{"product_id":"siemens-7ml1201-1fe00-sitrans-probe-ultrasonic-level-transmitter","title":"Siemens 7ML1201-1FE00 Transmissor de Nível Ultrassônico SITRANS Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e7ML1201-1FE00\u003c\/strong\u003e is a \u003cstrong\u003eSITRANS Probe\u003c\/strong\u003e ultrasonic level transmitter designed for continuous, non-contact level monitoring of liquids and slurries. This unit provides a measurement range of up to \u003cstrong\u003e5 meters (16.4 ft)\u003c\/strong\u003e and is equipped with a \u003cstrong\u003e3-wire relay output\u003c\/strong\u003e for seamless integration into industrial control systems. Engineered for durability, the transmitter features a \u003cstrong\u003ePVDF copolymer\u003c\/strong\u003e transducer and process connection, ensuring compatibility with a variety of process fluids.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e Ultrasonic non-contact level measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e Up to 5 meters (16.4 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 3-wire relay output configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e PVDF copolymer transducer and process connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Connection:\u003c\/strong\u003e R 2\" (BSPT), EN 10226.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e 24 V DC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Suitable for liquids and slurries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater and wastewater storage tanks.\u003c\/li\u003e\n\u003cli\u003eChemical storage and processing vessels.\u003c\/li\u003e\n\u003cli\u003eSlurry level monitoring in mining or industrial processes.\u003c\/li\u003e\n\u003cli\u003eLiquid level control in confined industrial containers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITRANS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7ML1201-1FE00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 meters (16.40 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR 2\" (BSPT), EN 10226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVDF copolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-wire relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.00 cm x 31.00 cm x 95.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the unit in a vertical position above the medium to be measured to ensure accurate ultrasonic echo returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eObstructions:\u003c\/strong\u003e Ensure the sensor face has a clear, unobstructed line-of-sight to the surface of the medium, avoiding agitators, pipes, or tank walls within the beam path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions:\u003c\/strong\u003e While the unit is robust, avoid mounting in locations subject to extreme vacuum or excessive foam, as these can interfere with ultrasonic wave propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded cabling to minimize electrical interference and ensure the 24 V DC power supply is stable and properly grounded per industrial standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the transducer face to prevent buildup of material that may cause measurement drift or loss of signal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779536747,"sku":"7ML1201-1FE00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/7ml1201-1fe00-fq3ycem0b1f_d32ffed3-6011-499a-86bd-72d3432b2d79.jpg?v=1767089480","url":"https:\/\/www.plcprotech.com\/pt\/products\/siemens-7ml1201-1fe00-sitrans-probe-ultrasonic-level-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}