{"product_id":"siemens-6es7647-6cb06-0aa0-simatic-ipc627c-box-pc","title":"Siemens 6ES7647-6CB06-0AA0 SIMATIC IPC627C Box PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is the Siemens 6ES7647-6CB06-0AA0, a SIMATIC IPC627C series industrial Box PC engineered for reliable operation in demanding automation and process control environments. This unit is powered by an \u003cstrong\u003eIntel Celeron P4505 dual-core processor\u003c\/strong\u003e and features integrated HD graphics. It provides robust connectivity with dual Gigabit Ethernet ports, a PROFIBUS\/MPI interface, and multiple USB 2.0 ports. For system integrity, it includes an onboard RAID controller, watchdog timer, and active temperature and fan monitoring. The system is configured with \u003cstrong\u003e1 GB of DDR3 RAM\u003c\/strong\u003e, a \u003cstrong\u003e250 GB SATA hard drive\u003c\/strong\u003e, and operates on a standard \u003cstrong\u003e24 V DC industrial power supply\u003c\/strong\u003e, making it suitable for direct integration into control cabinets.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcessor: Intel Celeron P4505 (2C\/2T, 1.86 GHz, 2 MB Cache)\u003c\/li\u003e\n  \u003cli\u003eMemory: 1 GB DDR3 1066 DIMM\u003c\/li\u003e\n  \u003cli\u003eStorage: 250 GB SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n  \u003cli\u003eConnectivity: Dual 10\/100\/1000 Mbit\/s Ethernet ports\u003c\/li\u003e\n  \u003cli\u003eFieldbus: Integrated PROFIBUS\/MPI interface (CP 5611-A2 compatible)\u003c\/li\u003e\n  \u003cli\u003eExpansion: Two free PCI slots for additional cards\u003c\/li\u003e\n  \u003cli\u003eSystem Monitoring: Integrated watchdog timer, temperature, and fan monitoring\u003c\/li\u003e\n  \u003cli\u003ePower Supply: 24 V DC input for industrial applications\u003c\/li\u003e\n  \u003cli\u003eOperating System: Pre-installed Windows XP Professional SP3 MUI\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcess visualization and HMI stations\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n  \u003cli\u003eMachine-level control and computing tasks\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES) gateways\u003c\/li\u003e\n  \u003cli\u003eIndustrial network gateways and communication servers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSIMATIC IPC627C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e6ES7647-6CB06-0AA0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIntel Celeron P4505 (2 Cores, 2 Threads, 1.86 GHz, 2 MB Cache, VT)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1 GB DDR3 1066 DIMM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e250 GB HDD SATA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGraphics\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOnboard HD Graphics\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e2 x 10\/100\/1000 Mbit\/s Ethernet RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e4 x USB 2.0 (High Current)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSerial Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1 x COM1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePROFIBUS\/MPI (CP 5611-A2 compatible)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e2 x PCI (free)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRemovable Media\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCompactFlash Drive (front accessible)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIntegrated Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRAID Controller, Watchdog, Temperature\/Fan Monitoring\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e24 V DC Industrial Power Supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWindows XP Professional SP3 MUI (DE, EN, FR, SP, IT)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e6.45 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e28.0 x 33.0 x 31.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e5A992\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Installation must be performed by qualified personnel only. Failure to comply with safety procedures can result in equipment damage, severe injury, or death. Always de-energize the entire control cabinet and apply Lockout\/Tagout (LOTO) procedures before commencing any installation or maintenance work.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely disconnect power to the control panel or mounting location. Verify the absence of voltage using a calibrated multimeter.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Mount the Box PC securely to a stable, vibration-free surface within the control cabinet. Ensure adequate clearance around the unit for ventilation and cable access as per the manufacturer's specifications.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect the chassis grounding terminal to the main protective earth busbar of the cabinet using a low-impedance conductor of the appropriate gauge. This is critical for safety and noise immunity.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated input terminals. Ensure correct polarity (+\/-). Use properly sized wiring and ensure the power source is stable and within the specified voltage range.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Interfaces:\u003c\/strong\u003e Connect all required network (Ethernet, PROFIBUS\/MPI), peripheral (USB), and serial cables. Ensure all connectors are fully seated and secured. Route cables neatly to avoid strain and interference.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eFinal Check and Power-Up:\u003c\/strong\u003e Double-check all connections for correctness and security. Remove all tools and foreign objects from the cabinet. After removing LOTO devices, re-energize the cabinet and verify the PC boots correctly.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716420989291,"sku":"6ES7647-6CB06-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6cb06-0aa0-2hfxsg1nfwc_2a1f0b42-b883-4b60-9321-e743b8f693ab.jpg?v=1767082655","url":"https:\/\/www.plcprotech.com\/pt\/products\/siemens-6es7647-6cb06-0aa0-simatic-ipc627c-box-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}