{"product_id":"siemens-simatic-panel-pc-670-6av7614-0af20-0bh0","title":"Siemens SIMATIC Panel PC 670 6AV7614-0AF20-0BH0","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThis is a SIMATIC Panel PC 670, model 6AV7614-0AF20-0BH0, manufactured by Siemens. It is an industrial computer designed for human-machine interface (HMI) and control applications. This specific configuration features a \u003cstrong\u003e15-inch TFT touch display\u003c\/strong\u003e, a \u003cstrong\u003e300 MHz Celeron processor\u003c\/strong\u003e, \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e with an integrated CD-ROM. The unit is pre-installed with the German language version of Windows NT 4.0 and is supplied with a U.S. mains power cable for operation on 115-230V systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"color: #2d3748; list-style-type: square; padding-left: 20px;\"\u003e\n  \u003cli\u003e15-inch TFT color display with integrated touch functionality\u003c\/li\u003e\n  \u003cli\u003ePowered by a 300 MHz Celeron CPU\u003c\/li\u003e\n  \u003cli\u003eEquipped with 128 MB of system RAM\u003c\/li\u003e\n  \u003cli\u003eIncludes a 40 GB hard drive for local storage\u003c\/li\u003e\n  \u003cli\u003eFeatures a built-in CD-ROM drive\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Windows NT 4.0 operating system (German language)\u003c\/li\u003e\n  \u003cli\u003eSupplied with a U.S. standard mains power cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"color: #2d3748; list-style-type: square; padding-left: 20px;\"\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) for process visualization\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n  \u003cli\u003eMachine control and monitoring terminals\u003c\/li\u003e\n  \u003cli\u003eFactory floor data logging and reporting stations\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6AV7614-0AF20-0BH0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e15-inch TFT Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e40 GB Hard Drive, CD-ROM Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows NT 4.0 (German Language)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e115-230 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded Cable\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eU.S. Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e35.00 x 25.00 x 25.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out (LOTO) before commencing any installation, wiring, or maintenance activities. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    Verify that the panel cutout dimensions match the PC 670's mounting requirements. Ensure the mounting surface is flat, clean, and capable of supporting the unit's weight.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    Insert the Panel PC into the prepared cutout from the front of the enclosure. Secure it evenly from the rear using all provided mounting clamps. Do not overtighten; apply torque uniformly to create a proper seal.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    Connect a dedicated protective earth (PE) or grounding conductor to the designated chassis ground terminal. This connection is critical for safety and noise immunity.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    Connect the mains power cable to a stable, correctly rated power source. Ensure the source voltage matches the 115-230 V range of the unit. Route power cables separately from signal and communication lines to prevent interference.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    Connect all necessary peripheral and communication cables (e.g., Ethernet, serial, USB). Ensure all connectors are fully seated and secured. After installation is complete, power may be restored to the unit.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715894341995,"sku":"6AV7614-0AF20-0BH0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7614-0af20-0bh0-ql5owpgsabw_0d1fcef4-65ec-4a08-8e0d-235514098f7f.jpg?v=1767074151","url":"https:\/\/www.plcprotech.com\/pt\/products\/siemens-simatic-panel-pc-670-6av7614-0af20-0bh0","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}