{"product_id":"sst-pfb-clx-brad-communications-profibus-dp-scanner-for-controllogix","title":"Scanner PROFIBUS DP para ControlLogix SST-PFB-CLX Brad Communications","description":"\u003ch3\u003e\u003cstrong\u003eVisão Geral do Produto e Integração Multi-Protocolo\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST-PFB-CLX (SSTPFBCLX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um módulo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS DP Master\/Scanner\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ede alto desempenho projetado para integrar dispositivos de campo PROFIBUS diretamente na plataforma\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley ControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Desenvolvido pela SST (uma empresa Molex), este módulo atua como uma ponte de comunicação perfeita, permitindo que os processadores ControlLogix controlem e monitorem instrumentos, drives e blocos de E\/S compatíveis com PROFIBUS como se fossem dispositivos nativos EtherNet\/IP. Ao utilizar o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST-PFB-CLX\u003c\/strong\u003e, os engenheiros podem aproveitar o vasto ecossistema de hardware PROFIBUS — predominante nas indústrias europeias e de processos especializados — enquanto mantêm o controle centralizado e o poder de diagnóstico da Arquitetura Integrada da Rockwell Automation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eArquitetura de Hardware e Processamento de Dados\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST-PFB-CLX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eocupa um único slot em qualquer chassi padrão 1756 ControlLogix. Ele é projetado para troca de dados em alta velocidade, utilizando um processador embarcado para gerenciar o ciclo PROFIBUS independentemente da varredura do PLC.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatilidade Master\/Slave:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo pode funcionar como um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMaster DPV0\/DPV1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(controlando até 125 escravos) ou atuar simultaneamente como um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave DP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara outro master, oferecendo máxima flexibilidade em redes hierárquicas complexas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExecução em Alta Velocidade:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuporta todas as taxas de baud padrão PROFIBUS até\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 Mbps\u003c\/strong\u003e, garantindo desempenho determinístico para movimentos de alta velocidade ou ciclos de processo sincronizados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrande Capacidade de Dados:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapaz de mapear até\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e244 bytes de Entrada e 244 bytes de Saída\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epor dispositivo escravo nos tags do controlador ControlLogix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuporte CommDTM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuporta tecnologia FDT\/DTM, permitindo gerenciamento remoto de ativos e configuração de instrumentos de campo (como medidores de vazão ou transmissores) diretamente pelo backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEspecificações Técnicas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSST-PFB-CLX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSST \/ Molex (Parceiro Allen-Bradley)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocolo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePROFIBUS DP-V0 e DP-V1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConector D-Sub Fêmea de 9 pinos (PROFIBUS padrão)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMáximo de Escravos\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 Nós\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTaxa de Baud\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9,6 kbps a 12 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente no Backplane\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5 VDC \/ 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguração\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware SST Console \/ Perfil Add-On (AOP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 60 graus Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso para Envio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1,2 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ Técnico Integrado\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo configuro a rede PROFIBUS para este módulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA configuração é normalmente realizada usando o software\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST Console\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Você importa os\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003earquivos GSD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edos seus dispositivos escravos, define os parâmetros da rede e faz o download da configuração para o módulo via backplane ControlLogix ou pela porta frontal do módulo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO SST-PFB-CLX suporta \"Hot Swapping\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. Como membro da família 1756, ele suporta\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoção e Inserção com Energia (RIUP)\u003c\/strong\u003e. No entanto, remover o módulo resultará na perda imediata da comunicação com todos os 125 escravos PROFIBUS, portanto o sistema deve estar em um estado seguro antes da remoção.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEste módulo suporta mensagens acíclicas (DP-V1)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCom certeza. O módulo suporta operações de leitura\/gravação acíclicas DP-V1. Isso é essencial para alterar parâmetros em tempo real ou realizar diagnósticos profundos em instrumentos inteligentes sem interromper os dados cíclicos de E\/S.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProtocolos de Engenharia e Instalação\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminação e Impedância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGaranta que a rede PROFIBUS esteja corretamente terminada em ambas as extremidades físicas do segmento. Use conectores PROFIBUS padrão com resistores de terminação embutidos. Ajustar o interruptor de terminação para \"ON\" no\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST-PFB-CLX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(se for um nó final) é fundamental para evitar reflexões de sinal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegridade do Cabeamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse apenas cabo PROFIBUS Tipo A Roxo. Mantenha uma distância mínima de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 cm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ede linhas AC de alta potência para evitar interferência eletromagnética (EMI) que possa corromper o fluxo de dados a 12 Mbps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLógica de Endereçamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCada escravo na rede PROFIBUS deve ter um endereço único (\u003cstrong\u003e1 a 125\u003c\/strong\u003e). Evite usar o endereço 0 (geralmente reservado para ferramentas de programação) ou o endereço 126 (padrão de fábrica para muitos dispositivos novos).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eVantagens de Engenharia\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST-PFB-CLX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ese destaca pela sua\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransparência diagnóstica\u003c\/strong\u003e. Ele fornece um registrador de status dedicado dentro do banco de dados de tags ControlLogix que oferece dados de saúde em tempo real para cada escravo na rede. Isso permite que as equipes de manutenção identifiquem instantaneamente um sensor com falha ou um segmento de cabo rompido através do IHM, sem a necessidade de abrir o painel de controle. Ao desacoplar o tempo do PROFIBUS da varredura do PLC, o módulo garante que a rede permaneça estável mesmo se o processador ControlLogix estiver sob alta carga computacional, tornando-o uma solução \"configure e esqueça\" para ambientes de protocolo híbrido.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695192633707,"sku":"SST-PFB-CLX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-sst-pfb-clx-scanner-module-1ztqno3sa5t_c606a589-9e71-4636-9e12-2bd17981312d.jpg?v=1766114688","url":"https:\/\/www.plcprotech.com\/pt\/products\/sst-pfb-clx-brad-communications-profibus-dp-scanner-for-controllogix","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}