726-783985ee330e.jpg?v=1767089777","url":"https:\/\/www.plcprotech.com\/pt\/products\/siemens-6es5095-8md03-simatic-s5-compact-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}